Thermocouples are the most frequently used sensors for temperature measurement because of their wide applicability, long-term stability and high reliability. However, one of the major utilization problems is the linearization of the transfer relation between temperature and output voltage of thermocouples. The linear calibration equation and its modules could be improved by using regression analysis to help solve this problem. In this study, two types of thermocouple and five temperature ranges were selected to evaluate the fitting agreement of different-order polynomial equations. Two quantitative criteria, the average of the absolute error values | e| ave and the standard deviation of calibration equation e std, were used to evaluate the accuracy and precision of these calibrations equations. The optimal order of polynomial equations differed with the temperature range. The accuracy and precision of the calibration equation could be improved significantly with an adequate higher degree polynomial equation. The technique could be applied with hardware modules to serve as an intelligent sensor for temperature measurement.
References
[1]
Nicholas, J.V.; White, D.R. Traceable Temperatures; John Wiley & Sons, Inc.: New York, NY, USA, 1994.
[2]
Childs, P.R.N.; Greenwood, J.R.; Long, C.A. Review of temperature measurement. Rev. Sci. Instrum. 2000, 71, 2959–2978.
[3]
Kerlin, T.W.; Joshson, M. Practical Thermocouple Thermometry, 2nd ed. ed.; ISA Publisher: New York, NY, USA, 2012.
[4]
Yilmaz, N.; Gill, W.; Donaldson, A.B.; Lucero, R.E. Problems encountered in fluctuating flame temperature measurements by thermocouple. Sensors 2008, 8, 7882–7893.
[5]
National Institute of Standards and Testing. Available online: http://srdata.nist.gov/its90/main/ (accessed on 5 December 2013).
[6]
Sarma, U.; Boruah, P.K. Design and development of a high precision thermocouple based smart industrial thermometer with on line linearisation and data logging feature. Measurement 2010, 43, 1589–1594.
[7]
Ayman, A.A.; Ei-Lail, A.S.A. A novel circuit for thermocouple signals linearization using AD converter. IJITCS 2013, 3, 56–60.
[8]
Ndlovu, P.; Preater, J. Calibration using a piecewise simple linear regression model. Commun. Stat. Theory Method. 2001, 20, 229–242.
[9]
Rivera-Mejia, J.; Carrillo-Romero, M.; Herrera-Ruiz, G. Self-compensation to build reconfigurable measurement systems. IEEE Instrum. Meas. Mag. 2013, 16, 10–19.
Ghosh, D.; Patranabis, D. Linearizing of transducers through a generalized software technique. J. Phys. E Meas. Sci. Technol. 1991, 2, 102–105.
[12]
Mondal, N.; Abudhahir, A.; Jana, S.K.; Munshi, S.; Bhattacharya, D.P. A log amplifier based linearization scheme for thermocouples. Sens. Transd. 2009, 100, 1–10.
[13]
Sarma, U.; Chakraborty, D.; Boruah, P.K. Design of a smart and high precision industrial temperature measurement and monitoring system using K-type thermocouple and SPI-compatible temperature sensor. Sens. Transd. 2009, 102, 1–9.
[14]
Danisman, K.; Dalkiran, I.; Celebi, F.V. Design of a high precision temperature measurement system based on artificial neural network for different thermocouple types. Measurement 2006, 39, 696–700.
[15]
Myers, R.H. Classical and Modern Regression with Application, 2nd ed. ed.; PWS and Kent Publisher: Boston, MA, USA, 1986.
[16]
Chen, C. Evaluation of resistance-temperature calibration equations for NTC thermistors. Measurement 2009, 42, 1103–1111.
[17]
Mallick, P.; Nayak, C.; Behera, T.B. Least Square Based Parabolic Regression to Determine Calibration Constant in Measurement. Proceedings of the 5th International Conference on Industrial and Information Systems, Mangalore, India, 29 July–1 August 2010; pp. 334–338.