The aim of this study is to present some practical state-of-the-art considerations in acquiring satisfactory signals for electroencephalographic signal acquisition. These considerations are important for users and system designers. Especially choosing correct electrode and design strategy of the initial electronic circuitry front end plays an important role in improving the system's measurement performance. Considering the pitfalls in the design of biopotential measurement system and recording session conditions creates better accuracy. In electroencephalogram (EEG) recording electrodes, system electronics including filtering, amplifying, signal conversion, data storing, and environmental conditions affect the recording performance. In this paper, EEG electrode principles and main points of electronic noise reduction methods in EEG signal acquisition front end are discussed, and some suggestions for improving signal acquisition are presented. 1. Introduction Although basics of the electroencephalogram (EEG) measurement in man have been the same since 1929, it was first made by Hans Berger, the technological developments give the opportunity to build much more sophisticated acquisition systems regarding clinical needs and scientific researches. The human brain generates electrical signals called EEG signals which are related to body functions, and this paper is about their acquiring. These signals are roughly less than 100? V and 100?Hz and can be measured with electrodes placed on the scalp, noninvasively. Because of their low amplitude due to the skull’s composition, the measurement of EEG is more difficult than the other noninvasive biosignal measurements such as the electrocardiogram, electromyogram, electrooculogram, and so forth. Having expensive bio-signal recording systems cannot guarantee acquiring proper signals. In that sense, some factors to acquire good EEG signals should be considered in new designs and during recording sessions. These major considerations are discussed and some suggestions are presented in this paper. In bio-signal recordings, electrodes are the initial elements which are used for converting biopotential signals due to biopotential sources into electrical signals. Figure 1 shows the simplified biopotential measurement. EEG electrodes are usually made of metal and are produced as cup-shaped, disc, needle, or microelectrode to measure intra-cortex potentials. Silver chloride (AgCl) is preferred for common neurophysiologic applications [1]. Because Ag is a slightly soluble salt, AgCl quickly saturates and comes to
References
[1]
C. M. Sinclair, M. C. Gasper, and A. S. Blum, “Basic electronics in clinical neurophysiology,” in The Clinical Neurophysiology Primer, A. S. Blum and S. B. Rutkove, Eds., pp. 3–18, Humana Press, Totowa, NJ, USA, 2007.
[2]
D. Prutchi and M. Norris, Design and Develeopment of Medical Electronic Instrumentation, John Wiley & Sons, Hoboken, NJ, USA, 2005.
[3]
M. Leach Jr., “Fundamentals of low-noise analog circuit design,” Proceedings of the IEEE, vol. 82, no. 10, pp. 1515–1538, 1994.
[4]
H. W. Ott, Noise Reduction Techniques in Electronic Systems, John Wiley & Sons, New York, NY, USA, 2nd edition, 1988.
[5]
H. H. Jasper, “The ten–twenty electrode system of the international federation,” Electroencephalography and Clinical Neurophysiology, vol. 10, pp. 367–380, 1958.
[6]
R. Oostenveld and P. Praamstra, “The five percent electrode system for high-resolution EEG and ERP measurements,” Clinical Neurophysiology, vol. 112, no. 4, pp. 713–719, 2001.
O. J. Prohaska, F. Olcaytug, P. Pfundner, and H. Dragaun, “Thin-film multiple electrode probes: possibilities and limitations,” IEEE Transactions on Biomedical Engineering, vol. 33, no. 2, pp. 223–229, 1986.
[11]
B. A. Taheri, R. T. Knight, and R. L. Smith, “A dry electrode for EEG recording,” Electroencephalography and Clinical Neurophysiology, vol. 90, no. 5, pp. 376–383, 1994.
[12]
W. J. R. Dunseath and E. F. Kelly, “Multichannel PC-based data-acquisition system for high-resolution EEG,” IEEE Transactions on Biomedical Engineering, vol. 42, no. 12, pp. 1212–1217, 1995.
[13]
A. C. MettingVanRijn, A. P. Kuiper, T. E. Dankers, and C. A. Grimbergen, “Low-cost active electrode improves the resolution in biopotential recordings,” in Proceedings of the 18th Annual International Conference of the IEEE Engineering in Medicine and Biology, pp. 101–102, Amsterdam, The Netherlands, October-November 1996.
[14]
G. Litscher, “A multifunctional helmet for noninvasive neuromonitoring,” Journal of Neurosurgical Anesthesiology, vol. 10, no. 2, pp. 116–119, 1998.
[15]
G. Gargiulo, P. Bifulco, R. A. Calvo, M. Cesarelli, C. Jin, and A. van Schaik, “A mobile EEG system with dry electrodes,” in Proceedings of IEEE-BIOCAS Biomedical Circuits and Systems Conference (BIOCAS '08), pp. 273–276, Baltimore, Md, USA, November 2008.
[16]
P. J. Rousche and R. A. Normann, “Chronic recording capability of the Utah intracortical electrode array in cat sensory cortex,” Journal of Neuroscience Methods, vol. 82, no. 1, pp. 1–15, 1998.
[17]
B. B. Winter and J. G. Webster, “Reduction of interference due to common mode voltage in biopotential amplifiers,” IEEE Transactions on Biomedical Engineering, vol. 30, no. 1, pp. 58–62, 1983.
[18]
R. Aston, Principles of Biomedical Instrumentation and Measurement, Prentice Hall, Columbus, Ohio, USA, 1990.
[19]
J. G. Webster, Medical Instrumentation, Application and Design, Houghton Mifflin, Boston, Mass, USA, 2nd edition, 1992.
[20]
G. Litscher, “A multifunctional helmet for noninvasive neuromonitoring,” Journal of Neurosurgical Anesthesiology, vol. 10, no. 2, pp. 116–119, 1998.
[21]
I. Ulbert, E. Halgren, G. Heit, and G. Karmos, “Multiple microelectrode-recording system for human intracortical applications,” Journal of Neuroscience Methods, vol. 106, no. 1, pp. 69–79, 2001.
[22]
A. B. Usakli and N. G. Gencer, “Performance tests of a novel electroencephalographic data-acquisition system,” in Proceedings of the 5th IASTED International Conference on Biomedical Engineering (BioMED '07), pp. 253–257, Innsbruck, Austria, February 2007.
[23]
A. B. Usakli and N. G. Gencer, “USB-based 256-channel electroencephalographic data acquisition system for electrical source imaging of the human brain,” Instrumentation Science & Technology, vol. 35, no. 3, pp. 255–273, 2007.
[24]
A. B. Usakli and S. Gurkan, “Design of a novel efficient human-computer interface: an electrooculagram based virtual keyboard,” Accepted in IEEE Transactions on Instrumentation and Measurement.