Radial Basis Function Neural Network Application to Power System Restoration Studies

DOI: 10.1155/2012/654895

Full-Text   Cite this paper   Add to My Lib

Abstract:

One of the most important issues in power system restoration is overvoltages caused by transformer switching. These overvoltages might damage some equipment and delay power system restoration. This paper presents a radial basis function neural network (RBFNN) to study transformer switching overvoltages. To achieve good generalization capability for developed RBFNN, equivalent parameters of the network are added to RBFNN inputs. The developed RBFNN is trained with the worst-case scenario of switching angle and remanent flux and tested for typical cases. The simulated results for a partial of 39-bus New England test system show that the proposed technique can estimate the peak values and duration of switching overvoltages with good accuracy. 1. Introduction In recent years, due to economic competition and deregulation, power systems are being operated closer and closer to their limits. At the same time, power systems have increased in size and complexity. Both factors increase the risk of major power outages. After a blackout, power needs to be restored as quickly and reliably as possible and, consequently, detailed restoration plans are necessary [1, 2]. If the frequency characteristic of the system shows resonance conditions around multiples of the fundamental frequency, very high and weakly damped temporary overvoltages (TOVs) of long duration may occur when the system is excited by a harmonic disturbance, such as the switching of lightly loaded transformers or transformer saturation [1, 3–5]. Overvoltages can be classified as transient overvoltages, sustained overvoltages, harmonic resonance overvoltages, and overvoltages resulting from Ferroresonance. Excessive sustained overvoltages may lead to damage of transformers and other power system equipment. Transient overvoltages are a consequence of switching operations on long transmission lines, or the switching of capacitive devices, and may result in arrester failures. Ferroresonance is a nonharmonic resonance characterized by overvoltages whose waveforms are highly distorted and can cause catastrophic equipment damages [1]. Overvoltage will put the transformer into saturation, causing core heating and copious harmonic current generation. Circuit breaker called upon to operate during periods of high voltage will have reduced interrupting capability. At some voltage even the ability to interrupt line-charging current will be lost [1, 6–8]. In [9], overvoltages caused by transformer energization have been evaluated using radial basis function neural network (RBFNN). Also in [10], switching overvoltages

References

[1]  M. M. Adibi, “Overvoltage control during restoration,” IEEE Transactions on Power Systems, vol. 7, no. 4, pp. 1464–1470, 1992.
[2]  A. Ketabi, A. M. Ranjbar, and R. Feuillet, “Analysis and control of temporary overvoltages for automated restoration planning,” IEEE Transactions on Power Delivery, vol. 17, no. 4, pp. 1121–1127, 2002.
[3]  M. M. Adibi, J. N. Borkoski, and R. J. Kafka, “Analytical tool requirements for power system restoration,” IEEE Transactions on Power Systems, vol. 9, no. 3, pp. 1582–1591, 1994.
[4]  T. Hayashi, D. P. Roberts, K. Walve et al., “Modelling and simulation of Black Start and restoration of an electric power system. Results of a questionnaire,” Electra, no. 131, pp. 155–169, 1990.
[5]  I. Sadeghkhani, A. Ketabi, and R. Feuillet, “New approach to harmonic overvoltages reduction during transformer energization via controlled switching,” in Proceedings of the 15th International Conference on Intelligent System Applications to Power Systems (ISAP '09), Curitiba, Brazil, November 2009.
[6]  I. Sadeghkhani, A. Ketabi, and R. Feuillet, “Estimation of temporary overvoltages during power system restoration using artificial neural network,” in Proceedings of the 15th International Conference on Intelligent System Applications to Power Systems (ISAP '09), Curitiba, Brazil, November 2009.
[7]  S. A. Taher and I. Sadeghkhani, “Estimation of magnitude and time duration of temporary overvoltages using ANN in transmission lines during power system restoration,” Simulation Modelling Practice and Theory, vol. 18, no. 6, pp. 787–805, 2010.
[8]  I. Sadeghkhani, Using artificial neural network for estimation of switching and resonance overvoltages during bulk power system restoration [M.S. thesis], Department of Electrical Engineering, University of Kashan, 2009.
[9]  I. Sadeghkhani, A. Yazdekhasti, A. Mortazavian, and N. Haratian, “Radial basis function neural network based approach to estimate transformer harmonic overvoltages,” Advances in Computer Science and its Applications, vol. 1, no. 1, pp. 38–44, 2012.
[10]  D. Thukaram, H. P. Khincha, and S. Khandelwal, “Estimation of switching transient peak overvoltages during transmission line energization using artificial neural network,” Electric Power Systems Research, vol. 76, no. 4, pp. 259–269, 2006.
[11]  A. Ketabi and I. Sadeghkhani, Electric Power Systems Simulation Using MATLAB, Morsal Publications, 2011.
[12]  G. Sybille, P. Brunelle, L. Hoang, L. A. Dessaint, and K. Al-Haddad, “Theory and applications of power system blockset, a MATLAB/Simulink-based simulation tool for power systems,” in Proceedings of the IEEE Power Engineering Society Winter Meeting, vol. 1, pp. 774–779, 2000.
[13]  M. M. Duró, “Damping modelling in transformer energization studies for system restoration: some standard models compared to field measurements,” in Proceedings of the IEEE Bucharest PowerTech, Bucharest, Romania, June 2009.
[14]  P. G. Boliaris, J. M. Prousalidis, N. D. Hatziargyriou, and B. C. Papadias, “Simulation of long transmission lines energization for black start studies,” in Proceedings of the 7th Mediterranean Electrotechnical Conference (MELECON '94), pp. 1093–1096, April 1994.
[15]  G. Sybille, M. M. Gavrilovic, J. Belanger, and V. Q. Do, “Transformer saturation effects on EHV system overvoltages,” IEEE Transactions on Power Apparatus and Systems, vol. 104, no. 3, pp. 671–680, 1985.
[16]  G. Morin, “Service restoration following a major failure on the hydroquebec power system,” IEEE Transactions on Power Delivery, vol. 2, no. 2, pp. 454–463, 1987.
[17]  M. Joorabian, S. M. A. T. Asl, and R. K. Aggarwal, “Accurate fault locator for EHV transmission lines based on radial basis function neural networks,” Electric Power Systems Research, vol. 71, no. 3, pp. 195–202, 2004.
[18]  P. K. Dash, A. K. Pradhan, and G. Panda, “Application of minimal radial basis function neural network to distance protection,” IEEE Transactions on Power Delivery, vol. 16, no. 1, pp. 68–74, 2001.
[19]  S. Haykin, Neural Network: A Comprehensive Foundation, Prentice Hall, 2nd edition, 1998.
[20]  S. Wunderlich, M. M. Adibi, R. Fischl, and C. O. D. Nwankpa, “Approach to standing phase angle reduction,” IEEE Transactions on Power Systems, vol. 9, no. 1, pp. 470–478, 1994.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133