化工学报  2015 

气液过滤过程中液滴二次夹带现象分析

DOI: 10.11949/j.issn.0438-1157.20141731, PP. 1344-1352

Keywords: 二次夹带,气溶胶,过滤,润湿性,过滤速度,天然气

Full-Text   Cite this paper   Add to My Lib

Abstract:

在天然气长距离输送过程中,天然气夹带的液滴严重影响压缩机组的安全可靠运行。利用所建立的滤芯过滤性能检测装置,以癸二酸二辛酯为实验介质,分析了天然气净化用滤芯气液过滤过程中液滴二次夹带现象的特征,比较了滤材润湿性和过滤速度等参数的影响。结果表明:当滤芯仅由聚结层组成时,滤芯过滤过程中存在液滴二次夹带现象,二次夹带将导致下游气体中液滴数量增多,且有较大液滴出现,稳态阶段滤芯累积效率在大粒径处下降;液滴在滤材表面的润湿性对二次夹带现象具有重要影响,可润湿型滤材表面更易出现液滴二次夹带现象,在相同过滤速度下,若需提高过滤效率,宜选用不可润湿型滤材制作工业滤芯;在0.1~0.3m·s-1过滤速度范围内,提高过滤速度可减少液滴二次夹带现象的发生,与不可润湿型滤芯相比,可润湿型滤芯过滤效果的改善更为明显;滤芯增加排液层可有效消除液滴二次夹带现象。

References

[1]  Rayor P C, Leith D. The influence of accumulated liquid on fibrous filter performance [J]. Journal of Aerosol Science, 2000, 31: 19-34
[2]  Mead-Hunter R, King A J C, Mullins B J. Aerosol-mist coalescing filters-a review [J].Separation and Purification Technology, 2014, 133: 484 -506
[3]  Xiong Zhiyi (熊至宜), Ji Zhongli (姬忠礼), Feng Liang (冯亮), et al. Measurement and analysis on influencing factors of filtration performance of filter coalescer element [J]. CIESC Journal (化工学报), 2012, 63 (6): 1742-1748
[4]  Calvert S, Jashnani I L, Yung S. Entrainment separators for scrubbers [J]. Air Pollut.Control Ass., 1974, 24 : 971
[5]  Nigmatulin R I, Nigmatulin B I, Khodzhaev Y D, et al. Entrainment and deposition rates in a dispersed-film flow [J]. International Journal of Multiphase Flow, 1996, 22 : 19-30
[6]  Azzopardi B J, Sanaullah K S. Re-entrainment in wave-plate mist eliminators [J]. Chemical Engineering Science, 2002, 57: 3557-3563
[7]  Zang Liye(臧丽叶), Tian Ruifeng(田瑞峰), Sun Lanxin(孙兰昕), et al. Breakdown of liquid films driven by horizontal gas flow in wave-plate channel [J]. CIESC Journal (化工学报), 2014, 65 (3): 862-869
[8]  Li Baisong(李柏松), Ji Zhongli(姬忠礼), Feng Liang(冯亮). Influence of liquid properties on gas-liquid separation performance of filter [J]. CIESC Journal (化工学报), 2010, 61 (5): 1150-1156
[9]  Mullins B J, Pfrang A, Braddock R D, Schimmel T, et al. Detachment of liquid droplets from fibres-experimental and theoretical evaluation of detachment force due to interfacial tension effects [J]. Journal of Colloid and Interface Science, 2007, 312 : 333-340
[10]  Argo W B, Chen G K C, Kocatas B M, et al. Fiber bed separator and method for separation of aerosols from gases without re-entrainment [P]: US, 4086070. 1978
[11]  GB/T 6165-2008 [S]. Beijing: Standards Press of China, 2008
[12]  EN 779: 2012 [S]. England : The British Standards Institution, 2012
[13]  ASHRAE 52.2 :2007 [S]. America: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., 2007
[14]  Charvet A, Gonthier Y, Gonze E, et al. Experimental and modelled efficiencies during the filtration of a liquid aerosol with a fibrous medium [J]. Chemical Engineering Science, 2010, 65 : 1875-1886
[15]  Contal P, Simao J, Thomas D, et al. Clogging of fiber filters by submicron droplets. Phenomena and influence of operating conditions [J].Journal of Aerosol Science, 2004, 35: 263-278
[16]  Bai Chengxin, Gosman A D. Development of methodology for spray impingement simulation //SAE International Congress and Exposition [C]. USA, 1995
[17]  Perry R H. Perry's Chemical Engineers' Handbook [M]. Beijing: Chemical Industry Press, 1993: 5-117

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133