全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
Sensors  2014 

The MAIN Shirt: A Textile-Integrated Magnetic Induction Sensor Array

DOI: 10.3390/s140101039

Keywords: textile integration, magnetic induction, cardiorespiratory monitoring, mobile devices

Full-Text   Cite this paper   Add to My Lib

Abstract:

A system is presented for long-term monitoring of respiration and pulse. It comprises four non-contact sensors based on magnetic eddy current induction that are textile-integrated into a shirt. The sensors are technically characterized by laboratory experiments that investigate the sensitivity and measuring depth, as well as the mutual interaction between adjacent pairs of sensors. The ability of the device to monitor respiration and pulse is demonstrated by measurements in healthy volunteers. The proposed system (called the MAIN (magnetic induction) Shirt) does not need electrodes or any other skin contact. It is wearable, unobtrusive and can easily be integrated into an individual’s daily routine. Therefore, the system appears to be a suitable option for long-term monitoring in a domestic environment or any other unsupervised telemonitoring scenario.

References

[1]  Meystre, S. The current state of telemonitoring: A comment on the literature. Telemed. e-Health 2005, 11, 63–69.
[2]  Teichmann, D.; Foussier, J.; Buscher, M.; Walter, M.; Leonhardt, S. Textile Integration of a Magnetic Induction Sensor for Monitoring of Cardiorespiratory Activity. Proceedings of World Congress on Medical Physics and Biomedical Engineering, Beijing, China, 26–31 May 2012; pp. 1350–1353.
[3]  Teichmann, D.; Kuhn, A.; Leonhardt, S.; Walter, M. Human motion classification based on a textile integrated and wearable sensor array. Physiol. Meas. 2013, 34, 963–975.
[4]  Tarjan, P.P.; McFee, R. Electrodeless measurements of the effective resistivity of the human torso and head by magnetic induction. IEEE Trans. Biomed. Eng. 1968, 15, 266–278.
[5]  Griffiths, H. Magnetic induction tomography. Meas. Sci. Technol. 2001, 12, 1126–1131.
[6]  Scharfetter, H.; Lackner, H.K.; Rosell, J. Magnetic induction tomography: Hardware for multi-frequency measurements in biological tissues. Physiol. Meas. 2001, 22, 131–146.
[7]  Riedel, C.H.; Keppelen, M.; Nani, S.; Merges, R.D.; D?ssel, O. Planar system for magnetic induction conductivity measurement using a sensor matrix. Physiol. Meas. 2004, 25, 403–411.
[8]  Cordes, A.; Foussier, J.; Pollig, D.; Leonhardt, S. A portable magnetic induction measurement system (PIMS). Biomed. Tech. Biomed. Eng. 2012, 57, 131–138.
[9]  Vas, R. Electronic device for physiological kinetic measurements and detection of extraneous bodies. IEEE Trans. Biomed. Eng. 1967, BME-14, 2–6.
[10]  Kwok, M.C.; Pepper, M.G. Noninvasive detection of ventricular wall motion by electromagnetic coupling: Part 1 Theory. Med. Biol. Eng. Comput. 1991, 29, 136–140.
[11]  Guardo, R.; Trudelle, S.; Adler, A.; Boulay, C.; Savard, P. Contactless Recording of Cardiac Related Thoracic Conductivity Changes. Proceedings of IEEE 17th Annual Conference Engineering in Medicine and Biology Society, Montreal, QC, Canada, 23–25 September 1995; pp. 1581–1582.
[12]  Humal, L.H.; Vedru, J. Physiological measurement based on foucault principle: Set-up of the problem. Med. Biol. Eng. Comput. 1996, 34, 183–184.
[13]  Steffen, M.; Aleksandrowicz, A.; Leonhardt, S. Mobile noncontact monitoring of heart and lung activity. IEEE Trans. Biomed. Circuit. Syst. 2007, 1, 250–257.
[14]  Richer, A.; Adler, A. Eddy Current Based Flexible Sensor for Contactless Measurement of Breathing. Proceedings of the IEEE Instrumentation and Measurement Technology Conference, Ottawa, Ont, Canada, 16–9 May 2005; pp. 257–260.
[15]  Teichmann, D.; Foussier, J.; Jia, J.; Leonhardt, S.; Walter, M. Noncontact monitoring of cardiorespiratory activity by electromagnetic coupling. IEEE Trans. Biomed. Eng. 2013, 60, 2142–2152.
[16]  Scharfetter, H.; Merwa, R.; Pilz, K. A new type of gradiometer for the receiving circuit of magnetic induction tomography (MIT). Physiol. Meas. 2005, 26, S307–S318.
[17]  Libby, H.L. Introduction to Electromagnetic Nondestructive Test Methods; R. E. Krieger Pub. Co.: Huntington, NY, USA, 1971.
[18]  Vedru, J.; Gordon, R. Model of an inductive sensor of cardiac activity attached to patient. J. Phys. Conf. Ser. , 224.
[19]  Gabriel, C.; Gabriel, S.; Corthout, E. The dielectric properties of biological tissues: I. Literature survey. Phys. Med. Biol. 1996, 41, 2231–2249.
[20]  Gabriel, S.; Lau, R.W.; Gabriel, C. The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. Phys. Med. Biol. 1996, 41, 2251–2269.
[21]  Gabriel, S.; Lau, R.W.; Gabriel, C. The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. Phys. Med. Biol. 1996, 41, 2271–2293.
[22]  Houck, H.; Gaw, N.W. A New Method of Accurate Frequency Measurement. Proceedings of the Radio Club of America, New York, USA, December 1960.
[23]  Altman, D.G.; Bland, J.M. Measurement in medicine: The analysis of method comparison studies. The Statistician 1983, 32, 307.
[24]  Rioul, O.; Vetterli, M. Wavelets and signal processing. IEEE Signal Process. Mag. 1991, 8, 14–38.
[25]  ANSI/AAMI EC13:2002 Cardiac Monitors, Heart Rate Meters, and Alarms; Association for the Advancement of Medical Instrumentation: Arlington, MA, USA, 2002.
[26]  Ulbrich, M.; Marleaux, B.; Mühlsteff, J.; Schoth, F.; Koos, R.; Teichmann, D.; Leonhardt, S. High spatial and temporal resolution 4D FEM simulation of the thoracic bioimpedance using MRI scans. J. Phys. Conf. Ser. 2013, 434, 012074.
[27]  Hart, L.; Ko, H.; Meyer, J.; Vasholz, D.; Joseph, R. A noninvasive electromagnetic conductivity sensor for biomedical applications. IEEE Trans. Biomed. Eng. 1988, 35, 1011–1022.
[28]  Groote, A.D.; Wantier, M.; Cheron, G.; Estenne, M.; Paiva, M. Chest wall motion during tidal breathing. J. Appl. Physiol. 1997, 83, 1531–1537.
[29]  Kim, S.; Brendle, C.; Lee, H.Y.; Walter, M.; Gloeggler, S.; Krueger, S.; Leonhardt, S. Evaluation of a 433 MHz band body sensor network for biomedical applications. Sensors 2013, 13, 898–917.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133