The Challenge of Delivering Therapeutic Aerosols to Asthma Patients

DOI: 10.1155/2013/102418

Full-Text   Cite this paper   Add to My Lib

Abstract:

The number of people with asthma continues to grow around the world, and asthma remains a poorly controlled disease despite the availability of management guidelines and highly effective medication. Patient noncompliance with therapy is a major reason for poor asthma control. Patients fail to comply with their asthma regimen for a wide variety of reasons, but incorrect use of inhaler devices is amongst the most common. The pressurised metered-dose inhaler (pMDI) is still the most frequently used device worldwide, but many patients fail to use it correctly, even after repeated tuition. Breath-actuated inhalers are easier to use than pMDIs. The rationale behind inhaler choice should be evidence based rather than empirical. When choosing an inhaler device, it is essential that it is easy to use correctly, dosing is consistent, adequate drug is deposited in both central and peripheral airways, and that drug deposition is independent of airflow. Regular checking of inhalation technique is crucial, as correct inhalation is one of the cornerstones of successful asthma management. 1. Introduction The incidence of asthma continues to rise worldwide, doubling over the last 10 years [1–4] and, consequently, asthma places a huge economic burden on healthcare resources [5]. Asthma management guidelines [1, 2] are now available in virtually every country; their aim is to achieve control of the disease with the lowest possible dose of medication prescribed [1, 2]. To this end, asthma guidelines advocate a stepwise pharmacological approach that consists in increasing (“step up”) the numbers of medications as asthma worsens, and decreasing (“step down”) medications when asthma is under control [1, 2]. Once control of asthma has been achieved and maintained for at least three months, a gradual reduction of the maintenance therapy is recommended to identify the minimum therapy required to maintain control [1, 2]. Unfortunately, the current level of asthma control falls far short of the goals for long-term asthma management [2, 6, 7], with many patients reporting day- and night-time symptoms at least once a week, and continuing to require unscheduled visits and hospitalisations [2, 6, 7]. One of the reason why asthma remains poorly controlled is that patients are deriving incomplete benefit from their inhaled medication, primarily because they are unable to use their inhalers correctly [8–11]. The benefits of inhaled therapy for the treatment of obstructive airway diseases, such as asthma, have been recognised for many years. In comparison with oral or parenteral

References

[1]  “Global Initiative for Asthma. Global strategy for asthma management and prevention,” Updated December 2012, http://www.asthmacure.com/.
[2]  British Thoracic Society Scottish Intercollegiate Guidelines Network, “British Guideline on the Management of Asthma,” Thorax, vol. 63, supplement 4, pp. 1–121, 2008.
[3]  K. F. Rabe, P. A. Vermeire, J. B. Soriano, and W. C. Maier, “Clinical management of asthma in 1999: the Asthma Insights and Reality in Europe (AIRE) study,” European Respiratory Journal, vol. 16, no. 5, pp. 802–807, 2000.
[4]  K. Gruffydd-Jones, “Measuring pulmonary function in practice,” Practitioner, vol. 246, no. 1635, pp. 445–448, 2002.
[5]  P. J. Barnes, B. Jonsson, and J. B. Klim, “The costs of asthma,” European Respiratory Journal, vol. 9, no. 4, pp. 636–642, 1996.
[6]  H. Chen, M. K. Gould, P. D. Blanc et al., “Asthma control, severity, and quality of life: quantifying the effect of uncontrolled disease,” Journal of Allergy and Clinical Immunology, vol. 120, no. 2, pp. 396–402, 2007.
[7]  P. M. O'Byrne, S. Pedersen, M. Schatz, et al., “The poorly explored impact of uncontrolled asthma,” Chest, vol. 143, no. 2, pp. 511–523, 2013.
[8]  G. K. Crompton, P. J. Barnes, M. Broeders et al., “The need to improve inhalation technique in Europe: a report from the Aerosol Drug Management Improvement Team,” Respiratory Medicine, vol. 100, no. 9, pp. 1479–1494, 2006.
[9]  D. Price, S. Bosnic-Anticevich, A. Briggs, et al., “Inhaler competence in asthma: common errors, barriers to use and recommended solutions,” Respiratory Medicine, vol. 107, no. 1, pp. 37–46, 2013.
