Purpose. To investigate age- and position-related changes of anterior chamber angle anatomy in normal, healthy eyes. Patients and Methods. Thirty subjects were separated into a younger and older cohort. The superior and inferior anterior chamber angles of the eyes were measured in supine and sitting positions by ultrasound biomicroscopy (UBM) with bag/balloon technology. Statistical analysis was used to evaluate positional and age-related changes in angle morphology. Results. In the younger cohort, no location or positional differences in angle anatomy were observed. In the older cohort, the inferior quadrant was significantly narrower than the superior quadrant ( ) in the supine position. This cohort also demonstrated an interaction effect between position and location. In the older cohort, the angle was deeper inferiorly while the subject was sitting but was deeper superiorly while the subject was supine. Conclusion. Comparison of positional variations in anterior chamber angle anatomy as measured by UBM has recently become possible. This study found that age-related positional changes in the anterior chamber angle anatomy exist in normal healthy eyes. 1. Introduction Ultrasound biomicroscopy (UBM) provides noninvasive high-resolution in vivo imaging of the anterior segment. While anterior tissues are readily visualized by conventional methods (e.g., slit-lamp biomicroscopy and gonioscopy), structures posterior to the iris are hidden due to absorption of light by the iris pigment epithelium. Such structures may also be undetected by anterior segment optical coherence tomography (ASOCT), given the inability of light to penetrate the iris pigment epithelium. B-scan ultrasonography, though extremely useful in imaging posterior ocular structures, is also not ideal for ciliary body imaging due to the near-field artifact and poorer resolution obtained with lower frequencies. However, the higher frequency ultrasound waves, utilized by UBM, are not obstructed by pigmented tissue and give the required resolution. Thus, UBM can be used to image not only the anterior chamber angle but also the ciliary body, peripheral lens, zonules, and the posterior chamber of the eye [1]. UBM has been demonstrated to be useful in evaluating the anterior segment of eyes with the primary angle closure spectrum of disorders [2]. It also may be used to elucidate the mechanism of malignant glaucoma, pigmentary glaucoma, and anterior scleral disease [3–5]. Therefore, UBM has become the current standard for imaging abnormalities of ciliary body position, as are found in plateau iris
References
[1]
H. Ishikawa and J. S. Schuman, “Anterior segment imaging: ultrasound biomicroscopy,” Ophthalmology Clinics of North America, vol. 17, no. 1, pp. 7–20, 2004.
[2]
R. Sihota, T. Dada, R. Gupta, P. Lakshminarayan, and R. M. Pandey, “Ultrasound biomicroscopy in the subtypes of primary angle closure glaucoma,” Journal of Glaucoma, vol. 14, no. 5, pp. 387–391, 2005.
[3]
C. J. Pavlin, M. Easterbrook, J. J. Hurwitz, K. Harasiewicz, P. Eng, and F. S. Foster, “Ultrasound biomicroscopy in the assessment of anterior scleral disease,” American Journal of Ophthalmology, vol. 116, no. 5, pp. 628–635, 1993.
[4]
C. J. Pavlin, P. Macken, G. Trope, F. Feldman, K. Harasiewicz, and F. S. Foster, “Ultrasound biomicroscopic features of pigmentary glaucoma,” Canadian Journal of Ophthalmology, vol. 29, no. 4, pp. 187–192, 1994.
[5]
G. E. Trope, C. J. Pavlin, A. Bau, C. R. Baumal, and F. S. Foster, “Malignant glaucoma: clinical and ultrasound biomicroscopic features,” Ophthalmology, vol. 101, no. 6, pp. 1030–1035, 1994.
[6]
N. P. Bell, R. M. Feldman, Y. Zou, and T. C. Prager, “New technology for examining the anterior segment by ultrasonic biomicroscopy,” Journal of Cataract and Refractive Surgery, vol. 34, no. 1, pp. 121–125, 2008.
[7]
K. Esaki, H. Ishikawa, J. M. Liebmann, and R. Ritch, “A technique for performing ultrasound biomicroscopy in the sitting and prone positions,” Ophthalmic Surgery and Lasers, vol. 31, no. 2, pp. 166–169, 2000.
[8]
K. Esaki, K. Ito, K. Matsunaga, K. Sugimoto, M. Sasoh, and Y. Uji, “Anterior chamber structural change in postural variation in pseudoexfoliation syndrome,” Journal of Japanese Ophthalmological Society, vol. 105, no. 8, pp. 524–529, 2001.
[9]
R. Sano, T. Kurokawa, Y. Kurimoto, D. Miyazawa, and N. Yoshimura, “Comparison between the anterior chamber configuration in the supine position and that in the prone position in patients with narrow angle,” Nippon Ganka Gakkai Zasshi, vol. 105, no. 6, pp. 388–393, 2001.
[10]
H. V. Tran, H. Ishikawa, J. M. Liebmann, and R. Ritch, “A new silicone eyecup for ultrasound biomicroscopy,” Ophthalmic Surgery and Lasers, vol. 34, no. 1, pp. 73–75, 2003.
[11]
D. S. Friedman, G. Gazzard, C. B. Min et al., “Age and sex variation in angle findings among normal Chinese subjects: a comparison of UBM, Scheimpflug, and gonioscopic assessment of the anterior chamber angle,” Journal of Glaucoma, vol. 17, no. 1, pp. 5–10, 2008.
[12]
K. Esaki, H. Ishikawa, J. M. Liebmann, D. S. Greenfield, Y. Uji, and R. Ritch, “Angle recess area decreases with age in normal Japanese,” Japanese Journal of Ophthalmology, vol. 44, no. 1, pp. 46–51, 2000.
[13]
Z. Pan, T. Furuya, and K. Kashiwagi, “Longitudinal changes in anterior chamber configuration in eyes with open-angle glaucoma and associated factors,” Journal of Glaucoma, vol. 21, no. 5, pp. 296–301, 2012.
[14]
L. Xu, W. F. Cao, Y. X. Wang, C. X. Chen, and J. B. Jonas, “Anterior chamber depth and chamber angle and their associations with ocular and general parameters: the Beijing Eye Study,” American Journal of Ophthalmology, vol. 145, no. 5, pp. 929–936, 2008.
[15]
Y. Chen, Y. Z. Bao, and X. T. Pei, “Morphologic changes in the anterior chamber in patients with cortical or nuclear age-related cataract,” Journal of Cataract and Refractive Surgery, vol. 37, no. 1, pp. 77–82, 2011.
[16]
H. Ishikawa, K. Esaki, J. M. Liebmann, Y. Uji, and R. Ritch, “Ultrasound biomicroscopy dark room provocative testing: a quantitative method for estimating anterior chamber angle width,” Japanese Journal of Ophthalmology, vol. 43, no. 6, pp. 526–534, 1999.
[17]
H. Ishikawa, K. Inazumi, J. M. Liebmann, and R. Ritch, “Inadvertent corneal indentation can cause artifactitious widening of the iridocorneal angle on ultrasound biomicroscopy,” Ophthalmic Surgery and Lasers, vol. 31, no. 4, pp. 342–345, 2000.