An automatic vessel diameter measurement technique based on linear discriminant analysis (LDA) has been proposed. After estimating the vessel wall, the vessel cross-section profile is divided into three regions: two corresponding to the background and one to the vessel. The algorithm was tested on more than 5000 cross-sections of retinal vessels from the REVIEW dataset through comparative study with the state-of-the-art techniques. Cross-correlation analyses were performed to determine the degree to which the proposed technique was close to the ground truth. The results indicate that proposed algorithm consistently performed better than most of other techniques and was highly correlated with the manual measurement as the reference diameter. The proposed method does not require any supervision and is suitable for automatic analysis. 1. Introduction Retina images allow noninvasive viewing of the in-vivo vessels and have been established as indicator for incidence of diabetic retinopathy [1, 2], early indicator of stroke [3, 4] and hypertension [5]. It is the best modality to see the microvascular abnormalities [6] such as change in the width of the vasculature. Changes in the width of the retinal arteriole and venules are known as direct indictors of retinal vasculature abnormality [7]; detection of which requires accurate measurement of retinal vessel diameter. However, complex background and uneven lighting conditions result in poor contrast at vessel edges [8], and this result in inaccurate diameter measurement. Several techniques have been published previously for vessel diameter estimation and edge delineation. Brinchmann-Hansen and Heier proposed the Half Height Full Width (HHFW) method in which the diameter was defined as the distance between the points on the vessel intensity cross-section profile where the function reaches 50% of its maximum value to either side of the estimated centre point [9]. Gregson et al. [10] fitted a rectangle to the vessel profile and estimated the width by setting the area under the curve equal to the area under the rectangle. In [11], the vessel profile was approximated by 1D Gaussian function based on the assumption that the intensity profile follows a symmetric Gaussian-like shape. This was further extended to 2D Gaussian by Lowell et al. [12] which was more robust compared to 1D Gaussian method. Gao et al. [13] established that the retinal vessel profile could be fitted with twin-Gaussian model. The study found a linear relationship between the standard deviation (SD) of the Gaussian and the gold standard diameters
References
[1]
T. T. Nguyen, J. J. Wang, F. M. A. Islam et al., “Retinal arteriolar narrowing predicts incidence of diabetes,” Diabetes, vol. 57, no. 3, pp. 536–539, 2008.
[2]
T. Y. Wong, R. Klein, A. Richey Sharrett et al., “Retinal arteriolar narrowing and risk of diabetes mellitus in middle-aged persons,” Journal of the American Medical Association, vol. 287, no. 19, pp. 2528–2533, 2002.
[3]
R. Kawasaki, M. Z. Che Azemin, D. K. Kumar et al., “Fractal dimension of the retinal vasculature and risk of stroke: a nested case-control study,” Neurology, vol. 76, no. 20, pp. 1766–1767, 2011.
[4]
X. Benavent, L. Martínez-Costa, G. Ayala, J. Domingo, and P. Marco, “Semi-automated evaluation tool for retinal vasculopathy,” Computer Methods and Programs in Biomedicine, vol. 95, no. 3, pp. 288–299, 2009.
[5]
Y. Gao and Q. P. Wei, “Hypertension related ophthalmocace,” International Journal of Ophthalmology, vol. 8, no. 7, pp. 1454–1457, 2008.
[6]
M. L. Baker, P. J. Hand, J. J. Wang, and T. Y. Wong, “Retinal signs and stroke: revisiting the link between the eye and brain,” Stroke, vol. 39, no. 4, pp. 1371–1379, 2008.
[7]
J. J. Wang, P. Mitchell, H. Leung, E. Rochtchina, T. Y. Wong, and R. Klein, “Hypertensive retinal vessel wall signs in a general older population: the Blue Mountains Eye Study,” Hypertension, vol. 42, no. 4, pp. 534–541, 2003.
[8]
X. Xu, M. Niemeijer, Q. Song et al., “Vessel boundary delineation on fundus images using graph-based approach,” IEEE Transactions on Medical Imaging, vol. 30, no. 6, pp. 1184–1191, 2011.
