全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

Transcatheter Coil Embolization of a Coronary Artery-Left Ventricular Fistula Associated with Single Coronary Artery Anomaly

DOI: 10.1155/2014/865490

Full-Text   Cite this paper   Add to My Lib

Abstract:

Single coronary artery anomaly associated with coronary fistula is a rare entity. Transcatheter coil embolization is the treatment of choice for coronary artery fistulas. In this case report, we describe a patient with both single coronary artery anomaly and coronary fistula who was successfully treated with coil embolization. 1. Introduction Congenital coronary artery fistula is defined as a rare anomalous connection between a coronary artery and a major vessel or a cardiac chamber. It is a rare condition and is frequently diagnosed incidentally. Treatment of a congenital coronary artery fistula is a challenge for cardiologist. 2. Case Report A 56-year-old male was admitted to our institution with anginal chest pain lasting for 3 months. He had no history of cardiac disease and no cardiac risk factors. Examination of cardiovascular system revealed a continuous murmur in the left parasternal border. The remainder of the examination was unremarkable. 12-lead surface electrocardiogram was normal. Transthoracic echocardiography revealed hypokinesia of inferior wall and mild mitral regurgitation. Left ventricular ejection fraction calculated by modified Simpson’s method was 52%. In the light of these findings, selective coronary angiography was performed. A single coronary artery was arising from the right sinus of valsalva and terminating with fistulisation into a cardiac chamber (Figure 1). Anomalous coronary artery was dilated and no significant stenosis was encountered in any of the coronary arteries imaged. Multislice computed tomography showed origins of all coronary arteries arising from the right sinus of valsalva with a single ostium (Figure 2). The course of the anomalous coronary artery was not between the pulmonary and aortic trunci. Percutaneously, catheter-based coil embolization was performed to occlude the fistula. A standard 8-F guiding catheter was inserted into the right sinus of valsalva. A floppy guidewire was placed into the fistula and a microcatheter was advanced over the guidewire. The guidewire was withdrawn and a detachable coil was placed into the proximal part of the fistula. After embolization of coil, coronary angiography showed satisfactory result with the fistula’s stump only (Figure 3). A day after the procedure the patient was discharged without any complication. The patient was free of symptoms during months of follow-up. Figure 1: Coronary cine angiogram. Left anterior oblique projection shows a single large right coronary artery originated from the right aortic sinus and extended to the left and terminating with a

References

[1]  B. G. Alekyan, V. P. Podzolkov, and C. E. Cárdenas, “Transcatheter coil embolization of coronary artery fistula,” Asian Cardiovascular and Thoracic Annals, vol. 10, no. 1, pp. 47–52, 2002.
[2]  R. M. Gowda, B. C. Vasavada, and I. A. Khan, “Coronary artery fistulas: clinical and therapeutic considerations,” International Journal of Cardiology, vol. 107, no. 1, pp. 7–10, 2006.
[3]  S. Balanescu, G. Sangiorgi, S. Castelvecchio, M. Medda, and L. Inglese, “Coronary artery fistulas: clinical consequences and methods of closure. A literature review,” Italian Heart Journal, vol. 2, no. 9, pp. 669–676, 2001.
[4]  B. A. Cason and H. J. Gordon, “Coronary steal caused by a coronary artery fistula,” Journal of Cardiothoracic and Vascular Anesthesia, vol. 6, no. 1, pp. 65–67, 1992.
[5]  T. Niizeki, H. Daidouji, Y. Ootaki et al., “Transcatheter coil embolization of coronary artery fistulaes: case report,” Journal of Cardiology Cases, vol. 61, pp. e1–e4, 2010.
[6]  Y. Ata, T. Turk, M. Bicer, M. Yalcin, F. Ata, and S. Yavuz, “Coronary arteriovenous fistulas in the adults: natural history and management strategies,” Journal of Cardiothoracic Surgery, vol. 4, article 62, 2009.