Heat Transfer Augmentation Technologies for Internal Cooling of Turbine Components of Gas Turbine Engines

DOI: 10.1155/2013/275653

Full-Text   Cite this paper   Add to My Lib

Abstract:

To provide an overview of the current state of the art of heat transfer augmentation schemes employed for internal cooling of turbine blades and components, results from an extensive literature review are presented with data from internal cooling channels, both with and without rotation. According to this survey, a very small number of existing investigations consider the use of combination devices for internal passage heat transfer augmentation. Examples are rib turbulators, pin fins, and dimples together, a combination of pin fins and dimples, and rib turbulators and pin fins in combination. The results of such studies are compared with data obtained prior to 2003 without rotation influences. Those data are comprised of heat transfer augmentation results for internal cooling channels, with rib turbulators, pin fins, dimpled surfaces, surfaces with protrusions, swirl chambers, or surface roughness. This comparison reveals that all of the new data, obtained since 2003, collect within the distribution of globally averaged data obtained from investigations conducted prior to 2003 (without rotation influences). The same conclusion in regard to data distributions is also reached in regard to globally averaged thermal performance parameters as they vary with friction factor ratio. These comparisons, made on the basis of such judgment criteria, lead to the conclusion that improvements in our ability to provide better spatially-averaged thermal protection have been minimal since 2003. When rotation is present, existing investigations provide little evidence of overall increases or decreases in overall thermal performance characteristics with rotation, at any value of rotation number, buoyancy parameter, density ratio, or Reynolds number. Comparisons between existing rotating channel experimental data and the results obtained prior to 2003, without rotation influences, also show that rotation has little effect on overall spatially-averaged thermal performance as a function of friction factor. 1. Introduction The techniques employed to enhance convective heat transfer rates for internal cooling of turbine airfoils of gas turbine engines include rib turbulators, pin fins, dimpled surfaces, surfaces with arrays of protrusions, swirl chambers, and surface roughness [1]. According to Ligrani et al. [1], all of these devices act to increase secondary flows and turbulence levels to enhance mixing, in some cases, to form coherent fluid motions in the form of streamwise-oriented vortices. Such vortices and secondary flows not only act to increase secondary advection of

References

[1]  P. M. Ligrani, M. M. Oliveira, and T. Blaskovich, “Comparison of heat transfer augmentation techniques,” AIAA Journal, vol. 41, no. 3, pp. 337–362, 2003.
[2]  J. C. Han, S. Dutta, and S. Ekkad, Gas Turbine Heat Transfer and Cooling Technology, Taylor and Francis, New York, NY, USA, 2000.
[3]  J. C. Han, J. S. Park, and C. K. Lie, “Heat Transfer and pressure drop in blade cooling channels with turbulence promoters,” NASA CR-3837, 1984.
[4]  A. Murata, S. Nishida, H. Saito, K. Iwamoto, Y. Okita, and C. Nakamata, “Heat transfer enhancement due to combination of dimples, protrusions, and ribs in narrow internal passage of gas turbine blade,” ASME Paper GT2011-45356, 2011.
[5]  Y. Rao, C. Wan, Y. Xu, and S. Zang, “Local heat transfer characteristics in channels with pin fin and pin fin-dimple arrays,” ASME Paper GT2011-45449, 2011.
[6]  S. C. Siw, M. K. Chyu, and M. A. Alvin, “Effects of pin detached space on heat transfer in a rib roughened channel,” ASME Paper GT2011-46078, 2011.
[7]  B. A. Brigham and G. J. VanFossen, “Length to diameter ratio and row number effects in short pin fin heat transfer,” Journal of Engineering for Gas Turbines and Power, vol. 106, no. 1, pp. 241–245, 1984.
[8]  P. M. Ligrani and G. I. Mahmood, “Variable property Nusselt numbers in a channel with pin fins,” Journal of Thermophysics and Heat Transfer, vol. 17, no. 1, pp. 103–111, 2003.
[9]  S. C. Siw, M. K. Chyu, and M. A. Alvin, “Heat transfer enhancement of internal cooling passage with triangular and semi-circular shaped pin-fin arrays,” ASME Paper GT2012-69266, 2012.
[10]  B. Sundén, G. Xie, and Q. Wang, “Predictions of enhanced heat transfer of an internal blade tip-wall with hemispherical dimples or protrusions,” ASME Paper GT2010-22265, 2010.
[11]  W. Chen, J. Ren, and H. Jiang, “Effect of turning vane configurations on heat transfer and pressure drop in a ribbed internal cooling system,” ASME Paper GT2010-22273, 2010.
[12]  D. E. Metzger, R. A. Barry, and J. P. Bronson, “Developing heat transfer in rectangular ducts with staggered arrays of short pin-fins,” Journal of Heat Transfer, vol. V 104, no. 4, pp. 700–706, 1982.
[13]  D. E. Metzger and S. W. Haley, “Heat transfer experiments and flow visualization for arrays of short pin-fins,” ASME Paper 82-GT-138, 1982.
[14]  E. M. Sparrow, J. W. Ramsey, and C. A. C. Altemani, “Experiments on in-line pin fin arrays and performance comparisons with staggered array,” Journal of Heat Transfer, vol. 102, no. 1, pp. 44–50, 1980.
[15]  A. Zukauskas, “Heat transfer from tubes in cross flow,” Advances in Heat Transfer, vol. 8, pp. 96–160, 1972.
[16]  G. J. VanFossen, “Heat-transfer coefficients for staggered arrays of short pin-fins,” Journal of Engineering for Power, vol. 104, no. 2, pp. 268–274, 1982.
[17]  R. J. Simoneau and G. J. VanFossen, “Effects of location in an array on heat transfer to a short cylinder in cross flow,” Journal of Heat Transfer, vol. 106, no. 1, pp. 42–48, 1984.
[18]  S. C. Lau, J. C. Han, and Y. S. Kim, “Turbulent heat transfer and friction in pin fin channels with lateral flow ejection,” Journal of Heat Transfer, vol. 111, no. 1, pp. 51–58, 1989.
[19]  R. D. McMillin and S. C. Lau, “Effect of trailing-edge ejection on local heat (mass) transfer in pin fin cooling channels in turbine blades,” Journal of Turbomachinery, vol. 116, no. 1, pp. 159–168, 1994.
[20]  M. K. Chyu, “Heat transfer and pressure drop for short pin-fin arrays with pin-endwall fillet,” Journal of Heat Transfer, vol. 112, no. 4, pp. 926–932, 1990.
[21]  M. K. Chyu and R. J. Goldstein, “Influence of an array of wall-mounted cylinders on the mass transfer from a flat surface,” International Journal of Heat and Mass Transfer, vol. 34, no. 9, pp. 2175–2186, 1991.
[22]  M. K. Chyu, Y. C. Hsing, T. I. P. Shih, and V. Natarajan, “Heat transfer contributions of pins and endwall in pin-fin arrays: effects of thermal boundary condition modeling,” Journal of Turbomachinery, vol. 121, no. 2, pp. 257–263, 1999.
[23]  V. B. Grannis and E. M. Sparrow, “Numerical simulation of fluid flow through an array of diamond-shaped pin fins,” Numerical Heat Transfer A, vol. 19, no. 4, pp. 381–403, 1991.
[24]  D. A. Olson, “Heat transfer in thin, compact heat exchangers with circular, rectangular, or pin-fin flow passages,” Journal of Heat Transfer, vol. 114, no. 2, pp. 373–382, 1992.
[25]  M. K. Chyu, Y. C. Hsing, and V. Natarajan, “Convective heat transfer of cubic fin arrays in a narrow channel,” Journal of Turbomachinery, vol. 120, no. 2, pp. 362–367, 1998.
[26]  M. K. Chyu and V. Natarajan, “Heat transfer on the base surface of three-dimensional protruding elements,” International Journal of Heat and Mass Transfer, vol. 39, no. 14, pp. 2925–2935, 1996.
[27]  J. J. Hwang and C. C. Lu, “Lateral-flow effect on endwall heat transfer and pressure drop in a pin-fin trapezoidal duct of various pin shapes,” ASME Paper 2000-GT-232, 2000.
[28]  O. Uzol and C. Camci, “Elliptical pin fins as an alternative to circular pin fins for gas turbine blade cooling applications. Part 1: endwall heat transfer and total pressure loss characteristics,” ASME Paper 2001-GT-180, 2001.