[9]
O. Brinchmann-Hansen and H. Heier, “Theoretical relations between light streak characteristics and optical properties of retinal vessels,” Acta Ophthalmologica, vol. 64, no. 179, pp. 33–37, 1986.
[10]
P. H. Gregson, Z. Shen, R. C. Scott, and V. Kozousek, “Automated grading of venous beading,” Computers and Biomedical Research, vol. 28, no. 4, pp. 291–304, 1995.
[11]
L. Zhou, M. S. Rzeszotarski, L. J. Singerman, and J. M. Chokreff, “Detection and quantification of retinopathy using digital angiograms,” IEEE Transactions on Medical Imaging, vol. 13, no. 4, pp. 619–626, 1994.
[12]
J. Lowell, A. Hunter, D. Steel, A. Basu, R. Ryder, and R. L. Kennedy, “Measurement of retinal vessel widths from fundus images based on 2-D modeling,” IEEE Transactions on Medical Imaging, vol. 23, no. 10, pp. 1196–1204, 2004.
[13]
X. W. Gao, A. Bharath, A. Stanton, A. Hughes, N. Chapman, and S. Thom, “Quantification and characterisation of arteries in retinal images,” Computer Methods and Programs in Biomedicine, vol. 63, no. 2, pp. 133–146, 2000.
[14]
N. Chapman, N. Witt, X. Gao et al., “Computer algorithms for the automated measurement of retinal arteriolar diameters,” British Journal of Ophthalmology, vol. 85, no. 1, pp. 74–79, 2001.
[15]
B. Al-Diri, A. Hunter, and D. Steel, “An active contour model for segmenting and measuring retinal vessels.,” IEEE Transactions on Medical Imaging, vol. 28, no. 9, pp. 1488–1497, 2009.
[16]
G. A. F. Seber, “Discriminant analysis,” in Multivariate Observations, pp. 279–346, John Wiley & Sons, New York, NY, USA, 1984.
[17]
B. Al-Diri, A. Hunter, D. Steel, M. Habib, T. Hudaib, and S. Berry, “REVIEW-a reference data set for retinal vessel profiles,” in Proceedings of the 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBS '08), pp. 2262–2265, August 2008.
[18]
I. G. P. S. Wijaya, K. Uchimura, and G. Koutaki, “Human face security system using alternative linear discriminant analysis based classifier,” in Proceedings of the 17th Korea-Japan Joint Workshop on Frontiers of Computer Vision (FCV '11), pp. 1–6, 2011.
[19]
B. Aliahmad, D. K. Kumar, S. Janghorban, M. Z. Azemin, H. Hao, and R. Kawasaki, “Automatic retinal vessel profiling using multi-step regression method,” in Proceedings of the Annual International Conference of the IEEE on Engineering in Medicine and Biology Society (EMBC '11), pp. 2606–2609, August 2011.
[20]
X. Zhao, W. Duan, T. Lin, and B. Li, “A method of retinal vessel width measurement,” in Proceedings of the 2nd International Conference on Computer and Automation Engineering (ICCAE '10), pp. 443–446, February 2010.
[21]
B. Aliahmad, D. K. Kumar, S. Janghorban, M. Z. C. Azemin, H. Hao, and R. Kawasaki, “Retinal vessel diameter measurement using multi-step regression method,” in Proceedings of the Biosignals and Biorobotics Conference (BRC '12) ISSNIP, pp. 1–4, 2012.
[22]
L. Gang, O. Chutatape, and S. M. Krishnan, “Detection and measurement of retinal vessels in fundus images using amplitude modified second-order Gaussian filter,” IEEE Transactions on Biomedical Engineering, vol. 49, no. 2, pp. 168–172, 2002.
[23]
H. Li, W. Hsu, M. L. Lee, and H. Wang, “A piecewise Gaussian model for profiling and differentiating retinal vessels,” in Proceedings of the International Conference on Image Processing (ICIP '03), vol. 1, pp. 1069–1072, September 2003.