Corneal Sublayers Thickness Estimation Obtained by High-Resolution FD-OCT

DOI: 10.1155/2013/989624

Full-Text   Cite this paper   Add to My Lib

Abstract:

This paper presents a novel processing technique which can be applied to corneal in vivo images obtained with optical coherence tomograms across the central meridian of the cornea. The method allows to estimate the thickness of the corneal sublayers (Epithelium, Bowman’s layer, Stroma, Endothelium, and whole corneal thickness) at any location, including the center and the midperiphery, on both nasal and temporal sides. The analysis is carried out on both the pixel and subpixel scales to reduce the uncertainty in thickness estimations. This technique allows quick and noninvasive assessment of patients. As an example of application and validation, we present the results obtained from the analysis of 52?healthy subjects, each with 3?scans per eye, for a total of more than 300?images. Particular attention has been paid to the statistical interpretation of the obtained results to find a representative assessment of each sublayer’s thickness. 1. Introduction Optical coherence tomography (OCT) based on low coherence interferometry is a well-established imaging technique thanks to its prominent axial resolution. Since 2006, commercially available OCT systems perform visualization of tissue microstructure in the so-called Fourier Domain (FD-OCT). Differently to Time Domain OCT (TD-OCT), the whole depth structure is obtained synchronously providing higher resolution imaging with faster acquisition times. FD-OCT can be used to provide in vivo cross-sectional imaging of the eye in a noninvasive and noncontact way [1]. To date, this technique has been mostly applied to capture retinal structure and optic nerve, displaying and localizing discrete morphological changes in detail [2, 3]. In this paper we use an FD-OCT to study the anterior segment of the eye since this acquisition system can produce cross-sectional images of the cornea, which can be properly processed to analyze corneal sublayers: Epithelium, Bowman’s layer, Stroma, Descemet’s membrane, and Endothelium [4–7]. The precise measurement of these sublayers thickness is very important in ophthalmics and optometrics, for therapeutic treatments, refractive surgery, and contact lens applications. Many works have presented the thickness estimation of corneal sublayers techniques different from OCT. All these approaches have drawbacks and/or introduce some restrictions. Confocal microscopy [8] is an invasive technique that can cause lesions of corneal tissues, while electron microscopy [8, 9] deals only with histopathologic samples, and ultrasonic pachymetry [10] requires the instillation of a topical anaesthetic