[10]  A. Papi, J. Haughney, J. C. Virchow, N. Roche, S. Palkonen, and D. Price, “Inhaler devices for asthma: a call for action in a neglected field,” European Respiratory Journal, vol. 37, no. 5, pp. 982–985, 2011.
[11]  J. B. Fink and B. K. Rubin, “Problems with inhaler use: a call for improved clinician and patient education,” Respiratory Care, vol. 50, no. 10, pp. 1360–1374, 2005.
[12]  B. L. Laube, H. M. Janssens, F. H. C. De Jongh et al., “What the pulmonary specialist should know about the new inhalation therapies,” European Respiratory Journal, vol. 37, no. 6, pp. 1308–1331, 2011.
[13]  M. B. Dolovich, R. C. Ahrens, D. R. Hess et al., “Device selection and outcomes of aerosol therapy: evidence-based guidelines: American College of Chest Physicians/American College of Asthma, Allergy, and Immunology,” Chest, vol. 127, no. 1, pp. 335–371, 2005.
[14]  J. Sanchis, C. Corrigan, M. L. Levy, and J. L. Viejo, “Inhaler devices—from theory to practice,” Respiratory Medicine, vol. 107, no. 4, pp. 495–502, 2013.
[15]  M. B. Dolovich and R. Dhand, “Aerosol drug delivery: developments in device design and clinical use,” The Lancet, vol. 377, no. 9770, pp. 1032–1045, 2011.
[16]  D. R. Hess, “Aerosol delivery devices in the treatment of asthma,” Respiratory Care, vol. 53, no. 6, pp. 699–723, 2008.
[17]  J. Lenney, J. A. Innes, and G. K. Crompton, “Inappropriate inhaler use: assessment of use and patient preference of seven inhalation devices,” Respiratory Medicine, vol. 94, no. 5, pp. 496–500, 2000.
[18]  F. Lavorini, C. J. Corrigan, P. J. Barnes et al., “Retail sales of inhalation devices in European countries: so much for a global policy,” Respiratory Medicine, vol. 105, no. 7, pp. 1099–1103, 2011.
[19]  L. Hendeles, G. L. Colice, and R. J. Meyer, “Withdrawal of albuterol inhalers containing chlorofluorocarbon propellants,” The New England Journal of Medicine, vol. 356, no. 13, pp. 1344–1351, 2007.
[20]  D. L. Ross and B. J. Gabrio, “Advances in metered dose inhaler technology with the development of a chlorofluorocarbon-free drug delivery system,” Journal of Aerosol Medicine, vol. 12, no. 3, pp. 151–160, 1999.
[21]  D. Ganderton, D. Lewis, R. Davies, B. Meakin, G. Brambilla, and T. Church, “Modulite: a means of designing the aerosols generated by pressurized metered dose inhalers,” Respiratory Medicine, vol. 96, no. 4, pp. S3–S8, 2002.
[22]  C. L. Leach, “The CFC to HFA transition and its impact on pulmonary drug development,” Respiratory Care, vol. 50, no. 9, pp. 1201–1206, 2005.
[23]  B. J. Gabrio, S. W. Stein, and D. J. Velasquez, “A new method to evaluate plume characteristics of hydrofluoroalkane and chlorofluorocarbon metered dose inhalers,” International Journal of Pharmaceutics, vol. 186, no. 1, pp. 3–12, 1999.
[24]  D. Acerbi, G. Brambilla, and I. Kottakis, “Advances in asthma and COPD management: delivering CFC-free inhaled therapy using Modulite technology,” Pulmonary Pharmacology and Therapeutics, vol. 20, no. 3, pp. 290–303, 2007.
[25]  S. Dhillon and G. M. Keating, “Beclometasone dipropionate/formoterol: in an HFA-propelled pressurised metered-dose inhaler,” Drugs, vol. 66, no. 11, pp. 1475–1483, 2006.
[26]  S. P. Newman, D. Pavia, and S. W. Clarke, “How should a pressurized β-adrenergic bronchodilator be inhaled?” European Journal of Respiratory Diseases, vol. 62, no. 1, pp. 3–20, 1981.
[27]  G. K. Crompton, “How to achieve good compliance with inhaled asthma therapy,” Respiratory Medicine, vol. 98, no. 2, pp. S35–S40, 2004.