[29]  O. Uzol and C. Camci, “Elliptical pin fins as an alternative to circular pin fins for gas turbine blade cooling applications. Part 2: wake flow field measurements and visualization using particle image velocimetry,” ASME Paper 2001-GT-181, 2001.
[30]  S. Y. Won, G. I. Mahmood, and P. M. Ligrani, “Spatially-resolved heat transfer and flow structure in a rectangular channel with pin fins,” International Journal of Heat and Mass Transfer, vol. 47, no. 8-9, pp. 1731–1743, 2004.
[31]  V. N. Murzin, S. A. Stoklitskii, and A. P. Chebotarev, “Creation of solitary vortices in a flow around shallow spherical depressions,” Soviet Technical Physical Letters, vol. 12, no. 11, pp. 547–549, 1986.
[32]  P. R. Gromov, A. B. Zobnin, M. I. Rabinovich, and M. M. Sushchik, “Creation of solitary vortices in a flow around shallow spherical depressions,” Soviet Technical Physical Letters, vol. 12, no. 11, pp. 1323–1328, 1986.
[33]  V. S. Kesarev and A. P. Kozlov, “Convective heat transfer in turbulized flow past a hemispherical cavity,” Heat Transfer Research, vol. 25, no. 2, pp. 156–160, 1993.
[34]  V. N. Afanasyev, Y. P. Chudnovsky, A. I. Leontiev, and P. S. Roganov, “Turbulent flow friction and heat transfer characteristics for spherical cavities on a flat plate,” Experimental Thermal and Fluid Science, vol. 7, no. 1, pp. 1–8, 1993.
[35]  M. Y. Belen'kiy, M. A. Gotovskiy, B. M. Lekakh, B. S. Fokin, and K. S. Dolgushin, “Heat transfer augmentation using surfaces formed by a system of spherical cavities,” Heat Transfer Research, vol. 25, no. 2, pp. 196–203, 1993.
[36]  V. I. Terekhov, S. V. Kalinina, and Y. M. Mshvidobadze, “Flow structure and heat transfer on a surface with a unit hole depression,” Russian Journal of Engineering Thermophysics, vol. 5, pp. 11–34, 1995.
[37]  V. D. Zhak, “The taylor-goertler vortices and three-dimensional flow evolution in a cavity,” Russian Journal of Engineering Thermophysics, vol. 5, pp. 165–176, 1995.
[38]  A. V. Schukin, A. P. Kozlov, and R. S. Agachev, “Study and application of hemispheric cavities for surface heat transfer augmentation,” ASME Paper 95-GT-59, 1995.
[39]  P. W. Bearman and J. K. Harvey, “Control of circular cylinder flow by the use of dimples,” AIAA Journal, vol. 31, no. 10, pp. 1753–1756, 1993.
[40]  T. Kimura and M. Tsutahara, “Fluid dynamic effects of grooves on circular cylinder surface,” AIAA Journal, vol. 29, no. 12, pp. 2062–2068, 1991.
[41]  M. E. Kithcart and D. E. Klett, “Heat transfer and skin friction comparison of dimpled versus protrusion roughness,” Journal of Enhanced Heat Transfer, vol. 3, no. 4, pp. 273–280, 1996.
[42]  M. K. Chyu, Y. Yu, H. Ding, J. P. Downs, and F. O. Soechting, “Concavity enhanced heat transfer in an internal cooling passage,” ASME Paper 97-GT-437, 1997.
[43]  Y. L. Lin, T. I.-P. Shih, and M. K. Chyu, “Computations of flow and heat transfer in a channel with rows of hemispherical cavities,” ASME Paper 99-GT-263, 1999.
[44]  Y. F. Gortyshov, I. A. Popov, R. D. Amirkhanov, and K. E. Gulitsky, “Studies of hydrodynamics and heat exchange in channels with various types of intensifiers,” in Proceedings of 11th International Heat Transfer Congress (IHTC '98), vol. 6, pp. 83–88, 1998.
[45]  H. K. Moon, T. O’Connell, and B. Glezer, “Channel height effect on heat transfer and friction in a dimpled passage,” ASME Paper 99-GT-163, 1999.
[46]  J. Chen, H. Müller-Steinhagen, and G. G. Duffy, “Heat transfer enhancement in dimpled tubes,” Applied Thermal Engineering, vol. 21, no. 5, pp. 535–547, 2001.
[47]  S. W. Moon and S. C. Lau, “Turbulent heat transfer measurements on a wall with concave and cylindrical dimples in a square channel,” ASME Paper GT-2002-30208, 2002.
[48]  G. I. Mahmood, M. L. Hill, D. L. Nelson, P. M. Ligrani, H. K. Moon, and B. Glezer, “Local heat transfer and flow structure on and above a dimpled surface in a channel,” Journal of Turbomachinery, vol. 123, no. 1, pp. 115–123, 2001.
[49]  G. I. Mahmood and P. M. Ligrani, “Heat transfer in a dimpled channel: combined influences of aspect ratio, temperature ratio, Reynolds number, and flow structure,” International Journal of Heat and Mass Transfer, vol. 45, no. 10, pp. 2011–2020, 2002.
[50]  M. Elfert, M. Voges, and J. Klinner, “Detailed flow investigation using PIV in a rotating square-sectioned two-pass cooling system with ribbed walls,” ASME Paper GT2008-51183, 2008.
[51]  N. K. Burgess and P. M. Ligrani, “Effects of dimple depth on channel nusselt numbers and friction factors,” Journal of Heat Transfer, vol. 127, no. 8, pp. 839–847, 2005.
[52]  P. M. Ligrani, J. L. Harrison, G. I. Mahmmod, and M. L. Hill, “Flow structure due to dimple depressions on a channel surface,” Physics of Fluids, vol. 13, no. 11, pp. 3442–3451, 2001.
[53]  G. I. Mahmood, M. Z. Sabbagh, and P. M. Ligrani, “Heat transfer in a channel with dimples and protrusions on opposite walls,” Journal of Thermophysics and Heat Transfer, vol. 15, no. 3, pp. 275–283, 2001.
[54]  P. M. Ligrani, G. I. Mahmood, J. L. Harrison, C. M. Clayton, and D. L. Nelson, “Flow structure and local Nusselt number variations in a channel with dimples and protrusions on opposite walls,” International Journal of Heat and Mass Transfer, vol. 44, no. 23, pp. 4413–4425, 2001.
[55]  S. A. Isaev, A. I. Leont'ev, and P. A. Baranov, “Identification of self-organized vortexlike structures in numerically simulated turbulent flow of a viscous incompressible liquid streaming around a well on a plane,” Technical Physics Letters, vol. 26, no. 1, pp. 15–18, 2000.
[56]  M. Al-Qahtani, H.-C. Chen, and J. C. Han, “A numerical study of flow and heat transfer in rotating rectangular channels (AR=4) with 45° Rib turbulators by reynolds stress turbulence model,” ASME Paper GT-2002-30216, 2002.
[57]  M. Al-Qahtani, Y. Jang, H. C. Chen, and J. C. Han, “Prediction of flow and heat transfer in rotating two-pass rectangular channels with 45° Rib turbulators,” ASME Paper 2001-GT-187, 2001.
[58]  G. S. Azad, M. J. Uddin, J. C. Han, H. K. Moon, and B. Glezer, “Heat transfer in a two-pass rectangular rotating channel with 45-deg angleb rib turbulators,” Journal of Turbomachinery, vol. 124, no. 2, pp. 251–259, 2002, ASME Paper 2001-GT-186.
[59]  B. Bonhoff, S. Parneix, J. Leusch, B. V. Johnson, J. Schabacker, and A. B?lcs, “Experimental and numerical study of developed flow and heat transfer in coolant channels with 45 degree ribs,” International Journal of Heat and Fluid Flow, vol. 20, no. 3, pp. 311–319, 1999.
[60]  B. Bonhoff, U. Tomm, B. V. Johnson, and I. Jennions, “Heat transfer predictions for rotating U-shaped coolant channels with skewed ribs and with smooth walls,” ASME Paper 97-GT-162, 1997.
[61]  R. S. Bunker, T. G. Wetzel, and D. L. Rigby, “Heat transfer in a complex trailing edge passage for a high pressure turbine blade—part 1: experimental measurements,” ASME Paper GT-2002-30212, 2002.
[62]  L. Casarsa, M. Cakan, and T. Arts, “Characterization of the velocity and heat transfer fields in an internal cooling channel with high blockage ratio,” ASME Paper GT-2002-30207, 2002.
