Purpose. The purpose of this finite element study was to compare stresses, strains, and displacements of double versus single implant, in immediate loading for replacing mandibular molar. Materials and Methods. Two 3D FEM models were made to simulate implant designs. The first model used 6?mm wide-diameter implant to support a single molar crown. The second model used 3.75-3.75 double implant design. Each model was analyzed with a single force magnitude of 70?N in oblique axis in three locations. Results. This FEM study suggested that micromotion can be well controlled by both double implants and 6?mm single wide-diameter implant. The Von Mises stress for double implant had 31%–43% stress reduction compared to the 6?mm implant. Conclusion. Within the limitations of the paper, when the mesiodistal space for artificial tooth is more than 12.5?mm, under immediate loading, the double implant support should be considered. 1. Introduction Threaded root form osseointegrated implants were designed originally to support complete arched fixed implant supported restorations for completely edentulous patients [1]. Now, this type of implant is used to support single-implant supported crowns and fixed partial dentures in partially edentulous areas [2]. Many in vitro and animal studies attempted to predict the biomechanical and clinical behavior of dental material and technique associated with implant-supported prosthesis [3–5]. In vitro methods include conventional in vitro model analyses [6], photo elastic analyses [4, 7, 8], and finite element analyses [9]. In vitro studies are less complicated and less expensive than clinical trials and produce results relatively quickly compared to randomized controlled trials [10]. FEM analysis has been used to provide analytical solutions to problems involving complex geometric forms [9]. Posterior teeth have two or three roots, having from 450 to 533?mm2 as a total anchorage area in good quality bone [11], whereas surface area of 3.75?mm implant varies from 72 to 256?mm2 depending on its length. The molar has a crown surface area of approximately 100?mm2, whereas 3.75?mm implant has cross section area 10.9?mm2. Therefore, the tooth can dissipate occlusal forces efficiently, whereas masticatory forces are exerted at angle mesiodistally and buccolingually creating bending and torquing vectors [12] on the implant. The cross-sectional area for 2 (3.75?mm) implants is 21.9?mm2, whereas for single (5?mm) implant 19.6?mm2 and for 2 (4?mm) implant 19.6?mm2 [13]. Greater dimension of bone buccolingually is required for placement of
References
[1]
G. A. Zarb and A. Schmitt, “The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto study. Part I: surgical results,” The Journal of Prosthetic Dentistry, vol. 63, no. 4, pp. 451–457, 1990.
[2]
R. Haas, N. Mensdorff-Pouilly, G. Mailath, and G. Watzek, “Br{right parenthesis, less than}nemark single tooth implants: a preliminary report of 76 implants,” The Journal of Prosthetic Dentistry, vol. 73, no. 3, pp. 274–279, 1995.
[3]
C. Aparicio and P. Orozco, “Use of 5-mm-diameter implants: periotest values related to a clinical and radiographic evaluation,” Clinical Oral Implants Research, vol. 9, no. 6, pp. 398–406, 1998.
[4]
W. J. Seong, T. W. P. Korioth, and J. S. Hodges, “Experimentally induced abutment strains in three types of single-molar implant restorations,” Journal of Prosthetic Dentistry, vol. 84, no. 3, pp. 318–326, 2000.
[5]
T. J. Balshi, R. E. Hernandez, M. C. Pryszlak, and B. Rangert, “A comparative study of one implant versus two replacing a single molar,” International Journal of Oral and Maxillofacial Implants, vol. 11, no. 3, pp. 372–378, 1996.
[6]
C. M. Jeong, A. A. Caputo, R. S. Wylie, S. C. Son, and Y. C. Jeon, “Bicortically stabilized implant load transfer,” International Journal of Oral and Maxillofacial Implants, vol. 18, no. 1, pp. 59–65, 2003.
[7]
P. P. Binon, “Evaluation of the effectiveness of a technique to prevent screw loosening,” Journal of Prosthetic Dentistry, vol. 79, no. 4, pp. 430–432, 1998.
[8]
K. B. Tan and J. I. Nicholls, “Implant-abutment screw joint preload of 7 hex-top abutment systems,” International Journal of Oral and Maxillofacial Implants, vol. 16, no. 3, pp. 367–377, 2001.
[9]
J. P. Geng, K. B. C. Tan, and G. R. Liu, “Application of finite element analysis in implant dentistry: a review of the literature,” Journal of Prosthetic Dentistry, vol. 85, no. 6, pp. 585–598, 2001.
[10]
A. Geramy and S. M. Morgano, “Finite element analysis of three designs of an implant-supported molar crown,” Journal of Prosthetic Dentistry, vol. 92, no. 5, pp. 434–440, 2004.
[11]
D. C. Freeman, Root surface area related to anchorage in the begg technique, Ph.D. thesis, University of Tennessee, Memphis, Tenn, USA, 1965.
[12]
B. Rangert, P. H. Krogh, B. Langer, and N. Van Roekel, “Bending overload and implant fracture: a retrospective clinical analysis,” The International Journal of Oral & Maxillofacial Implants, vol. 10, no. 3, pp. 326–334, 1995.
[13]
O. Bahat and M. Handelsman, “Use of wide implants and double implants in the posterior jaw: a clinical report,” International Journal of Oral and Maxillofacial Implants, vol. 11, no. 3, pp. 379–386, 1996.
[14]
B. Langer, L. Langer, I. Herrmann, and L. Jorneus, “The wide fixture: a solution for special bone situations and a rescue for the compromised implant. Part 1,” The International Journal of Oral & Maxillofacial Implants, vol. 8, no. 4, pp. 400–408, 1993.