[28]  G. K. Crompton, “The adult patient's difficulties with inhalers,” Lung, vol. 168, pp. 658–662, 1990.
[29]  V. Giraud and N. Roche, “Misuse of corticosteroid metered-dose inhaler is associated with decreased asthma stability,” European Respiratory Journal, vol. 19, no. 2, pp. 246–251, 2002.
[30]  R. K. Schultz, “Drug delivery characteristics of metered-dose inhalers,” Journal of Allergy and Clinical Immunology, vol. 96, no. 2, pp. 284–287, 1995.
[31]  F. Lavorini and G. A. Fontana, “Targeting drugs to the airways: the role of spacer devices,” Expert Opinion on Drug Delivery, vol. 6, no. 1, pp. 91–102, 2009.
[32]  S. P. Newman and M. T. Newhouse, “Effect of add-on devices for aerosol drug delivery: deposition studies and clinical aspects,” Journal of Aerosol Medicine, vol. 9, no. 1, pp. 55–70, 1996.
[33]  P. W. Barry and C. O'Callaghan, “Inhalational drug delivery from seven different spacer devices,” Thorax, vol. 51, no. 8, pp. 835–840, 1996.
[34]  P. W. Barry and C. O'Callaghan, “The optimum size and shape of spacer devices for inhalational therapy,” Journal of Aerosol Medicine, vol. 8, no. 3, pp. 303–305, 1995.
[35]  S. P. Newman, “Spacer devices for metered dose inhalers,” Clinical Pharmacokinetics, vol. 43, no. 6, pp. 349–360, 2004.
[36]  J. P. Mitchell and M. W. Nagel, “Valved holding chambers (VHCs) for use with pressurised metered-dose inhalers (pMDIs): a review of causes of inconsistent medication delivery,” Primary Care Respiratory Journal, vol. 16, no. 4, pp. 207–214, 2007.
[37]  H. J. Zar, M. J. Asmus, and E. G. Weinberg, “A 500-ml plastic bottle: an effective spacer for children with asthma,” Pediatric Allergy and Immunology, vol. 13, no. 3, pp. 217–222, 2002.
[38]  S. A. Taylor, M. J. Asmus, J. Liang, I. Coowanitwong, R. Vafadari, and G. Hochhaus, “Performance of a corticosteroid inhaler with a spacer fashioned from a plastic cold-drink bottle: effects of changing bottle volume,” Journal of Asthma, vol. 40, no. 3, pp. 237–242, 2003.
[39]  M. Duarte and P. Camargos, “Efficacy and safety of a home-made non-valved spacer for bronchodilator therapy in acute asthma,” Acta Paediatrica, International Journal of Paediatrics, vol. 91, no. 9, pp. 909–913, 2002.
[40]  G. A. Fontana, F. Lavorini, M. Chiostri, W. Castellani, V. Boddi, and M. Pistolesi, “Large and small airway responses to procaterol hydrochloride administered through different extension devices in asthmatic patients,” Journal of Aerosol Medicine, vol. 12, no. 3, pp. 177–185, 1999.
[41]  F. Lavorini, P. Geri, M. Luperini et al., “Clinical and functional responses to salbutamol inhaled via different devices in asthmatic patients with induced bronchoconstriction,” British Journal of Clinical Pharmacology, vol. 58, no. 5, pp. 512–520, 2004.
[42]  F. Lavorini, P. Geri, L. Mariani et al., “Speed of onset of bronchodilator response to salbutamol inhaled via different devices in asthmatics: a bioassay based on functional antagonism,” British Journal of Clinical Pharmacology, vol. 62, no. 4, pp. 403–411, 2006.
[43]  F. Lavorini, P. Geri, G. Camiciottoli, M. Pistolesi, and G. A. Fontana, “Agreement between two methods for assessing bioequivalence of inhaled salbutamol,” Pulmonary Pharmacology and Therapeutics, vol. 21, no. 2, pp. 380–384, 2008.
[44]  J. H. Wildhaber, S. G. Devadason, E. Eber et al., “Effect of electrostatic charge, flow, delay and multiple actuations on the in vitro delivery of salbutamol from different small volume spacers for infants,” Thorax, vol. 51, no. 10, pp. 985–988, 1996.