[63]  H. H. Cho, S. Y. Lee, and S. J. Wu, “The combined effects of rib arrangements and discrete ribs on local heat/mass transfer in a square duct,” ASME Paper 2001-GT-175, 2001.
[64]  S. Dutta and J. C. Han, “Local heat transfer in rotating smooth and ribbed two-pass square channels with three channel orientations,” Journal of Heat Transfer, vol. 118, no. 3, pp. 578–584, 1996.
[65]  S. Dutta, J. C. Han, and C. P. Lee, “Local heat transfer in a rotating two-pass ribbed triangular duct with two model orientations,” International Journal of Heat and Mass Transfer, vol. 39, no. 4, pp. 707–715, 1996.
[66]  F. Shin, Y. Wen-Jei, and Z. Nengli, “Local heat transfer in a rotating serpentine passage with rib-roughened surfaces,” International Journal of Heat and Mass Transfer, vol. 37, no. 2, pp. 217–228, 1994.
[67]  T. S. Griffith, L. Al-Hadhrami, and J. C. Han, “Heat transfer in rotating rectangular cooling channels (AR=4) with angled ribs,” Journal of Heat Transfer, vol. 124, no. 4, pp. 617–625, 2002.
[68]  J. C. Han, L. R. Glicksman, and W. M. Rohsenow, “An investigation of heat transfer and friction for rib-roughened surfaces,” International Journal of Heat and Mass Transfer, vol. 21, no. 8, pp. 1143–1156, 1978.
[69]  J. C. Han, J. J. Huang, and C. P. Lee, “Augmented heat transfer in square channels with wedge-shaped and delta-shaped turbulence promoters,” Journal of Enhanced Heat Transfer, vol. 1, no. 1, pp. 37–52, 1993.
[70]  J. C. Han and J. S. Park, “Developing heat transfer in rectangular channels with rib turbulators,” International Journal of Heat and Mass Transfer, vol. 31, no. 1, pp. 183–195, 1988.
[71]  J. C. Han, Y. M. Zhang, and C. P. Lee, “Augmented heat transfer in square channels with parallel, crossed, and V-shaped angled ribs,” Journal of Heat Transfer, vol. 113, no. 3, pp. 590–596, 1991.
[72]  H. Iacovides, “Computation of flow and heat transfer through rotating ribbed passages,” International Journal of Heat and Fluid Flow, vol. 19, no. 5, pp. 393–400, 1998.
[73]  R. Jia, A. Saidi, and B. Sunden, “Heat transfer enhancement in square ducts with V-shaped Ribs of various angles,” ASME Paper GT-2002-30209, 2002.
[74]  B. V. Johnson, J. H. Wagner, G. D. Steuber, and F. C. Yeh, “Heat transfer in rotating serpentine passages with trips skewed to the flow,” Journal of Turbomachinery, vol. 116, no. 1, pp. 113–123, 1994, ASME Paper 92-GT-191.
[75]  B. V. Johnson, J. H. Wagner, G. D. Steuber, and F. C. Yeh, “Heat transfer in rotating serpentine passages with selected model orientations for smooth or skewed trip walls,” Journal of Turbomachinery, vol. 116, no. 4, pp. 738–744, 1994, ASME Paper 93-GT-305.
[76]  Y. L. Lin, T. I. P. Shih, M. A. Stephens, and M. K. Chyu, “A numerical study of flow and heat transfer in a smooth and ribbed u-duct with and without rotation,” Journal of Heat Transfer, vol. 123, no. 2, pp. 219–232, 2001.
[77]  T. M. Liou, M. Y. Chen, and Y. M. Wang, “Heat transfer, fluid flow, and pressure measurements inside a rotating two-pass duct with detached 90-deg ribs,” Journal of Turbomachinery, vol. 125, no. 3, pp. 565–574, 2003, ASME Paper GT-2002-30201.
[78]  G. I. Mahmood, P. M. Ligrani, and S. Y. Won, “Spatially-resolved heat transfer and flow structure in a rectangular channel with 45° angled rib turbulators,” ASME Paper GT-2002-30215, 2002.
[79]  C. W. Park, S. C. Lau, and R. T. Kukreja, “Effect of rib size on heat (Mass) transfer distribution in a rotating channel,” ASME Paper 97-AA-126, 1997.
[80]  C. W. Park, S. C. Lau, and R. T. Kukreja, “Heat (mass) transfer in a rotating channel with ribs of various sizes on two walls,” Journal of Thermophysics and Heat Transfer, vol. 12, no. 3, pp. 452–454, 1998.
[81]  J. A. Parsons, J. C. Han, and Y. M. Zhang, “Wall heating effect on local heat transfer in a rotating two-pass square channel with 90° rib turbulators,” International Journal of Heat and Mass Transfer, vol. 37, no. 9, pp. 1411–1420, 1994.
[82]  J. A. Parsons, J. C. Han, and Y. Zhang, “Effect of model orientation and wall heating condition on local heat transfer in a rotating two-pass square channel with rib turbulators,” International Journal of Heat and Mass Transfer, vol. 38, no. 7, pp. 1151–1159, 1995.
[83]  S. V. Prabhu and R. P. Vedula, “Pressure drop distribution in a rotating rectangular channel with one ribbed surface,” ASME Paper 97-AA-118, 1997.
[84]  D. L. Rigby, “Prediction of heat and mass transfer in a rotating ribbed coolant passage with a 180 degree turn,” ASME Paper 98-GT-329, 1998.
[85]  D. L. Rigby and R. S. Bunker, “Heat transfer in a complex trailing edge passage for a high pressure turbine blade—part 2: simulation results,” ASME Paper GT-2002-30213, 2002.
[86]  D. L. Rigby, E. Steinthorsson, and A. A. Ameri, “Numerical prediction of heat transfer in a channel with ribs and bleed,” ASME Paper 97-GT-431, 1997.
[87]  J. Schabacker, A. Bolcs, and B. V. Johnson, “PIV investigation of the flow characteristics in an internal coolant passage with 45 rib arrangement,” ASME Paper 99-GT-120, 1999.
[88]  T. I.-P. Shih, Y.-L. Lin, M. A. Stephens, and M. K. Chyu, “Flow and heat transfer in a ribbed U-duct under typical engine conditions,” ASME Paper 98-GT-213, 1998.
[89]  M. A. Stephens, M. K. Chyu, and T. I.-P. Shih, “Computations of convective heat transfer in a square duct with inclined ribs of rounded cross section,” ASME Paper 96-WA/HT-12, 1996.
[90]  M. A. Stephens and T. I.-P. Shih, “Computation of compressible flow and heat transfer in a rotating duct with inclined ribs and 180 degree bend,” ASME Paper 97-GT-192, 1997.
[91]  M. E. Taslim, L. A. Bondi, and D. M. Kercher, “Experimental investigation of heat transfer in an orthogonally rotating channel roughened with 45 deg criss-cross ribs on two opposite walls,” Journal of Turbomachinery, vol. 113, no. 3, pp. 346–353, 1991, ASME Paper 90-GT-332.
[92]  M. E. Taslim, T. Li, and D. M. Kercher, “Experimental heat transfer and friction in channels roughened with angled, V-shaped, and discrete ribs on two opposite walls,” Journal of Turbomachinery, vol. 118, no. 1, pp. 20–28, 1996.
[93]  M. E. Taslim, T. Li, and S. D. Spring, “Measurements of heat transfer coefficients and friction factors in passages rib-roughened on all walls,” Journal of Turbomachinery, vol. 120, no. 3, pp. 564–570, 1998.
[94]  M. E. Taslim and A. Lengkong, “45° staggered rib heat transfer coefficient measurements in a square channel,” Journal of Turbomachinery, vol. 120, no. 3, pp. 571–580, 1998.
[95]  M. E. Taslim, A. Rahman, and S. D. Spring, “Experimental investigation of heat transfer coefficients in a spanwise rotating channel with two opposite rib-roughened walls,” Journal of Turbomachinery, vol. 113, no. 1, pp. 75–82, 1991, ASME Paper 89-GT-150.
[96]  M. E. Taslim and C. M. Wadsworth, “An experimental investigation of the rib surface-averaged heat transfer coefficient in a rib-roughened square passage,” Journal of Turbomachinery, vol. 119, no. 2, pp. 381–389, 1997.
[97]  D. Thurman and P. Poinsatte, “Experimental heat transfer and bulk air temperature measurements for a multipass internal cooling model with ribs and bleed,” ASME Paper 2000-GT-233, 2000.
