鲍谚, 姜久春, 张维戈. 新型直流系统绝缘在线监测方法[J]. 高电压技术, 2011, 37(2): 333-337. Bao Yan, Jiang Jiuchun, Zhang Weige. Novel on-line insulation supervising method for DC system[J]. High Voltage Engineering, 2011, 37(2): 333-337.
[2]
赵梦欣, 陈国峰, 余伟成. 直流系统绝缘监测的直流漏电流法改进方案[J]. 电力系统自动化, 2009, 33(14): 83-88. Zhao mengxin, Chen Guofeng, Yu Weicheng. Modifica- tion of the leakage method for DC system insulation monitoring[J]. Automation of Electric Power Systems, 2009, 33(14): 83-88.
[3]
李立伟, 刘险峰, 刘斌. 基于现场总线的分布式直流系统接地在线监测装置设计[J]. 电力自动化设备, 2006, 26(12): 55-58. Li Liwei, Liu Xianfeng, Liu Bin. Distributed on-line grounding monitoring system for DC system based on field bus[J]. Electric Power Automation Equipment, 2006, 26(12): 55-58.
[4]
张刚, 杜深慧, 王美华, 等. 基于M/T法直流母线绝缘检测系统的研究[J]. 电测与仪表, 2006, 43(8): 10-13. Zhang Gang, Du Shenhui, Wang Meihua, et al. Study on online insulation detection for DC system based on M/T technology[J]. Electrical Measurement & Instru- mentation, 2006, 43(8): 10-13.
[5]
陈元平, 李树君, 张玉奎. 绝缘监测装置在直流系统中的应用[J]. 电力系统保护与控制, 2008, 36(15): 91-93. Chen Yuanping, Li Shujun, Zhang Yukui. Application of insulated monitoring device in DC system[J]. Power System Protection and Control, 2008, 36(15): 91-93.
[6]
黄海宏, 全成, 黄锦. 基于差流检测法的分布式直流接地巡检系统[J]. 电子测量与仪器学报, 2009, 23(11): 36-41. Huang Haihong, Quan Cheng, Huang Jin. Development of distributed DC grounding detecting system based on differential current detecting method[J]. Journal of Electronic Measurement and Instrument, 2009, 23(11): 36-41.
[7]
尹星光, 何铭宁, 徐玉凤, 等. 直流接地巡检装置误、漏选线问题分析[J]. 继电器, 2008, 36(10): 83-85. Yin Xingguang, He Mingning, Xu Yufeng, et al. Analysis on the wrongly or missed line selection with DC ground fault patrol device[J]. Relay, 2008, 36(10): 83-85.
[8]
王友仁, 崔江, 刘新峰. 直流系统在线绝缘检测技术研究[J]. 仪器仪表学报, 2005, 26(8): 849-852. Wang Youren, Cui Jiang, Liu Xinfeng. DC system insulation automatic monitoring instrument[J]. Chinese Journal of Scientific instrument, 2005, 26(8): 849-852.
[9]
王瑞祥, 刘峰, 熊小伏, 等. 变电站直流电源绝缘在线监测新方法[J]. 电力自动化设备, 2009, 29(12): 65-67. Wang Ruixiang, Liu Feng, Xiong Xiaofu, et al. On-line insulation monitoring of substation DC power supply[J]. Electric Power Automation Equipment, 2009, 29(12): 65-67.
[10]
James Lenz, Alan S Edelstein. Magnetic sensors and their applications[J]. IEEE Sensors Journal, 2006, 6(3): 631-649.
[11]
胡君, 尹华杰. 基于数字滤波器的直流系统接地故障检测法[J]. 继电器, 2006, 34(17): 13-17. Hu Jun, Yin Huajie. Fault grounding detecting of DC system based on digital filter[J]. Relay, 2006, 34(17): 13-17.
[12]
李志强, 钱进. 分布式绝缘监测系统同步测量方案[J]. 高电压技术, 2007, 33(5): 196-198. Li Zhiqiang, Qian Jin. Novel synchronous measurement for distributed insulation supervising system[J]. High Voltage Engineering, 2007, 33(5): 196-198.
[13]
张毅, 张泉, 李永丽. 直流系统接地检测[J]. 电力系统及其自动化学报, 2005, 2(1): 27-30. Zhang Yi, Zhang Quan, Li Yongli. Ground fault detection[J]. Proceedings of the CSU-EPSA, 2005, 2(1): 27-30.
[14]
苏义鑫, 刘林伟. 平衡电阻法监测直流系统绝缘[J]. 电力系统自动化, 2003, 27(14): 65-68. Su Yixin, Liu Linwei. Monitoring and detecting of DC system insulation by balance resistance method[J]. Automation of Electric Power Systems, 2003, 27(14): 65-68.
[15]
孙鸣, 马娟. 直流系统微机型绝缘监测装置电阻选择[J]. 电力系统保护与控制, 2011, 39(4): 128-131. Sun Ming, Ma Juan. The resistor selection of micro- computer-based insulation monitor for DC system[J]. Power System Protection and Control, 2011, 39(4): 128-131.
宋人杰, 王晓东, 苏畅. 直流接地故障监测装置的设计[J]. 高电压技术, 2010, 36(4): 975-979. Song Renjie, Wang Xiaodong, Su Chang. Design of apparatus for monitoring DC system ground faults[J]. High Voltage Engineering, 2010, 36(4): 975-979.
[18]
陈安伟, 乐全明, 于文斌, 等. 直流系统环路供电方式及环路接地问题研究[J]. 电力系统保护与控制, 2010, 38(11): 133-136. Chen Anwei, Yue Quanming, Yu Wenbin, et al. Research on DC loop power supply mode and the loop grounding[J]. Power System Protection and Control, 2010, 38(11): 133-136.
[19]
王尧, 李奎, 郭志涛, 等. 磁调制式直流漏电流互感器[J]. 电工电能新技术, 2012, 31(2): 69-73. Wang Yao, Li Kui, Guo Zhitao, et al. Magnetic modulation-based DC leakage current transformer[J]. Advanced Technology of Electrical Engineering and Enegy, 2012, 31(2): 69-73.
[20]
魏伟明, 魏秉国. 直流系统负极一点接地致开关跳闸原因分析[J]. 继电器, 2008, 36(9): 76-79. Wei Weiming, Wei Bingguo. Causes Analysis about one point earthing leading to breaker tripping in DC system[J]. Relay, 2008, 36(9): 76-79.
[21]
Cavallini A, Conti M, Montanari G C, et al. PD inference for the early detection of electrical treeing in insulation systems[J]. IEEE Transactions on Dielec- trics and Electrical Insulation, 2004, 11(4): 724-735.
[22]
Jose M. Understand ground fault detection & isolation in DC system[C]. IEEE Power Engineering Society Summer Meeting, Seattle, USA, 2000: 1707-1711.
[23]
Jishun J, Hua J. Study of insulation monitoring device for DC system based on multi-switch combination[C]. Second International Symposium on Computational Intelligence and Design(ISCID), Changsha, 2009: 429-433.