[45]  C. O'Callaghan, J. Lynch, M. Cant, and C. Robertson, “Improvement in sodium cromoglycate delivery from a spacer device by use of an antistatic lining, immediate inhalation, and avoiding multiple actuations of drug,” Thorax, vol. 48, no. 6, pp. 603–606, 1993.
[46]  P. W. Barry and C. O'Callaghan, “The effect of delay, multiple actuations and spacer static charge on the in vitro delivery of budesonide from the Nebuhaler,” British Journal of Clinical Pharmacology, vol. 40, no. 1, pp. 76–78, 1995.
[47]  D. J. Clark and B. J. Lipworth, “Effect of multiple actuations, delayed inhalation and antistatic treatment on the lung bioavailability of salbutamol via a spacer device,” Thorax, vol. 51, no. 10, pp. 981–984, 1996.
[48]  P. W. Barry, C. F. Robertson, and C. O'Callaghan, “Optimum use of a spacer device,” Archives of Disease in Childhood, vol. 69, no. 6, pp. 693–694, 1993.
[49]  P. W. Barry and C. O'Callaghan, “Multiple actuations of salbutamol MDI into a spacer device reduce the amount of drug recovered in the respirable range,” European Respiratory Journal, vol. 7, no. 9, pp. 1707–1709, 1994.
[50]  J. L. Rau, R. D. Restrepo, and V. Deshpande, “Inhalation of single vs multiple metered-dose bronchodilator actuations from reservoir devices: an in vitro study,” Chest, vol. 109, no. 4, pp. 969–974, 1996.
[51]  G. Crompton and J. Duncan, “Clinical assessment of a new breath-actuated inhaler,” Practitioner, vol. 233, no. 1463, pp. 268–269, 1989.
[52]  G. Gross, R. M. Cohen, and H. Guy, “Efficacy response of inhaled HFA-albuterol delivered via the breath-actuated Autohaler inhalation device is comparable to dose in patients with asthma,” Journal of Asthma, vol. 40, no. 5, pp. 487–495, 2003.
[53]  D. Price, M. Thomas, G. Mitchell, C. Niziol, and R. Featherstone, “Improvement of asthma control with a breath-actuated pressurised metred dose inhaler (BAI): a prescribing claims study of 5556 patients using a traditional pressurised metred dose inhaler (MDI) or a breath-actuated device,” Respiratory Medicine, vol. 97, no. 1, pp. 12–19, 2003.
[54]  S. P. Newman, A. W. B. Weisz, N. Talaee, and S. W. Clarke, “Improvement of drug delivery with a breath actuated pressurised aerosol for patients with poor inhaler technique,” Thorax, vol. 46, no. 10, pp. 712–716, 1991.
[55]  D. R. Price, L. Pearce, S. R. Powell, J. Shirley, and M. K. Sayers, “Handling and acceptability of the Easi-Breathe device compared with a conventional metered dose inhaler by patients and practice nurses,” International Journal of Clinical Practice, vol. 53, no. 1, pp. 31–36, 1999.
[56]  B. J. Lipworth and D. J. Clark, “Lung delivery of salbutamol given by breath activated pressurized aerosol and dry powder inhaler devices,” Pulmonary Pharmacology and Therapeutics, vol. 10, no. 4, pp. 211–214, 1997.
[57]  http://www.admit-online.info/.
[58]  S. P. Newman and W. W. Busse, “Evolution of dry powder inhaler design, formulation, and performance,” Respiratory Medicine, vol. 96, no. 5, pp. 293–304, 2002.
[59]  N. Islam and E. Gladki, “Dry powder inhalers (DPIs)-A review of device reliability and innovation,” International Journal of Pharmaceutics, vol. 360, no. 1-2, pp. 1–11, 2008.
[60]  P. J. Atkins, “Dry powder inhalers: an overview,” Respiratory Care, vol. 50, no. 10, pp. 1304–1312, 2005.
[61]  W. Azouz and H. Chrystyn, “Clarifying the dilemmas about inhalation techniques for dry powder inhalers: integrating science with clinical practice,” Primary Care Respiratory Journal, 2012.
[62]  N. Islam and M. J. Cleary, “Developing an efficient and reliable dry powder inhaler for pulmonary drug delivery—a review for multidisciplinary researchers,” Medical Engineering and Physics, vol. 34, no. 4, pp. 409–427, 2012.