[98]  D. G. N. Tse and G. D. Steubner, “Flow in a rotating square serpentine coolant passage with skewed trips,” ASME Paper 97-GT-529, 1997.
[99]  K. Watanabe and T. Takahashi, “LES simulation and experimental measurement of fully developed ribbed channel flow and heat transfer,” ASME Paper GT-2002-30203, 2002.
[100]  Y. M. Zhang, J. C. Han, J. A. Parsons, and C. P. Lee, “Surface heating effect on local heat transfer in a rotating two-pass square channel with 60 deg angled rib turbulators,” Journal of Turbomachinery, vol. 117, no. 2, pp. 272–280, 1995, ASME Paper 93-GT-336.
[101]  C. C. Chen and T. M. Liou, “Rotating effect on fluid flow in a smooth duct with a 180-deg sharp turn,” ASME Paper 2000-GT-0228, 2000.
[102]  F. Zhou and S. Acharya, “Heat transfer at high rotation numbers in a two-pass 4:1 aspect ratio rectangular channel with 45 deg skewed ribs,” Journal of Turbomachinery, vol. 130, no. 2, Article ID 021019, 2008.
[103]  J. H. Wagner, B. V. Johnson, and T. J. Hajek, “Heat transfer in rotating passages with smooth walls and radial outward flow,” Journal of Turbomachinery, vol. 113, no. 1, pp. 42–51, 1991, ASME Paper 89-GT-272.
[104]  M. Huh, J. Lei, Y. H. Liu, and J. C. Han, “High rotation number effects on heat transfer in a rectangular (AR=2:1) two pass channel,” ASME Paper GT2009-59421, 2009.
[105]  A. Ogawa, Vortex Flow, CRC Press, New York, NY, USA, 1993.
[106]  B. Glezer, H.-K. Moon, and T. O'Connell, “A novel technoique for the internal blade cooling,” ASME Paper 96-GT-181, 1996.
[107]  B. Glezer, H.-K. Moon, J. Kerrebrock, J. Bons, and G. Guenette, “Heat transfer in a rotating radial channel with swirling internal flow,” ASME Paper 98-GT-214, 1998.
[108]  A. E. Bergles, “Survey and evaluation of techniques to augment convective heat and mass transfer,” International Journal of Heat and Mass Transfer, vol. 1, pp. 331–413, 1969.
[109]  H. H. Bruun, A. Fitouri, and M. K. Khan, “Use of a multiposition single yawed hot-wire probe for measurements in swirling flow,” in Proceedings of the Fluids Engineering Conference, vol. 167, pp. 57–65, June 1993.
[110]  F. Chang and V. K. Dhir, “Turbulent flow field in tangentially injected swirl flows in tubes,” International Journal of Heat and Fluid Flow, vol. 15, no. 5, pp. 346–356, 1994.
[111]  A. W. Date, “Prediction of fully-developed flow in a tube containing a twisted-tape,” International Journal of Heat and Mass Transfer, vol. 17, no. 8, pp. 845–859, 1974.
[112]  M. Dong and D. G. Lilley, “Parameter effects on flow patterns in confined turbulent swirling flows,” in Proceedings of the International Joint Power Generation Conference, vol. 17, October 1993.
[113]  A. Fitouri, M. K. Khan, and H. H. Bruun, “A multiposition hot-wire technique for the study of swirling flows in vortex chambers,” Experimental Thermal and Fluid Science, vol. 10, no. 1, pp. 142–151, 1995.
[114]  W. R. Gambill and R. D. Bundy, “An evaluation of the present status of swirl-flow heat transfer,” ASME Paper 62-HT-42, 1962.
[115]  C. R. Hedlund and P. M. Ligrani, “Local swirl chamber heat transfer and flow structure at different Reynolds numbers,” Journal of Turbomachinery, vol. 122, no. 2, pp. 375–385, 2000.
[116]  C. R. Hedlund, P. M. Ligrani, H. K. Moon, and B. Glezer, “Heat transfer and flow phenomena in a swirl chamber simulating turbine blade internal cooling,” Journal of Turbomachinery, vol. 121, no. 4, pp. 804–813, 1999.
[117]  S. W. Hong and A. E. Bergles, “Augmentation of laminar flow heat transfer in tubes by means of twisted-tape inserts,” Journal of Heat Transfer, vol. 98, no. 2, pp. 251–256, 1976.
[118]  J. J. Hwang and C. S. Cheng, “Augmented heat transfer in a triangular duct by using multiple swirling jets,” Journal of Heat Transfer, vol. 121, no. 3, pp. 683–690, 1999.
[119]  J. B. W. Kok, F. J. J. Rosendal, and J. J. H. Brouwers, “LDA-measurements on swirling flows in tubes,” in Proceedings of the 5th International Conference on Laser Anemometry, vol. 2052 of Proceedings of SPIE, pp. 721–728, August 1993.
[120]  F. Kreith and D. Margolis, “Heat transfer and friction in turbulent vortex flow,” Applied Scientific Research, vol. 8, no. 1, pp. 457–473, 1959.
[121]  R. Kumar and T. Conover, “Flow visualization studies of a swirling flow in a cylinder,” Experimental Thermal and Fluid Science, vol. 7, no. 3, pp. 254–262, 1993.
[122]  H. Li and Y. Tomita, “Characteristics of swirling flow in a circular pipe,” Journal of Fluids Engineering, vol. 116, no. 2, pp. 370–373, 1994.
[123]  P. M. Ligrani, C. R. Hedlund, B. T. Babinchak, R. Thambu, H. K. Moon, and B. Glezer, “Flow phenomena in swirl chambers,” Experiments in Fluids, vol. 24, no. 3, pp. 254–264, 1998.
[124]  H.-K. Moon, T. O'Connell, and B. Glezer, “Heat transfer enhancement in a circular channel using lengthwise continuous tangential injection,” in Proceedings of the International Heat Transfer Congress (IHTC '98), Seoul, South Korea, 1998.
[125]  P. Papadopoulos, D. M. France, and W. J. Minkowycz, “Heat transfer to dispersed swirl flow of high-pressure water with low wall superheat,” Experimental Heat Transfer, vol. 4, no. 2, pp. 153–169, 1991.
[126]  R. Razgaitis and J. P. Holman, “A survey of heat transfer in confined swirling flows,” in Future Energy Production Systems, Heat and Mass Transfer Processes, vol. 2, pp. 831–866, Academic Press, New York, NY, USA, 1976.
[127]  W. F. J. Sampers, A. P. G. G. Lamers, and A. A. van Steenhoven, “Experimental and numerical analysis of a turbulent swirling flow in a tube,” in Proceedings of the 3rd UK National Conference incorporating 1st European Conference on Thermal Sciences, vol. 2 of ICHEME Symposium Series no. 129, pp. 765–771, September 1992.
[128]  W. L. Fu, L. M. Wright, and J. C. Han, “Rotational buoyancy effects on heat transfer in five different aspect-ratio rectangular channels with smooth walls and 45 degree ribbed walls,” Journal of Heat Transfer, vol. 128, no. 11, pp. 1130–1141, 2006, ASME Paper GT 2005-68493.
[129]  B. J. Belnap, J. A. Van Rij, and P. M. Ligrani, “A Reynolds analogy for real component surface roughness,” International Journal of Heat and Mass Transfer, vol. 45, no. 15, pp. 3089–3099, 2002.
[130]  J. A. Van Rij, B. J. Belnap, and P. M. Ligrani, “Analysis and experiments on three-dimensional, irregular surface roughness,” Journal of Fluids Engineering, Transactions of the ASME, vol. 124, no. 3, pp. 671–677, 2002.
[131]  D. L. Gee and R. L. Webb, “Forced convection heat transfer in helically Rib-roughened tubes,” International Journal of Heat and Mass Transfer, vol. 23, no. 8, pp. 1127–1136, 1980.
[132]  X. Chi, T. I.-P. Shihb, K. M. Bryden et al., “Effects of pin-fin height on flow and heat transfer in a rectangular duct,” ASME Paper GT2011-46014, 2011.
[133]  J. K. Ostanek and K. A. Thole, “Flow field measurements in a single row of low aspect ratio pin-fins,” ASME Paper GT2011-45757, 2011.
[134]  J. K. Ostanek and K. A. Thole, “Effects of varying steamwise and spanwise spacing in pin-fin arrays,” ASME Paper GT2012-68127, 2012.