[15]
S. L. Graves, C. E. Jansen, A. A. Siddiqui, and K. D. Beaty, “Wide diameter implants: indications, considerations and preliminary results over a two-year period,” Australian Prosthodontic Journal, vol. 8, pp. 31–37, 1994.
[16]
F. Renouard and F. Riachi, “Apport des implants de 5?mm de diametre en implantologie orale,” Implantologie, vol. 24, pp. 2069–2076, 1994.
[17]
J. Robinson, Understanding Finite Element Stress Analysis, Winbornde Robinson and Associates, Dorset, UK, 1981.
[18]
O. C. Zienkiewicz and R. Taylor, “Basic formulations and linear methods,” in The Finite Element Method, O. C. Zienkiewicz and R. Taylor, Eds., McGraw-Hill, London, UK, 4th edition, 1988.
[19]
L. Pierrisnard, G. Hure, M. Barquins, and D. Chappard, “Two dental implants designed for immediate loading: a finite element analysis,” International Journal of Oral and Maxillofacial Implants, vol. 17, no. 3, pp. 353–362, 2002.
[20]
M. M. Ash and S. J. Nelson, Wheeler’s Dental Anatomy, Physiology, and Occlusion, Elsevier, St. Louis, Mo, USA, 8th edition, 2003.
[21]
H. L. Huang, C. H. Chang, J. T. Hsu, A. M. Fallgatter, and C. C. Ko, “Comparison of implant body designs and threaded designs of dental implants: a 3-dimensional finite element analysis,” International Journal of Oral and Maxillofacial Implants, vol. 22, no. 4, pp. 551–562, 2007.
[22]
W. J. O’Brien, Dental Materials and Their Selection, Quintessence, Chicago, Ill, USA, 2nd edition, 2002.
[23]
H. S. Yang, L. A. Lang, A. Molina, and D. A. Felton, “The effects of dowel design and load direction on dowel-and-core restorations,” Journal of Prosthetic Dentistry, vol. 85, no. 6, pp. 558–567, 2001.
[24]
M. R. Rieger, K. Fareed, W. K. Adams, and R. A. Tanquist, “Bone stress distribution for three endosseous implants,” The Journal of Prosthetic Dentistry, vol. 61, no. 2, pp. 223–228, 1989.
[25]
C. J. Ivanoff, L. Sennerby, C. Johansson, B. Rangert, and U. Lekholm, “Influence of implant diameters on the integration of screw implants: an experimental study in rabbits,” International Journal of Oral and Maxillofacial Surgery, vol. 26, no. 2, pp. 141–148, 1997.
[26]
S. E. Eckert, S. J. Meraw, A. L. Weaver, and C. M. Lohse, “Early experience with wide-platform Mk II implants. Part I: implant survival. Part II: evaluation of risk factors involving implant survival,” International Journal of Oral and Maxillofacial Implants, vol. 16, no. 2, pp. 208–216, 2001.
[27]
G. Polizzi, B. Rangert, U. Lekholm, F. Gualini, and H. Lindstr?m, “Br?nemark System Wide Platform implants for single molar replacement: clinical evaluation of prospective and retrospective materials,” Clinical Implant Dentistry and Related Research, vol. 2, no. 2, pp. 61–69, 2000.
[28]
N. J. Attard and G. A. Zarb, “Implant prosthodontic management of partially edentulous patients missing posterior teeth: the Toronto experience,” Journal of Prosthetic Dentistry, vol. 89, no. 4, pp. 352–359, 2003.
[29]
E. P. Holmgren, R. J. Seckinger, L. M. Kilgren, and F. Mante, “Evaluating parameters of osseointegrated dental implants using finite element analysis–a two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction,” The Journal of Oral Implantology, vol. 24, no. 2, pp. 80–88, 1998.
[30]
A. P. Saadoun, D. Y. Sullivan, M. Krischek, and M. Le Gall, “Single tooth implant—management for success,” Practical Periodontics and Aesthetic Dentistry, vol. 6, no. 3, pp. 73–82, 1994.
[31]
X. Ding, S. H. Liao, X. H. Zhu, X. H. Zhang, and L. Zhang, “Effect of diameter and length on stress distribution of the alveolar crest around immediate loading implants,” Clinical Implant Dentistry and Related Research, vol. 11, no. 4, pp. 279–287, 2009.
[32]
C. S. Petrie and J. L. Williams, “Comparative evaluation of implant designs: influence of diameter, length, and taper on strains in the alveolar crest—a three-dimensional finite-element analysis,” Clinical Oral Implants Research, vol. 16, no. 4, pp. 486–494, 2005.
[33]
W. J. O’Brien, Dental Materials and Their Selection, Quintessence, Chicago, Ill, USA, 2nd edition, 1997.
[34]
K. R. Williams, C. J. Watson, W. M. Murphy, J. Scott, M. Gregory, and D. Sinobad, “Finite element analysis of fixed prostheses attached to osseointegrated implants,” Quintessence International, vol. 21, no. 7, pp. 563–570, 1990.
[35]
R. M. Cibirka, M. E. Razzoog, B. R. Lang, and C. S. Stohler, “Determining the force absorption quotient for restorative materials used in implant occlusal surfaces,” The Journal of Prosthetic Dentistry, vol. 67, no. 3, pp. 361–364, 1992.
[36]
T. Albrektsson, P. I. Br?nemark, H. A. Hansson, and J. Lindstrom, “Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man,” Acta Orthopaedica Scandinavica, vol. 52, no. 2, pp. 155–170, 1981.
[37]
R. M. Pilliar, J. M. Lee, and C. Maniatopoulos, “Observations on the effect of movement on bone ingrowth into porous-surfaced implants,” Clinical Orthopaedics and Related Research, vol. 208, pp. 108–113, 1986.