全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

Application Concept of Zero Method Measurement in Microwave Radiometers

DOI: 10.4236/mi.2015.43003, PP. 19-31

Keywords: Microwave Radiometer, Null Method of Measurement, Fluctuation Sensitivity

Full-Text   Cite this paper   Add to My Lib

Abstract:

This article examined in detail microwave radiometer functioning algorithm with synchronously using of the two types of pulse modulation: amplitude pulse modulation and pulse-width modulation. This allows a zero-radiometer measurement method to realize when the fluctuation effect of the receiver gain and the influence of its own noise changes are minimized. A zero balance automatically maintains in radiometer. The antenna signal is indirectly determined through the signal duration that controls the pulse-width modulation. An analytical expression of the fluctuation sensitivity was obtained in a general form. From its analysis gain in sensitivity, conditions were defined by the optimizing of the radiometer input knot’s construction. Three modifications of the radiometer input knot were researched. Fluctuation sensitivity at different measurement range was determined for modification of the radiometer input knot.

References

[1]  Sharkov, E.A. (2003) Passive Microwave Remote Sensing of the Earth: Physical Foundations. Springer/PRAXIS, Berlin.
[2]  Astafieva, N.M., Raev, M.D. and Sharkov, E.A. (2006) Portret Zemli iz kosmosa. Globalnoe radioteplovoe pole. Priroda, 9, 75-86.
[3]  Dicke, R.H. (1946) The Measurement of Thermal Radiation at Microwave Frequencies. Review of Scientific Instruments, 17, 268-275.
http://dx.doi.org/10.1063/1.1770483
[4]  Orhaur, T. and Waltman, W. (1962) Switched Load Radiometer. Public National Radio Astronomy Observatory, 1, 179-204.
[5]  Ryle, M. and Vonberg, D.D. (1948) An Investigation of Radio-Frequency Radiation from the Sun. Proceeding of the Royal Society, 193, 98-119.
http://dx.doi.org/10.1098/rspa.1948.0036
[6]  Troitskiy, V.S., Lubina, A.G. and Zolotov, A.V. (1951) Sravnenie teplovih shumov nekotorix materialov nulevim metodom. Dokladi Akademii Nauk SSSR, 4, 583-586.
[7]  Hardy, W.N., Gray, K.W. and Love, A.W. (1974) An S-Band Radiometer Design with High Absolute Precision. IEEE Transactions on Microwave Theory and Techniques, MTT-22, 382-391.
[8]  Lawrence, R.F., Harrington, R.F. and Higdon, N.S. (1982) Flight Test Evaluation of a Noise Injection Dicke Microwave Radiometer Employing Digital Signal Processing. IEEE MTT-S International Microwave Symposium Digest, New York, 15-17 June 1982, 90-92.
[9]  de Maagt, P.J.I., Oerlemans, R.A.E., van Gestel, J.C.A.M. and Herben, M.H.B.J. (1992) A Novel Radiometer Receiver Stabilization Method. International Journal of Infrared and Millimeter Waves, 13, 1075-1097.
http://dx.doi.org/10.1007/BF01009052
[10]  Brown, S.T., Desai, S., Wenwen, Lu. and Tanner, A.B. (2007) On the Long-Term Stability of Microwave Radiometers Using Noise Diodes for Calibration. IEEE Transactions on Geoscience and Remote Sensing, 45, 1908-1920.
[11]  Vlaby, F.T., Moore, R.K. and Fung, A.K. (1981) Microwave Remote Sensing. Artech House, Norwood.
[12]  Sironi, G., Inzani, P., Limon, M. and Marchioni, C. (1990) Evaluation of Small Signals with a Differential Radiometer (with Application to Radio Observations at 2.5 Ghz). Measurement Science and Technology, 1, 1119-1121.
http://dx.doi.org/10.1088/0957-0233/1/10/025
[13]  Esepkina, N.A., Korolkov, D.V. and Pariyskiy, U.N. (1973) Radioteleskopi i radiometri. Nauka, Moscow, 415 p.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133