[135]  X. Wang, X. Bai, J. Wu, R. Liu, D. Zhu, and G. Liao, “Numerical study on heat transfer characteristics in rectangular ducts with pin-fins,” ASME Paper GT2011-45286, 2011.
[136]  Y. Rao, C. Wan, and S. Zang, “Comparisons of flow friction and heat transfer performance in rectangular channels with pin fin-dimple arrays,” ASME Paper GT2010-22442, 2010.
[137]  C. Bianchini, B. Facchini, S. Zacchi, F. Simonetti, and L. Tachi, “Numerical and experimental investigation of turning flow effects of innovative pin fin arrangements for trailing edge cooling configurations,” ASME Paper GT2010-23536, 2010.
[138]  M. L. Busche, L. P. Moualeu, N. Chowdhury, C. Tang, and F. E. Ames, “Heat transfer and pressure drop measurements in high solidity pin fin cooling arrays with incremental replenishment,” ASME Paper GT2012-69289, 2012.
[139]  J. B. Cowan, D. K. Tafti, and A. Kohli, “Investigation of sand particle deposition and erosion characteristics within a short pin fin array,” ASME Paper GT2010-22362, 2010.
[140]  S. C. Siw, M. K. Chyu, T. I.-P. Shih, and M. A. Alvin, “Effects of pin detached space on heat transfer and from pin fin arrays,” ASME Paper GT2010-23227, 2010.
[141]  L. V. Tran, M. I. Valentino, A. Saha et al., “PIV study on the dimple mid-plane of a narrow rectangular channel with dimples applied to one wall,” ASME Paper GT2011-46132, 2011.
[142]  C. N. Jordan and L. M. Wright, “Heat transfer enhancement in a rectangular (AR=3:1) channel with V-shaped dimples,” ASME Paper GT2011-46128, 2011.
[143]  R. Amano, K. Guntur, J. M. Lucci, and Y. Ashitaka, “Study of flow through a stationary ribbed channel for blade cooling,” ASME Paper GT2010-23031, 2010.
[144]  J. E. Dees, G. A. Ledezma, A. K. Tolpadi, G. M. Lashowski, and D. G. Bogard, “Experimental measurements and computational predictions for an internally cooled simulated turbine vane with 90 degree Rib turbulators,” ASME Paper GT2010-23004, 2010.
[145]  T. Hagari, K. Ishida, K.-I. Takeishi, Y. Oda, and H. Kitada, “Investigation on heat transfer characteristics of a cooling channel With dense array of angled Rib turbulator,” ASME Paper GT2012-68949, 2012.
[146]  C. LeBlanc, S. V. Ekkad, T. Lambert, and V. Rajendran, “Detailed heat transfer distributions in engine similar cooling channels for a turbine rotor blade with different Rib orientations,” ASME Paper GT2011-45254, 2011.
[147]  G. Ledezma and R. Bunker, “The optimal distribution of chordwise Rib Fin arrays for blade Tip Cap underside cooling,” ASME Paper GT2012-68432, 2012.
[148]  J. Lei, M. Huh, and J.-C. Han, “Effect of rib spacing on heat transfer in a two pass rectangular channel (AR=2:1) at high rotation numbers,” ASME Paper GT2011-45926, 2011.
[149]  J. Lei, S.-J. Li, J.-C. Han, L. Zhang, and H.-K. Moon, “Heat transfer in rotating multi-pass rectangular ribbed channel with and without a turning vane,” ASME Paper GT2012-69139, 2012.
[150]  S. Patil and D. Tafti, “Large-eddy simulation with zonal near wall treatment of flow and heat transfer in a ribbed duct for the internal cooling of turbine blades,” ASME Paper GT2011-45749, 2011.
[151]  B. V. N. Ramakumar, V. R. Kollati, S. Goswami, V. Kulkarni, J. S. Liu, and D. C. Crites, “Numerical validation of heat transfer augmentation factor in serpentine passages with ribbed walls,” ASME Paper GT2010-22636, 2010.
[152]  K. Saha and S. Acharya, “Effect of entrance geometry on heat transfer in a narrow (AR=1:4) rectangular two pass channel with smooth and ribbed walls,” ASME Paper GT2011-46076, 2011.
[153]  T. Salameh and B. Sunden, “Effects of ribs on internal blade-tip cooling,” ASME Paper GT2011-45118, 2011.
[154]  H. Zhang, J. Wang, X. Wu, and H. Lu, “A simplified approach to design transverse ribs which array alternately in rectangular channel,” ASME Paper, no. GT2010-22562, 2010.
[155]  T. Salameh and B. Sunden, “Comparison of continuous and truncated ribs on internal blade tip cooling,” ASME Paper GT2012-68028, 2012.
[156]  G. Xie, S. Li, W. Zhang, and B. Sundén, “Computational analysis of side-wall heat transfer of a turbine blade internal cooling passage with truncated ribs on opposite walls,” ASME Paper GT2012-68073, 2012.
[157]  J. Wang, H. Liu, M. Mao, X. Li, and Z. Zhang, “Numerical investigations of fluid flow and heat transfer performances of semiattached rib channel design,” ASME Paper GT2010-22563, 2010.
[158]  D. M. Lee, J. S. Park, D. H. Lee, B. S. Kim, and H. H. Cho, “Heat transfer characteristics of a non-rotating two-pass rectangular duct with various guide vanes in the tip turn region,” ASME Paper GT2011-45962, 2011.
[159]  B. Cukurel, C. Selcan, and T. Arts, “Film cooling extraction effects on the aero-thermal characteristics of rib roughened cooling channel flow,” ASME Paper GT2012-68680, 2012.
[160]  T. Guo, H. Zhu, and D. Xu, “Heat transfer investigation of the channels with Rib turbulators and double-row bleed holes,” ASME Paper GT2011-46319, 2011.
[161]  Y. Xing and B. Weigand, “Experimental investigation on staggered impingement heat transfer on a rib roughened plate with different crossflow schemes,” ASME Paper GT2010-22043, 2010.
[162]  F. Coletti, M. Scialanga, and T. Arts, “Experiemental investigation of conjugate heat transfer in a rib-roughened trailing edge channel with crossing-jets,” ASME Paper GT2010-22432, 2010.
[163]  F. Hoefler, S. Schueren, J. von Wolfersdorf, and S. Naik, “Heat transfer characteristics of an oblique jet impingement configuration in a passage with ribbed surfaces,” ASME Paper GT2010-22288, 2010.
[164]  Q. Yang, Y. Lin, C. Zhang, C.-J. Sung, and Q. Xu, “Cooling effectiveness of impingement/effusion cooling with and turbulence promoter ribs,” ASME Paper GT2012-69209, 2012.
[165]  J. Liu, J. Gao, and T. Gao, “An experimental investigation of heat transfer characteristics in a steam-cooled square channel with rib turbulators,” ASME Paper GT2011-46134, 2011.
[166]  L. Shui, J. Gao, L. Xu, and X. Wang, “Numerical investigation of heat transfer and flow characteristics in a steam-cooled square ribbed duct,” ASME Paper GT2010-22407, 2010.
[167]  T. S. Dhanasekaran and T. Wang, “Mist/air cooling in a two-pass rectangular rotating channel with 45-deg angled Rib turbulators,” ASME Paper GT2011-45954, 2011.
[168]  R. S. Amano, K. S. Guntur, J. Martinez-Lucci, and S. Kumar, “Numerical comparison of heat transfer and pressure drop in gas turbine blade cooling channels with dimples and rib-turbulators,” ASME Paper GT2011-45277, 2011.
[169]  L. Qui, H. Deng, and Z. Tao, “Effect of channel orientation in a rotating wedge-shaped cooling channel with pin fins and ribs,” ASME Paper GT2012-68439, 2012.
[170]  J. Lan, Y. Xie, and D. Zhang, “Heat transfer enhancement in a rectangular channel with the combination of ribs, dimples and protrusions,” ASME Paper GT2011-46031, 2011.
[171]  Z. Feng, Z. Dou, J. Wang, S. Ma, and Z. Zhang, “Numerical investigations of cooling enhancement with internal ribs and external coolant film,” ASME Paper GT2012-68682, 2012.
[172]  L. Wang, B. Sunden, A. Borg, and H. Abrahamsson, “Heat transfer in a channel under the effects of a shallow-angle jet impingement and a rib,” ASME Paper GT2011-46333, 2011.
[173]  S. Acharya, F. Zhou, J. Lagrone, G. Mahmood, and R. S. Bunker, “Latticework (Vortex) cooling effectiveness: rotating channel experiments,” Journal of Turbomachinery, vol. 127, no. 3, pp. 471–478, 2005, ASME Paper 2004-GT-53983.
