全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
化工学报  2012 

环形通道内置螺旋线圈过冷流动沸腾传热特性

DOI: 10.3969/j.issn.0438-1157.2012.10.012, PP. 3086-3093

Keywords: 螺旋线圈,环形通道,过冷沸腾,强化系数,经验关系式

Full-Text   Cite this paper   Add to My Lib

Abstract:

研究了置有螺旋线圈的内管加热环形通道中水的过冷流动沸腾传热特性。环形通道由铜制加热棒外套石英玻璃管构成,不同螺旋节距和线丝直径构成的5种螺旋线圈用于实验。对每种置入螺旋线圈管和光滑管分别进行了不同质量流速和热负荷下的16组实验,分析了线丝直径和线圈节距对传热系数的影响规律及机理。结果表明,螺旋线圈存在能使流体发生旋转分离,且使汽化核心密度增大,从而有效强化过冷沸腾换热;传热系数随着线圈节距的减小、线丝直径的增加,即节径比(P/e)减小而增大,当P/e最小为1.5时强化效果最好;最佳强化换热性能较光滑管的高出109%。将实验数据与4个经验关系式的预测值进行了比较,并给出了不同工况下各实验管的强化系数对比。

References

[1]  Dong Zhiguang(董智广),Yu Hongling(郁鸿凌),Dong Wei(董伟),Li Ruiyang(李瑞阳).Change of bubble behavior in electric field and its effects on boiling heat transfer[J].CIESC Journal (化工学报),2009,60(1):15-20
[2]  Zhou Qiangtai(周强泰),Huang Suyi(黄素逸).Heat Transfer Enhancement of Boiler and Heat Exchanger Heat Transfer(锅炉与热交换器传热强化)[M].Beijing:Hydraulic and Electric Power Press,1991:96-100
[3]  Tang Yufeng(唐玉峰),Tian Maocheng(田茂诚),Zhang Guanmin(张冠敏),Jiang Bo(姜波).Flow and heat transfer analysis of flat plate channel with spiral coil inserts[J].Proceedings of the CSEE(中国电机工程学报),2011,31(2):55-61
[4]  Tong Mingwei(童明伟),Zhang Hongji(张洪济).Flow boiling characteristic of F12 in the tubes with inserted helical coils[J].Journal of Chongqing University(重庆大学学报),1994,17(5):36-41
[5]  Yun R,Hwang J-S,Chung J T,Kim Y.Flow boiling heat transfer characteristics of nitrogen in plain and wire coil inserted tubes[J].International Journal of Heat and Mass Transfer,2007,50(11/12):2339-2345
[6]  Gungor K E,Winterton R H S.Simplified general correlation for saturated flow boiling and comparisons of correlations with data[J].Chemical Engineering Research&Design,1987,65(2):148-156 Engineering Research target="_blank">
[7]  Liu Z,Winterton R H S.A general correlation for saturated and subcooled flow boiling in tubes and annuli,based on a nucleate pool boiling equation[J].International Journal of Heat and Mass Transfer,1991,34(11):2759-2766
[8]  Shah M M.Generalized prediction of heat transfer during subcooled boiling in annuli[J].Heat Transfer Engineering,1983,4(1):24-31
[9]  Gungor K E,Winterton R H S.A general correlation for flow boiling in tubes and annuli[J].International Journal of Heat and Mass Transfer,1986,29(3):351-358
[10]  Cooper M G.Saturated nucleate pool boiling[C]//1st U.K.National Conference on Heat Transfer.UK:Industrial and Chemical Engineering Symposium Series,1984
[11]  Barbosa J R,Hewitt G F,Richardson S M.Forced convective boiling of steam-water in a vertical annulus at high qualities[J].Experimental Thermal and Fluid Science,2002,26(1):65-75
[12]  Prodanovic V,Fraser D,Salcudean M.Bubble behavior in subcooled flow boiling of water at low pressures and low flow rates[J].International Journal of Multiphase Flow,2002,28(1):1-19