[63]  W. Janssens, P. VandenBrande, E. Hardeman et al., “Inspiratory flow rates at different levels of resistance in elderly COPD patients,” European Respiratory Journal, vol. 31, no. 1, pp. 78–83, 2008.
[64]  F. Lavorini, A. Magnan, J. Christophe Dubus et al., “Effect of incorrect use of dry powder inhalers on management of patients with asthma and COPD,” Respiratory Medicine, vol. 102, no. 4, pp. 593–604, 2008.
[65]  C. O'Callaghan and P. W. Barry, “The science of nebulised drug delivery,” Thorax, vol. 52, no. 2, pp. S31–S44, 1997.
[66]  D. R. Hess, “Nebulizers: principles and performance,” Respiratory Care, vol. 45, no. 6, pp. 609–622, 2000.
[67]  J. Boe, J. H. Dennis, and B. R. O'Driscoll, “European respiratory society guidelines on the use of nebulizers,” European Respiratory Journal, vol. 18, no. 1, pp. 228–242, 2001.
[68]  D. Hess, D. Fisher, P. Williams, S. Pooler, and R. M. Kacmarek, “Medication nebulizer performance: effects of diluent volume, nebulizer flow, and nebulizer brand,” Chest, vol. 110, no. 2, pp. 498–505, 1996.
[69]  M. L. Everard, M. Evans, and A. D. Milner, “Is tapping jet nebulisers worthwhile?” Archives of Disease in Childhood, vol. 70, no. 6, pp. 538–539, 1994.
[70]  R. A. Malone, M. C. Hollie, A. Glynn-Barnhart, and H. S. Nelson, “Optimal duration of nebulized albuterol therapy,” Chest, vol. 104, no. 4, pp. 1114–1118, 1993.
[71]  K. Nikander, “Adaptive aerosol delivery: the principles,” European Respiratory Review, vol. 7, no. 51, pp. 385–387, 1997.
[72]  J. Denyer, “Adaptive aerosol delivery in practice,” European Respiratory Review, vol. 7, no. 51, pp. 388–389, 1997.
[73]  R. E. Van Dyke and K. Nikander, “Delivery of iloprost inhalation solution with the halolite, prodose, and I-neb adaptive aerosol delivery systems: an in vitro study,” Respiratory Care, vol. 52, no. 2, pp. 184–190, 2007.
[74]  S. Skaria and G. C. Smaldone, “Omron NE U22: comparison between vibrating mesh and jet nebulizer,” Journal of Aerosol Medicine and Pulmonary Drug Delivery, vol. 23, no. 3, pp. 173–180, 2010.
[75]  R. Dhand, “Nebulizers that use a vibrating mesh or plate with multiple apertures to generate aerosol,” Respiratory Care, vol. 47, no. 12, pp. 1406–1416, 2002.
[76]  A. L. Coates, M. Green, K. Leung et al., “A comparison of amount and speed of deposition between the PARI LC STAR jet nebulizer and an investigational eFlow nebulizer,” Journal of Aerosol Medicine and Pulmonary Drug Delivery, vol. 24, no. 3, pp. 157–163, 2011.
[77]  S. Naehrig, S. Lang, H. Schiffl, R. M. Huber, and R. Fischer, “Lung function in adult patients with cystic fibrosis after using the eFlow rapid for one year,” European Journal of Medical Research, vol. 16, no. 2, pp. 63–66, 2011.
[78]  G. C. Smaldone, S. Sangwan, and A. Shah, “Facemask design, facial deposition, and delivered dose of nebulized aerosols,” Journal of Aerosol Medicine, vol. 20, no. 1, pp. S66–S75, 2007.
[79]  S. Erzinger, K. G. Schueepp, J. Brooks-Wildhaber, S. G. Devadason, and J. H. Wildhaber, “Facemasks and Aerosol delivery in vivo,” Journal of Aerosol Medicine, vol. 20, no. 1, pp. S78–S83, 2007.
[80]  S. Sangwan, B. K. Gurses, and G. C. Smaldone, “Facemasks and facial deposition of aerosols,” Pediatric Pulmonology, vol. 37, no. 5, pp. 447–452, 2004.