[174]  K. Takeishi, Y. Oda, Y. Miyake, and Y. Motoda, “Experimental and numerical study on the convective heat transfer and pressure loss in rectangular ducts with inclined pin-fins on a wavy endwall,” ASME Paper 2012-69625, 2012.
[175]  Y. Motoda, K. Takeishi, Y. Oda, and Y. Miyake, “A study of the effect of angled pin fins on endwall heat transfer,” in Proceedings of the International Conference on Power Engineering (ICOPE '09), Kobe, Japan, 2009.
[176]  R. S. Bunker, J. C. Bailey, C.-P. Lee, and C. W. Stevens, “In-wall netweork (Mesh) cooling augmentation of gas turbine airfoils,” ASME Paper 2004-54260, 2004.
[177]  Y. Servouze and J. C. Sturgis, “Heat transfer and flow field measurements in a rib-roughened branch of a rotating two-pass duct,” ASME Paper GT2003-38048, 2003.
[178]  J. P. Bons and J. L. Kerrebrock, “Complementary velocity and heat transfer measurements in a rotating cooling passage with smooth walls,” Journal of Turbomachinery, vol. 121, no. 4, pp. 651–662, 1999, ASME Paper 98-GT-464.
[179]  L. M. Wright, W. L. Fu, and J. C. Han, “Influence of entrance geometry on heat transfer in rotating rectangular cooling channels (AR=4:1) with angled ribs,” Journal of Heat Transfer, vol. 127, no. 4, pp. 378–387, 2005.
[180]  S. Acharya, D. E. Nikitopoulos, and P. Agarwal, “Heat/mass transfer in a 4:1 AR smooth and ribbed coolant passage with rotation in 90-degree and 45-degree orientations,” ASME Paper GT2004-53928, 2004.
[181]  D. H. Lee, D. H. Rhee, and H. H. Cho, “Heat transfer measurements in a rotating equilateral triangular channel with various rib arrangements,” ASME Paper GT2006-90973, 2006.
[182]  Y. H. Liu, L. M. Wright, W. L. Fu, and J. C. Han, “Rib spacing effect on heat transfer and pressure loss in a rotating two-pass rectangular channel (AR=1:2) with 45-degree angled ribs,” AIAA Journal of Thermophysics and Heat Transfer, vol. 21, no. 3, pp. 582–595, 2006, ASME Paper GT2006-90368.
[183]  L. Al-Hadhrami, T. Griffith, and J. C. Han, “Heat transfer in two-pass rotating rectangular channels (AR=2) with five different orientations of 45 deg v-shaped rib turbulators,” Journal of Heat Transfer, vol. 125, no. 2, pp. 232–242, 2003, AIAA Paper 2002-0789.
[184]  L. Al-Hadhrami and J. C. Han, “Effect of rotation on heat transfer in two-pass square channels with five different orientations of 45° angled rib turbulators,” International Journal of Heat and Mass Transfer, vol. 46, no. 4, pp. 653–669, 2003.
[185]  H. D. Chiang and H. L. Li, “Jet impingement and forced convection cooling experimental study in rotating turbine blades,” ASME Paper GT2009-59795, 2009.
[186]  W. L. Fu, L. M. Wright, and J. C. Han, “Heat transfer in two-pass rotating rectangular channels (AR = 1:2 and AR = 1:4) with 45° angled Rib turbulators,” Journal of Turbomachinery, vol. 127, no. 1, pp. 164–174, 2004, ASME Paper GT2004-53261.
[187]  W. L. Fu, L. M. Wright, and J. C. Han, “Heat transfer in two-pass rotating rectangular channels (AR=1:2 and AR=1:4) with smooth walls,” Journal of Heat Transfer, vol. 127, no. 3, pp. 265–277, 2005.
[188]  T. J. Hajek and A. W. Higgins, “Coolant passage heat transfer with rotation,” NASA N88-11160, Lewis Research Center, Turbine Engine Hot Section Technology, 1985.
[189]  T. J. Hajek, J. H. Wagner, and B. V. Johnson, “Coolant passage heat transfer with rotation,” NASA N89-17314, Lewis Research Center, Turbine Engine Hot Section Technology, 1986.
[190]  J. C. Han, Y. M. Zhang, and K. Kalkuehler, “Uneven wall temperature effect on local heat transfer in a rotating two-pass square channel with smooth walls,” Journal of Heat Transfer, vol. 115, no. 4, pp. 912–920, 1993.
[191]  S. S. Hsieh and W. J. Liu, “Uneven wall heat flux effect on local heat transfer in rotating two-pass channels with two opposite ribbed walls,” Journal of Heat Transfer, vol. 118, no. 4, pp. 864–876, 1996.
[192]  S. S. Hsieh, Y. S. Wang, and M. H. Chiang, “Local heat transfer and velocity measurements in a rotating ribbed two-pass square channel with uneven wall temperatures,” Journal of Heat Transfer, vol. 119, no. 4, pp. 843–848, 1997.
[193]  M. Huh, Y. H. Liu, J. C. Han, and S. Chopra, “Effect of rib spacing on heat transfer in a two-pass rectangular channel (AR=1:4) with a sharp entrance at high rotation numbers,” ASME Paper GT2008-50311, 2008.
[194]  G. J. Hwang, S. C. Tzeng, C. P. Mao, and C. Y. Soong, “Heat transfer in a radially rotating four-pass serpentine channel with staggered half-V rib turbulators,” Journal of Heat Transfer, vol. 123, no. 1, pp. 39–50, 2001.
[195]  H. Ito and K. Nanbu, “Flow in rotating straight pipes of circular cross section,” Journal of Basic Engineering, vol. 93, no. 3, pp. 383–394, 1971.
[196]  T. M. Liou and C. C. Chen, “Heat transfer in a rotating two-pass smooth passage with a 180° rectangular turn,” International Journal of Heat and Mass Transfer, vol. 42, no. 2, pp. 231–247, 1998.
[197]  T. M. Liou, C. C. Chen, and M. Y. Chen, “TLCT and LDV measurements of heat transfer and fluid flow in a rotating sharp turning duct,” International Journal of Heat and Mass Transfer, vol. 44, no. 9, pp. 1777–1787, 2001.
[198]  T. M. Liou, M. Y. Chen, and M. H. Tsai, “Fluid flow and heat transfer in a rotating two-pass square duct with in-line 90-deg ribs,” Journal of Turbomachinery, vol. 124, no. 2, pp. 260–268, 2002, ASME Paper 2001-GT-185.
[199]  T. M. Liou, Y. S. Hwang, and M. Y. Chen, “Heat transfer improvement by arranging detached ribs on suction surfaces of rotating internal coolant passages,” International Journal of Heat and Mass Transfer, vol. 50, no. 11-12, pp. 2414–2424, 2007.
[200]  Y. H. Liu, M. Huh, J. C. Han, and S. Chopra, “Heat transfer in a two-pass rectangular channel (AR=1:4) under high rotation numbers,” Journal of Heat Transfer, vol. 130, no. 8, Article ID 081701, 9 pages, 2008, ASME Paper GT2007-27067.
[201]  S. Mochizuki, J. Takamura, S. Yamawaki, and W. J. Yang, “Heat transfer in serpentine flow passages with rotation,” Journal of Turbomachinery, vol. 116, no. 1, pp. 133–140, 1994, ASME Paper 92-GT-190.
[202]  J. H. Wagner, B. V. Johnson, R. A. Graziani, and F. C. Yeh, “Heat transfer in rotating serpentine passages with trips normal to the flow,” NASA TM 103758, 1991.
[203]  J. H. Wagner, B. V. Johnson, R. A. Graziani, and F. C. Yeh, “Heat transfer in rotating serpentine passages with trips normal to the flow,” Journal of Turbomachinery, vol. 114, no. 4, pp. 847–857, 1991.
[204]  J. H. Wagner, B. V. Johnson, and F. C. Kopper, “Heat transfer in rotating serpentine passages with smooth walls,” Journal of Turbomachinery, vol. 113, no. 3, pp. 321–330, 1991, ASME Paper 90-GT-331.
[205]  W. J. Yang, N. Zhang, and J. Chiou, “Local heat transfer in a rotating serpentine flow passage,” Journal of Heat Transfer, vol. 114, no. 2, pp. 354–361, 1992.