References

[1]  D. Huang, E. A. Swanson, C. P. Lin et al., “Optical coherence tomography,” Science, vol. 254, no. 5035, pp. 1178–1181, 1991.
[2]  W. Drexler and J. G. Fujimoto, “State-of-the-art retinal optical coherence tomography,” Progress in Retinal and Eye Research, vol. 27, no. 1, pp. 45–88, 2008.
[3]  N. A. Nassif, B. Cense, B. H. Park et al., “In vivo high-resolution video-rate spectral-domain optical coherence tomography of the human retina and optic nerve,” Optics Express, vol. 12, no. 3, pp. 367–376, 2004.
[4]  R. N. Khurana, Y. Li, M. Tang, M. M. Lai, and D. Huang, “High-speed optical coherence tomography of corneal opacities,” Ophthalmology, vol. 114, no. 7, pp. 1278–1285, 2007.
[5]  A. Tao, J. Wang, Q. Chen et al., “Topographic thickness of Bowman's layer determined by ultra-high resolution spectral domain-optical coherence tomography,” Investigative Ophthalmology & Visual Science, vol. 52, no. 6, pp. 3901–3907, 2011.
[6]  F. La Rocca, S. J. Chiu, R. P. McNabb, A. N. Kuo, J. A. Izatt, and S. Farsiu, “Robust automatic segmentation of corneal layer boundaries in SDOCT images using graph theory and dynamic programming,” Biomedical Optics Express, vol. 2, no. 6, pp. 1524–1538, 2011.
[7]  J. A. Eichel, A. K. Mishra, D. A. Clausi, P. W. Fieguth, and K. K. Bizheva, “A novel algorithm for extraction of the layers of the cornea,” in Proceedings of Canadian Conference on Computer and Robot Vision (CRV '09), pp. 313–320, May 2009.
[8]  H. F. Li, W. M. Petroll, T. M?ller-Pedersen, J. K. Maurer, H. D. Cavanagh, and J. V. Jester, “Epithelial and corneal thickness measurements by in vivo confocal microscopy through focusing (CMTF),” Current Eye Research, vol. 16, no. 3, pp. 214–221, 1997.
[9]  R. W. Beuerman and L. Pedroza, “Ultrastructure of the human cornea,” Microscopy Research and Technique, vol. 33, pp. 320–335, 1996.
[10]  S. Miglior, E. Albe, M. Guareschi, G. Mandelli, S. Gomarasca, and N. Orzalesi, “Intraobserver and interobserver reproducibility in the evaluation of ultrasonic pachymetry measurements of central corneal thickness,” British Journal of Ophthalmology, vol. 88, no. 2, pp. 174–177, 2004.
[11]  R. C. Gonzalez and R. E. Woods, Digital Image Processing, Prentice-Hall, Upper Saddle River, NJ, USA, 2nd edition, 2002.
[12]  Optovue, http://www.optovue.com/.
[13]  V. Penner and G. Rocha, “Use of the Visante for anterior segment ocular coherence tomography,” Techniques in Ophthalmology, vol. 5, no. 2, pp. 67–77, 2007.
[14]  B. Cense, N. A. Nassif, T. C. Chen et al., “Ultrahigh-resolution high-speed retinal imaging using spectral-domain optical coherence tomography,” Optics Express, vol. 12, no. 11, pp. 2435–2447, 2004.
[15]  “American National Standard for the Safe Use of Lasers,” Tech. Rep. ANSI Z136 1-2007, American National Standard Institute, New York, NY, USA, 2007.
[16]  A. M. Moezzi, S. Sin, and T. L. Simpson, “Novel pachometry calibration,” Optometry and Vision Science, vol. 83, no. 6, pp. E366–E371, 2006.
[17]  PMMA, http://refractiveindex.info/?group=PLASTICS&material=PMMA.
[18]  Mitutoyo, http://www.mitutoyo.com/home.aspx.
[19]  Vogel s.r.l., Brescia, Italia,http://www.vogel.it/.
[20]  J. A. Rice, Mathematical Statistics and Data Analysis, Duxbury Press, Pacific Grove, Calif, USA, 2nd edition, 1994.
[21]  M. A. Shousha, V. L. Perez, J. Wang et al., “Use of ultra-high-resolution optical coherence tomography to detect in vivo characteristics of Descemet's membrane in Fuchs' dystrophy,” Ophthalmology, vol. 117, no. 6, pp. 1220–1227, 2010.
[22]  MATLAB, “The language of technical computing,” http://www.mathworks.com/.
[23]  R. G. Keys, “Cubic convolution interpolation for digital image processing,” IEEE Transactions on Acoustics, Speech, and Signal Processing, vol. 29, no. 6, pp. 1153–1160, 1981.
[24]  Y. Li, M. V. Netto, R. Shekhar, R. R. Krueger, and D. Huang, “A longitudinal study of LASIK flap and stromal thickness with high-speed optical coherence tomography,” Ophthalmology, vol. 114, no. 6, pp. 1124–1132, 2007.
[25]  S. Sin and T. L. Simpson, “The repeatability of corneal and corneal epithelial thickness measurements using optical coherence tomography,” Optometry and Vision Science, vol. 83, no. 6, pp. 360–365, 2006.
[26]  A. Latrive and A. C. Boccara, “In vivo and in situ cellular imaging full-field optical coherence tomography with a rigid endoscopic probe,” Biomedical Optics Express, vol. 2, no. 10, pp. 2897–2904, 2011.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133