全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

基于时延的高精度泄漏点超声定向检测方法

, PP. 391-395

Full-Text   Cite this paper   Add to My Lib

Abstract:

针对当前气体泄漏点检测定向精度低的情况,提出一种基于时延的高精度超声检测方法.该方法利用3个呈等边三角形分布的超声传感器接收由泄漏点产生的超声波,根据3路信号的相对时延值确定泄漏点的方向.为克服采样间隔对时延估计精度的限制,采用基于三次样条插值的时延估计算法估计信号时延值,并对不同核窗长度下的各100组实验数据的时延值进行误差统计,得到其均方差并与其Cramér-Rao下界比较,发现二者的变化趋势具有良好的一致性.在此基础上研究了时延值均方差,超声传感器间距和泄漏点距离对定向精度的影响.结果表明定向误差随时延值均方差增大而增大,随超声传感器间距增大而减小,随泄漏点距离增大而增大;定向精度比单超声传感器检测方法提高7~10倍.

References

[1]  Goodman M, Zeno J R, Mabbs L.Ultrasonic leak detecting apparatus: United States, 5955670[P].1999-09-21
[2]  蔡茂林,香川利春.气动系统的能量消耗评价体系及能量损失分析[J].机械工程学报,2007,43(9):69-74 Cai Maolin, Kagawa T.Energy consumption assesment and energy loss analysis in pneumatic system [J].Chinese Journal of Mechanical Engineering, 2007, 43(9):69-74(in Chinese)
[3]  Izikoff M, Stumpf M, Samson H.System and method for leak detection: United States, 2010/0039271A1 [P].2010-3-18
[4]  Saidur R, Rahim N A, Hasanuzzaman M.A review on compressed-air energy use and energy savings [J].Renewable and Sustainable Energy Reviews, 2010,14(4):1135-1153
[5]  Edwards P A, Bruck F, Hennessy J.Sonic leak testing on ink delivery systems and ink jet heads: United States, 7770999B2 [P].2010-08-10
[6]  Edwards P A, Bruck F, Hennessy J.Sonic leak testing on ink delivery systems and ink jet heads: United States, 7770999B2 [P].2010-08-10
[7]  Cespedes I, Huang Y, Ophir J, et al.Methods for estimation of subsample time delays of digitized echo signals [J].Ultrasonic Imaging, 1995,17(2):142-171
[8]  Lai Xiaoming, Torp H.Interpolation methods for time-delay estimation using cross-correlation method for blood velocity measurement [J].IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1999, 46(2): 277-290
[9]  Crespo R J.Evaluation of energy usage in the chemical industry and effective measures to reduce energy losses [D].Starkville: Mississippi State University, 2009
[10]  Viola F, Walker W F.A spline-based algorithm for continuous time-delay estimation using sampled data [J].IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2005, 52(1): 80-93
[11]  Liao Pingping, Cai Maolin.Study on compressed air leak detection using ultrasonic detection technology and instrument [C]//Proceedings of 6th IEEE Conference on Industrial Electronics and Applications.Beijing, China: IEEE, 2011:1690-1693
[12]  Carter G C.Coherence and time delay estimation [J].Proceedings of the IEEE, 1987, 75(2):236-255
[13]  Goodman M, Zeno J R, Mabbs L.Ultrasonic leak detecting apparatus: United States, 5955670[P].1999-09-21
[14]  Crespo R J.Evaluation of energy usage in the chemical industry and effective measures to reduce energy losses [D].Starkville: Mississippi State University, 2009
[15]  Liao Pingping, Cai Maolin.Study on compressed air leak detection using ultrasonic detection technology and instrument [C]//Proceedings of 6th IEEE Conference on Industrial Electronics and Applications.Beijing, China: IEEE, 2011:1690-1693
[16]  冯若, 姚锦钟,关立勋, 等.超声手册[M].南京: 南京大学出版社, 1999: 254-260 Feng Ruo, Yao Jinzhong, Guan Lixun, et al.Ultrasonics handbook [M].Nanjing : Nanjing University Press, 1999: 254-260(in Chinese)
[17]  Izikoff M, Stumpf M, Samson H.System and method for leak detection: United States, 2010/0039271A1 [P].2010-3-18
[18]  植木孝.超音波式ガス漏洩検出器[J].センサ技術,1987,7(11):18-20
[19]  冯若, 姚锦钟,关立勋, 等.超声手册[M].南京: 南京大学出版社, 1999: 254-260 Feng Ruo, Yao Jinzhong, Guan Lixun, et al.Ultrasonics handbook [M].Nanjing : Nanjing University Press, 1999: 254-260(in Chinese)
[20]  Walker W F, Trahey G E.A fundamental limit on delay estimation using partially correlated speckle signals [J].IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control,1995, 42(2): 301-308
[21]  植木孝.超音波式ガス漏洩検出器[J].センサ技術,1987,7(11):18-20
[22]  Cespedes I, Huang Y, Ophir J, et al.Methods for estimation of subsample time delays of digitized echo signals [J].Ultrasonic Imaging, 1995,17(2):142-171
[23]  Viola F, Walker W F.A comparison of the performance of time-delay estimators in medical ultrasound [J].IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2003, 50(4): 392-401
[24]  Lai Xiaoming, Torp H.Interpolation methods for time-delay estimation using cross-correlation method for blood velocity measurement [J].IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1999, 46(2): 277-290
[25]  Viola F, Walker W F.A spline-based algorithm for continuous time-delay estimation using sampled data [J].IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2005, 52(1): 80-93
[26]  Carter G C.Coherence and time delay estimation [J].Proceedings of the IEEE, 1987, 75(2):236-255
[27]  Walker W F, Trahey G E.A fundamental limit on delay estimation using partially correlated speckle signals [J].IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control,1995, 42(2): 301-308
[28]  Viola F, Walker W F.A comparison of the performance of time-delay estimators in medical ultrasound [J].IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2003, 50(4): 392-401

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133