[206]  F. Zhou, J. Lagrone, and S. Acharya, “Internal cooling in 4:1 AR passages at high rotation numbers,” Journal of Heat Transfer, vol. 129, no. 12, pp. 1666–1675, 2007.
[207]  G. J. Hwang, S. C. Tzeng, and C. P. Mao, “Heat transfer of compressed air flow in a spanwise rotating four-pass serpentine channel,” Journal of Heat Transfer, vol. 121, no. 3, pp. 583–591, 1999.
[208]  T. S. Griffith, L. Al-Hadhrami, and J. C. Han, “Heat transfer in rotating rectangular cooling channels (AR=4) with angled ribs,” Journal of Heat Transfer, vol. 124, no. 4, pp. 617–625, 2002.
[209]  T. S. Griffith, L. Al-Hadhrami, and J. C. Han, “Heat transfer in rotating rectangular cooling channels (AR = 4) with dimples,” Journal of Turbomachinery, vol. 125, no. 3, pp. 555–563, 2003, ASME Paper 2002-GT-30220.
[210]  J. C. Han and Y. M. Zhang, “Effect of uneven wall temperature on local heat transfer in a rotating square channel with smooth walls and radial outward flow,” Journal of Heat Transfer, vol. 114, no. 4, pp. 850–858, 1992.
[211]  J. C. Han, Y. M. Zhang, and C. P. Lee, “Influence of surface heating condition on local heat transfer in a rotating square channel with smooth walls and radial outward flow,” Journal of Turbomachinery, vol. 116, no. 1, pp. 149–158, 1994, ASME Paper 92-GT-188.
[212]  E. Lee, L. M. Wright, and J. C. Han, “Heat transfer in rotating rectangular channels (AR=4:1) with V-shaped and angled rib turbulators with and without gaps,” ASME Paper GT2003-38900, 2003.
[213]  L. M. Wright, E. Lee, and J. C. Han, “Effect of rotation on heat transfer in rectangular channels with pin fins,” Journal of Thermophysics and Heat Transfer, vol. 18, no. 2, pp. 263–272, 2004.
[214]  N. Zhang, J. Chiou, S. Fann, and W. J. Yang, “Local heat transfer distribution in a rotating serpentine rib-roughened flow passage,” Journal of Heat Transfer, vol. 115, no. 3, pp. 560–567, 1993.
[215]  G. J. Hwang and C. R. Kuo, “Experimental studies and correlations of convective heat transfer in a radially rotating serpentine passage,” Journal of Heat Transfer, vol. 119, no. 3, pp. 460–466, 1997.
[216]  K. M. Kim, Y. Y. Kim, D. H. Lee, D. H. Rhee, and H. H. Cho, “Influence of duct aspect ratio on heat/mass transfer in coolant passages with rotation,” International Journal of Heat and Fluid Flow, vol. 28, no. 3, pp. 357–373, 2007.
[217]  C. R. Kuo and G. J. Hwang, “Experimental studies and correlations of radially outward and inward air-flow heat transfer in a rotating square duct,” Journal of Heat Transfer, vol. 118, no. 1, pp. 23–30, 1996.
[218]  C. R. Kuo and G. J. Hwang, “Aspect ratio effect on convective heat transfer of radially outward flow in rotating rectangular ducts,” International Journal of Rotating Machinery, vol. 1, no. 1, pp. 1–18, 1994.
[219]  L. M. Wright, W. L. Fu, and J. C. Han, “Thermal performance of angled, V-shaped, and W-shaped rib turbulators in rotating rectangular cooling channels (AR=4:1),” Journal of Turbomachinery, vol. 126, no. 4, pp. 604–614, 2004, ASME Paper 2004-GT-54073.
[220]  S. W. Chang and W. D. Morris, “Heat transfer in a radially rotating square duct fitted with in-line transverse ribs,” International Journal of Thermal Sciences, vol. 42, no. 3, pp. 267–282, 2003.
[221]  S. W. Chang, T. L. Yang, T. M. Liou, and G. F. Hong, “Heat transfer of rotating rectangular duct with compound scaled roughness and V-ribs at high rotation numbers,” International Journal of Thermal Sciences, vol. 48, no. 1, pp. 174–187, 2009.
[222]  S. W. Chang, T. L. Yang, T. M. Liou, and H. G. Fang, “Heat transfer in rotating scale-roughened trapezoidal duct at high rotation numbers,” Applied Thermal Engineering, vol. 29, no. 8-9, pp. 1682–1693, 2009.
[223]  S. Dutta, J. C. Han, Y. Zhang, and C. P. Lee, “Local heat transfer in a rotating two-pass triangular duct with smooth walls,” Journal of Turbomachinery, vol. 118, no. 3, pp. 435–443, 1996, ASME Paper 94-GT-337.
[224]  S. P. Harasgama and W. D. Morris, “The influence of rotation on the heat transfer characteristics of circular, triangular, and square-sectioned coolant passages of gas turbine rotor blades,” Journal of Turbomachinery, vol. 110, no. 1, pp. 44–50, 1988.
[225]  S. S. Hsieh and Y. J. Hong, “Heat transfer coefficients in an orthogonally rotating duct with turbulators,” Journal of Heat Transfer, vol. 117, no. 1, pp. 69–78, 1995.
[226]  W. D. Morris and T. Ayhan, “Observations on the influence of rotation on heat transfer in the coolant channels of gas turbine rotor blades,” Proceedings of the Institution of Mechanical Engineers, vol. 193, pp. 303–311, 1979.
[227]  W. D. Morris and S. W. Chang, “An experimental study of heat transfer in a simulated turbine blade cooling passage,” International Journal of Heat and Mass Transfer, vol. 40, no. 15, pp. 3703–3716, 1997.
[228]  W. D. Morris and R. Salemi, “An attempt to uncouple the effect of Coriolis and buoyancy forces experimentally on heat transfer in smooth circular tubes that rotate in the orthogonal mode,” Journal of Turbomachinery, vol. 114, no. 4, pp. 858–864, 1992, ASME Paper 91-GT-17.
[229]  A. Murata, S. Mochizuki, and T. Takahashi, “Local heat transfer measurements of an orthogonally rotating square duct with angled rib turbulators,” International Journal of Heat and Mass Transfer, vol. 42, no. 16, pp. 3047–3056, 1999.
[230]  L. M. Wright, Y. H. Liu, J. C. Han, and S. Chopra, “Heat transfer in trailing edge, wedge-shaped cooling channels under high rotation numbers,” Journal of Heat Transfer, vol. 130, no. 7, Article ID 071701, 11 pages, 2007, ASME Paper GT2007-27093.
[231]  S. W. Chang, T. M. Liou, J. H. Hung, and W. H. Yeh, “Heat transfer in a radially rotating square-sectioned duct with two opposite walls roughened by 45 deg staggered ribs at high rotation numbers,” Journal of Heat Transfer, vol. 129, no. 2, pp. 188–199, 2007.
[232]  S. Dutta, J. C. Han, and C. P. Lee, “Experimental heat transfer in a rotating triangular duct: effect of model orientation,” Journal of Heat Transfer, vol. 117, no. 4, pp. 1058–1061, 1995.
[233]  T. M. Liou, S. W. Chang, J. H. Hung, and S. F. Chiou, “High rotation number heat transfer of a 45° rib-roughened rectangular duct with two channel orientations,” International Journal of Heat and Mass Transfer, vol. 50, no. 19-20, pp. 4063–4078, 2007.
[234]  W. D. Morris and K. F. Rahmat-Abadi, “Convective heat transfer in rotating ribbed tubes,” International Journal of Heat and Mass Transfer, vol. 39, no. 11, pp. 2253–2266, 1996.
[235]  F. T. Willett and A. E. Bergles, “Heat transfer in rotating narrow rectangular pin-fin ducts,” Experimental Thermal and Fluid Science, vol. 25, no. 7, pp. 573–582, 2002.
[236]  S. W. Chang, T. L. Yang, and W. J. Wang, “Heat transfer in a rotating twin-pass trapezoidal-sectioned passage roughened by skewed ribs on two opposite walls,” Heat Transfer Engineering, vol. 27, no. 10, pp. 63–79, 2006.
[237]  W. D. Morris and G. Ghavami-Nasr, “Heat transfer measurements in rectangular channels with orthogonal mode rotation,” Journal of Turbomachinery, vol. 113, no. 3, pp. 339–345, 1991, ASME Paper 90-GT-138.