[81]  R. Dalby, M. Spallek, and T. Voshaar, “A review of the development of Respimat Soft Mist Inhaler,” International Journal of Pharmaceutics, vol. 283, no. 1-2, pp. 1–9, 2004.
[82]  F. K?ssner, R. Hodder, and E. D. Bateman, “A review of ipratropium bromide/fenoterol hydrobromide (Berodual) delivered via Respimat Soft Mist Inhaler in patients with asthma and chronic obstructive pulmonary disease,” Drugs, vol. 64, no. 15, pp. 1671–1682, 2004.
[83]  J. Haughney, D. Price, N. C. Barnes, J. C. Virchow, N. Roche, and H. Chrystyn, “Choosing inhaler devices for people with asthma: current knowledge and outstanding research needs,” Respiratory Medicine, vol. 104, no. 9, pp. 1237–1245, 2010.
[84]  C. C. Cates, A. Bara, J. A. Crilly, and B. H. Rowe, “Holding chambers versus nebulisers for beta-agonist treatment of acute asthma,” Cochrane Database of Systematic Reviews, no. 3, Article ID CD000052, 2003.
[85]  C. Cates, “Spacers and nebulisers for the delivery of beta-agonists in non-life-threatening acute asthma,” Respiratory Medicine, vol. 97, no. 7, pp. 762–769, 2003.
[86]  D. Brocklebank, F. Ram, J. Wright et al., “Comparison of the effectiveness of inhaler devices in asthma and chronic obstructive airways disease: a systematic review of the literature,” Health Technology Assessment, vol. 5, no. 26, p. -139, 2001.
[87]  M. O. Turner, A. Patel, S. Ginsburg, and J. M. FitzGerald, “Bronchodilator delivery in acute airflow obstruction: a meta-analysis,” Archives of Internal Medicine, vol. 157, no. 15, pp. 1736–1744, 1997.
[88]  I. Amirav and M. T. Newhouse, “Metered-dose inhaler accessory devices in acute asthma: efficacy and comparison with nebulizers. A literature review,” Archives of Pediatrics and Adolescent Medicine, vol. 151, no. 9, pp. 876–882, 1997.
[89]  J. Christian Virchow, “What plays a role in the choice of inhaler device for asthma therapy?” Current Medical Research and Opinion, vol. 21, no. 4, pp. S19–S25, 2005.
[90]  K. R. Chapman, T. H. Voshaar, and J. C. Virchow, “Inhaler choice in primary practice,” European Respiratory Review, vol. 14, no. 96, pp. 117–122, 2005.
[91]  P. L. Brand, “Key issues in inhalation therapy in children,” Current Medical Research and Opinion, vol. 21, supplement 4, pp. s27–s32, 2005.
[92]  J. B. Fink, “Inhalers in asthma management: is demonstration the key to compliance?” Respiratory Care, vol. 50, no. 5, pp. 598–600, 2005.
[93]  P. G. Gibson, F. S. F. Ram, and H. Powell, “Asthma education,” Respiratory Medicine, vol. 97, no. 9, pp. 1036–1044, 2003.
[94]  W. C. Bailey, J. M. Richards Jr., C. M. Brooks, S. Soong, R. A. Windsor, and B. A. Manzella, “A randomized trial to improve self-management practices of adults with asthma,” Archives of Internal Medicine, vol. 150, no. 8, pp. 1664–1668, 1990.
[95]  I. A. Basheti, H. K. Reddel, C. L. Armour, and S. Z. Bosnic-Anticevich, “Improved asthma outcomes with a simple inhaler technique intervention by community pharmacists,” Journal of Allergy and Clinical Immunology, vol. 119, no. 6, pp. 1537–1538, 2007.
[96]  A. J. Burton, “Asthma inhalation devices: what do we know?” British Medical Journal, vol. 288, no. 6431, pp. 1650–1651, 1984.
[97]  B. Interiano and K. K. Guntupalli, “Metered-dose inhalers: do health care providers know what to teach?” Archives of Internal Medicine, vol. 153, no. 1, pp. 81–85, 1993.
[98]  M. E. A. C. Broeders, J. Sanchis, M. L. Levy, G. K. Crompton, and P. N. R. Dekhuijzen, “The ADMIT series—issues in inhalation therapy. 2) Improving technique and clinical effectiveness,” Primary Care Respiratory Journal, vol. 18, no. 2, pp. 76–82, 2009.
