化工学报  2012 

增压双效氨水吸收制冷循环性能分析

DOI: 10.3969/j.issn.0438-1157.2012.z2.032, PP. 170-175

Keywords: 氨水吸收,制冷,增压,双效,性能系数

Full-Text   Cite this paper   Add to My Lib

Abstract:

在双效氨水吸收制冷循环的基础上,提出了一种增压双效氨水吸收制冷循环。结合Schulz氨水状态方程式,通过数学建模对该循环过程进行模拟计算。分析了增压比、制冷温度、热源温度、冷却水温度对循环性能的影响,并和双效氨水吸收制冷循环进行比较。结果表明,增压双效氨水吸收制冷循环中,增压比是非常重要的影响因素,它直接影响循环的性能系数;在其他工况参数不变的条件下,增压双效氨水吸收制冷循环有其最佳的增压比;在适当的增压比下,扩大了双效循环的应用范围,在制冷温度较低时,也可以具有较高的性能系数,而且在相同制冷温度下,降低驱动热源温度也能达到理想的循环效果,从而使本循环可利用的热源范围得以扩展。

References

[1]  Costiuc L,Costiuc I.Solar powered resorption cooling system[J].Bulletin of the Transilvania University of Brasov,2010,3(52):7-14
[2]  Wang Yanjue(王延觉),Ou Ruhao(欧汝浩),Chen Huanxin(陈焕新),Zhang Chun’an(张春安).Boosting double effect absorption refrigeration circle using heat and mass transfer separation absorber [J].Fluid Machinery(流体机械),2007,35(5):75-78
[3]  Kumar A R,Udayakumar M.Simulation studies on GAX absorption compression cooler[J].Energy Conversion and Management,2007,48:2064-2610
[4]  Du Kai(杜垲),Liao Jianmin(廖健敏).Performance analysis of ammonia-water absorption refrigeration GAX cycle[J].Journal of Southeast University(东南大学学报),2005,35(5):766-768
[5]  Rameshkumar A,Udayakumar M,Saravanan R.Heat transfer studies on a GAXAC(generator-absorber-exchange absorption compressior) cooler[J].Applied Energy,2009,86:2056-2064
[6]  Goswami D Y.Solar thermal power technology:present status and ideas for the future[J].Energy Sources,1998,20(2):137-145
[7]  Demirkaya G,Padilla R V,Goswami D Y,Stefanakos E M,Rahm M.Analysis of a combined power and cooling cycle for low-grade heat sources[J].International Journal of Energy Research,2011,35:1145-1157
[8]  Xu Shiming(徐士鸣).Calculation and analysis of a double-effect cascade absorption refrigeration cycle in middle pressure [J].Journal of Dalian University of Technology(大连理工大学学报),2000,40(3):309-312
[9]  Zhang Baohuai(张宝怀),Chen Yaping(陈亚平),Shi Mingheng(施明恒).Performance of double-effect NH3-H2O absorption cycle [J].Journal of Chemical Industry and Engineering (China) (化工学报),2007,58(4):829-833
[10]  Zhao Zongchang(赵宗昌),Zhang Xiaodong(张晓冬). Thermal performance analysis of ammonia absorption/compression refrigeration cycle driven by low temperature waste heat [J].Chemical Industry and Engineering Progress(化工进展),2009,28(S1):459-462
[11]  Schultz S C G.Equations of state for the system ammonia-water for use with computers[J].Progress in Refrigera-tion Science and Technology,1973,12:431-436
[12]  Li Zhengyu(李征宇),Zhao Jianhua(赵健华),Zhao Zongchang(赵宗昌).Research on ammonia-water absorption refrigeration system with an ejector [J].Energy Conservation Technology(节能技术),2010,28(3):241-245
[13]  Venegas M,Lzquierdo M,Vega M,et al.Thermodynamic study of multistage absorption cycles using low-temperature heat[J].International Journal of Energy Research,2002,26(8):775-791
[14]  Sozen A,Kurt M,Akcyol M A,et al.Performance prediction of a solar driven ejector-absorption cycle using fuzzy logic[J].Renewable Energy,2004,29(1):53-71