[238]  S. Acharya, V. Eliades, and D. E. Nikitopoulos, “Heat transfer enhancements in rotating two-pass coolant channels with profiled ribs: part 1-average results,” Journal of Turbomachinery, vol. 123, no. 1, pp. 97–106, 2001, ASME Paper 2000-GT-227.
[239]  P. Agarwal, S. Acharya, and D. E. Nikitopoulos, “Heat transfer in 1:4 rectangular passages with rotation,” Journal of Turbomachinery, vol. 125, no. 4, pp. 726–733, 2003.
[240]  H. H. Cho, Y. Y. Kim, K. Kim, and D. H. Rhee, “Effects of rib arrangements and rotation speed on heat transfer in a two-pass duct,” ASME Paper GT-2003-38609, 2003.
[241]  H. H. Cho, S. Y. Lee, and D. H. Rhee, “Effects of cross ribs on heat/mass transfer in a two-pass rotating duct,” Heat and Mass Transfer, vol. 40, no. 10, pp. 743–755, 2004.
[242]  H. H. Cho, S. Y. Lee, J. H. Won, and D. H. Rhee, “Heat/mass transfer in a two-pass rotating rectangular duct with and without 70°-angled ribs,” Heat and Mass Transfer, vol. 40, no. 6-7, pp. 467–475, 2004.
[243]  K. M. Kim, D. H. Lee, and H. H. Cho, “Detailed measurement of heat/mass transfer and pressure drop in a rotating two-pass duct with transverse ribs,” Heat and Mass Transfer, vol. 43, no. 8, pp. 801–815, 2007.
[244]  C. W. Park and S. C. Lau, “Effect of channel orientation of local heat (mass) transfer distributions in a rotating two-pass square channel with smooth walls,” Journal of Heat Transfer, vol. 120, no. 3, pp. 624–632, 1998.
[245]  C. W. Park, S. C. Lau, and R. T. Kukreja, “Heat (mass) transfer in a rotating channel with ribs of various sizes on two walls,” Journal of Thermophysics and Heat Transfer, vol. 12, no. 3, pp. 452–454, 1998.
[246]  C. W. Park, S. C. Lau, and R. T. Kukreja, “Heat/mass transfer in a rotating two-pass channel with transverse ribs,” Journal of Thermophysics and Heat Transfer, vol. 12, no. 1, pp. 80–86, 1998.
[247]  C. W. Park, C. Yoon, and S. C. Lau, “Heat (mass) transfer in a diagonally oriented rotating two-pass channel with rib-roughened walls,” Journal of Heat Transfer, vol. 122, no. 1, pp. 208–211, 2000.
[248]  S. W. Chang, T.-M. Liou, and T.-H. Lee, “Detailed heat transfer distributions and pressure drop measurements for a rotating parallelogram channel with radially outward flow,” ASME Paper GT2011-45456, 2011.
[249]  S.-Y. Hu, T. I.-P. Shih, M. K. Chyu et al., “Flow and heat transfer in the tip-turn region of a U-duct under rotating and non-rotating conditions,” ASME Paper GT2011-46013, 2011.
[250]  M. Huh, J. Lei, and J.-C. Han, “Influence of channel orientation on heat transfer in a two-pass smooth and ribbed rectangular channel (AR=2:1) under large rotation numbers,” ASME Paper GT2010-22190, 2010.
[251]  A. P. Rallabandi, Y.-H. Liu, and J.-C. Han, “Heat transfer in trailing edge wedge-shaped pin-fin channels with slot ejection under high rotation numbers,” ASME Paper GT2010-22832, 2010.
[252]  S. W. Chang, T.-M. Liou, and T.-H. Lee, “Heat transfer of rotating rectangular channel with diamond shaped pin-fin array at high rotation numbers,” ASME Paper GT2012-68676, 2012.
[253]  J. A. Lamont and S. V. Ekkad, “Effects of rotation on jet impingement channel heat transfer,” ASME Paper GT2011-45744, 2011.
[254]  M. A. Elyyan and D. K. Tafti, “Investigation of coriolis forces effect of flow structure and heat transfer distribution in a rotating dimpled channel,” ASME Paper GT2010-22657, 2010.
[255]  S. W. Chang, T.-M. Liou, and W. C. Chen, “Heat transfer in a rotating rectangular channel with two opposite walls roughened with spherical protrusions at high rotation numbers,” ASME Paper GT2010-22609, 2010.
[256]  L. Bonanni, C. Carcasci, B. Facchini, and L. Tarchi, “Experiemental survey on heat transfer in a trailing edge cooling system: effects of rotation in internal cooling ducts,” ASME Paper GT2012-69638, 2012.
[257]  D. Borello, G. Delibra, C. Bianchini, and A. Andreini, “Unsteady CFD analysis of turbulent flow and heat transfer in a gas turbine blade trailing edge subjected to rotation,” ASME Paper GT2012-69903, 2012.
[258]  M. Pascotto, A. Armellini, L. Casarsa, P. Giannattasio, and C. Mucignat, “Effects of rotation and channel orientation on the flow field inside a trailing edge internal cooling channel,” ASME Paper GT2012-68050, 2012.
[259]  M. Schroll, M. Elfert, and L. Lange, “Investigation of the effect of rotation on the flow in a two-pass cooling system with smooth and ribbed walls using PIV,” ASME Paper GT2011-46427, 2011.
[260]  M. Schüler, Dreher, H. -M, M. Elfert, S. O. Neumann, and B. Weigand, “Numerical predictions of the effect of rotation on fluid flow and heat transfer in an engine-similar two-pass internal cooling channel with smooth and ribbed walls,” ASME Paper GT2010-22870, 2010.
[261]  H. A. El-Husayni, M. E. Taslim, and D. M. Kercher, “Experimental heat transfer investigation of stationary and orthogonally rotating asymmetric and symmetric heated smooth and turbulated channels,” Journal of Turbomachinery, vol. 116, no. 1, pp. 124–132, 1994, ASME Paper 92-GT-189.
[262]  J. Guidez, “Study of the convective heat transfer in a rotating coolant channel,” Journal of Turbomachinery, vol. 111, no. 1, pp. 43–50, 1989.
[263]  T. J. Hajek, J. H. Wagner, and B. V. Johnson, “Coolant passage heat transfer with rotation,” NASA, Lewis Research Center, Turbine Engine Hot Section Technology, 1987.
[264]  E. Sethuraman, S. Acharya, and D. E. Nikitopoulos, “Mass/heat transfer in rotating, smooth, high-aspect ratio (4:1) coolant channels with curved walls,” Journal of Turbomachinery, vol. 131, no. 2, Article ID 021002, 9 pages, 2009.
[265]  F. T. Willett and A. E. Bergles, “Heat transfer in rotating narrow rectangular ducts with heated sides parallel to the r-z plane,” Journal of Heat Transfer, vol. 124, no. 1, pp. 1–7, 2002.
[266]  F. T. Willett and A. E. Bergles, “Heat transfer in rotating narrow rectangular ducts with heated sides oriented at 60° to the r-z plane,” Journal of Turbomachinery, vol. 123, no. 2, pp. 288–295, 2001, ASME Paper 2000-GT-224.
[267]  R. J. Clifford, W. D. Morris, and S. P. Harasgama, “An experimental study of local and mean heat transfer in a triangular-sectioned duct rotating in the orthogonal mode,” Journal of Engineering for Gas Turbines and Power, vol. 106, no. 3, pp. 661–667, 1984.
[268]  Y. H. Liu, M. Huh, J. C. Han, and H. K. Moon, “High rotation number effects on heat transfer in a triangular channel with 45°, inverted 45°, and 90° ribs,” ASME Paper GT2009-59216, 2009.
[269]  Y. H. Liu, M. Huh, D. H. Rhee, J. C. Han, and H. K. Moon, “Heat transfer in leading edge, triangular shaped cooling channels with angled ribs under high rotation numbers,” Journal of Turbomachinery, vol. 131, no. 4, Article ID 041017, 12 pages, 2009, ASME Paper GT2008-50344.
[270]  Y. Mori, T. Fukada, and W. Nakayama, “Convective heat transfer in a rotating radial circular pipe (2nd report),” International Journal of Heat and Mass Transfer, vol. 14, no. 11, pp. 1807–1824, 1971.
[271]  T. M. Liou, C. C. Chen, and M. Y. Chen, “Rotating effect on fluid flow in two smooth ducts Connected by a 180-degree bend,” ASME Journal of Fluids Engineering, vol. 125, no. 1, pp. 138–148, 2003.

Full-Text