[99]  S.-H. Kim, H. J. Kwak, T.-B. Kim et al., “Inappropriate techniques used by internal medicine residents with three kinds of inhalers (a metered dose inhaler, diskus, and turbuhaler): changes after a single teaching session,” Journal of Asthma, vol. 46, no. 9, pp. 944–950, 2009.
[100]  I. A. Basheti, C. L. Armour, H. K. Reddel, and S. Z. Bosnic-Anticevich, “Long-term maintenance of pharmacists' inhaler technique demonstration skills,” American Journal of Pharmaceutical Education, vol. 73, no. 2, article 32, 2009.
[101]  M. Duerden and D. Price, “Training issues in the use of inhalers,” Disease Management and Health Outcomes, vol. 9, no. 2, pp. 75–87, 2001.
[102]  J. van der Palen, J. J. Klein, A. H. Kerkhoff, C. L. van Herwaarden, and E. R. Seydel, “Evaluation of the long-term effectiveness of three instruction modes of inhaling medicines,” Patient Education and Counseling, vol. 32, supplement 1, pp. S87–S95, 1997.
[103]  P. De Blaquiere, D. B. Christensen, W. B. Carter, and T. R. Martin, “Use and misuse of metered-dose inhalers by patients with chronic lung disease: a controlled, randomized trial of two instruction methods,” American Review of Respiratory Disease, vol. 140, no. 4, pp. 910–916, 1989.
[104]  C. J. R. Nimmo, D. N. M. Chen, S. M. Martinusen et al., “Assessment of patient acceptance and inhalation technique of a pressurized aerosol inhaler and two breath-actuated devices,” Annals of Pharmacotherapy, vol. 27, no. 7-8, pp. 922–927, 1993.
[105]  A. Hardwell, V. Barber, T. Hargadon, E. McKnight, J. Holmes, and M. L. Levy, “Technique training does not improve the ability of most patients to use pressurised metered-dose inhalers (pMDIs),” Primary Care Respiratory Journal, vol. 20, no. 1, pp. 92–96, 2011.
[106]  M. Takemura, M. Kobayashi, K. Kimura et al., “Repeated instruction on inhalation technique improves adherence to the therapeutic regimen in asthma,” Journal of Asthma, vol. 47, no. 2, pp. 202–208, 2010.
[107]  S. L. Gray, D. M. Williams, C. C. Pulliam, M. A. Sirgo, A. L. Bishop, and J. F. Donohue, “Characteristics predicting incorrect metered-dose inhaler technique in older subjects,” Archives of Internal Medicine, vol. 156, no. 9, pp. 984–988, 1996.
[108]  L. Agertoft and S. Pedersen, “Importance of training for correct Turbuhaler use in preschool children,” Acta Paediatrica, International Journal of Paediatrics, vol. 87, no. 8, pp. 842–847, 1998.
[109]  J. van der Palen, J. J. Klein, C. L. A. van Herwaarden, G. A. Zielhuis, and E. R. Seydel, “Multiple inhalers confuse asthma patients,” European Respiratory Journal, vol. 14, no. 5, pp. 1034–1037, 1999.
[110]  M. Molimard and V. L. Gros, “Impact of patient-related factors on asthma control,” Journal of Asthma, vol. 45, no. 2, pp. 109–113, 2008.
[111]  R. A. M. Al-Showair, S. B. Pearson, and H. Chrystyn, “The potential of a 2Tone trainer to help patients use their metered-dose inhalers,” Chest, vol. 131, no. 6, pp. 1776–1782, 2007.
[112]  F. Lavorini, M. L. Levy, C. Corrigan, and G. Crompton, “The ADMIT series-issues in inhalation therapy. 6) training tools for inhalation devices,” Primary Care Respiratory Journal, vol. 19, no. 4, pp. 335–341, 2010.
[113]  M. Thomas, D. Price, H. Chrystyn, A. Lloyd, A. E. Williams, and J. von Ziegenweidt, “Inhaled corticosteroids for asthma: impact of practice level device switching on asthma control,” BMC Pulmonary Medicine, vol. 9, p. 1, 2009.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133