Robust Vessel Segmentation in Fundus Images

DOI: 10.1155/2013/154860

Full-Text   Cite this paper   Add to My Lib

Abstract:

One of the most common modalities to examine the human eye is the eye-fundus photograph. The evaluation of fundus photographs is carried out by medical experts during time-consuming visual inspection. Our aim is to accelerate this process using computer aided diagnosis. As a first step, it is necessary to segment structures in the images for tissue differentiation. As the eye is the only organ, where the vasculature can be imaged in an in vivo and noninterventional way without using expensive scanners, the vessel tree is one of the most interesting and important structures to analyze. The quality and resolution of fundus images are rapidly increasing. Thus, segmentation methods need to be adapted to the new challenges of high resolutions. In this paper, we present a method to reduce calculation time, achieve high accuracy, and increase sensitivity compared to the original Frangi method. This method contains approaches to avoid potential problems like specular reflexes of thick vessels. The proposed method is evaluated using the STARE and DRIVE databases and we propose a new high resolution fundus database to compare it to the state-of-the-art algorithms. The results show an average accuracy above 94% and low computational needs. This outperforms state-of-the-art methods. 1. Introduction In ophthalmology the most common way to examine the human eye is to take an eye-fundus photograph and to analyse it. During this kind of eye examinations a medical expert acquires a photo of the eye-background through the pupil with a fundus camera. The analysis of these images is commonly done by visual inspection. This process can require hours in front of a computer screen, in particular in case of medical screening. An example fundus image is shown in Figure 1. Figure 1: An example of eye-fundus image: the macula is shown in the middle, the optic disk is to the right, and the blood vessels are entering and leaving the eye through the optic disk. Our goal is to speed up the diagnosis by processing the images using computer algorithms to find and highlight the most important details. In addition we aim to automatically identify abnormalities and diseases with minimal human interaction. Due to the rapidly increasing spatial resolution of fundus images, the common image processing methods which were developed and tested using low resolution images have shown drawbacks in clinical use. For this purpose, a new generation of methods needs to be developed. These methods need to be able to operate on high resolution images with low computational complexity. In this paper, we

References

[1]  A. F. Frangi, W. J. Niessen, K. L. Vincken, and M. A. Viergever, Multiscale Vessel Enhancement Filtering, Springer, Heidelberg, Germany, 1998.
[2]  C. Kirbas and F. Quek, “A review of vessel extraction techniques and algorithms,” ACM Computing Surveys, vol. 36, no. 2, pp. 81–121, 2004.
[3]  N. Patton, T. M. Aslam, T. MacGillivray et al., “Retinal image analysis: concepts, applications and potential,” Progress in Retinal and Eye Research, vol. 25, no. 1, pp. 99–127, 2006.
[4]  S. Chaudhuri, S. Chatterjee, N. Katz, M. Nelson, and M. Goldbaum, “Detection of blood vessels in retinal images using two-dimensional matched filters,” IEEE Transactions on Medical Imaging, vol. 8, no. 3, pp. 263–269, 1989.
[5]  M. Goldbaum, S. Moezzi, A. Taylor et al., “Automated diagnosis and image understanding with object extraction, object classification, and inferencing in retinal images,” in Proceedings of the IEEE International Conference on Image Processing (ICIP '96), pp. 695–698, September 1996.
[6]  J. Odstr?ilík, J. Jan, R. Kolar, and J. Gazarek, “Improvement of vessel segmentation by matched filtering in colour retinal images,” in Proceedings of the World Congress on Medical Physics and Biomedical Engineering (IFMBE '09), pp. 327–3330, 2009.
[7]  J. Odstr?ilík, R. Kolar, A. Budai et al., “Retinal vessel segmentation by improved matched filtering: evaluation on a new high-resolution fundus image database,” IET Image Processing, vol. 7, no. 4, pp. 373–383, 2013.
[8]  M. Sofka and C. V. Stewart, “Retinal vessel centerline extraction using multiscale matched filters, confidence and edge measures,” IEEE Transactions on Medical Imaging, vol. 25, no. 12, pp. 1531–1546, 2006.
[9]  A. Hoover, V. Kouznetsova, and M. Goldbaum, “Locating blood vessels in retinal images by piecewise threshold probing of a matched filter response,” IEEE Transactions on Medical Imaging, vol. 19, no. 3, pp. 203–210, 2000.
[10]  C.-H. Wu, G. Agam, and P. Stanchev, “A hybrid filtering approach to retinal vessel segmentation,” in Proceedings of the 4th IEEE International Symposium on Biomedical Imaging (ISBI '07), pp. 604–607, April 2007.
[11]  G. B. Kande, P. V. Subbaiah, and T. S. Savithri, “Unsupervised fuzzy based vessel segmentation in pathological digital fundus images,” Journal of Medical Systems, vol. 34, no. 5, pp. 849–858, 2010.
[12]  B. Zhang, L. Zhang, L. Zhang, and F. Karray, “Retinal vessel extraction by matched filter with first-order derivative of Gaussian,” Computers in Biology and Medicine, vol. 40, no. 4, pp. 438–445, 2010.
[13]  R. Jain, R. Kasturi, and B. Schunk, Machine Vision, McGraw-Hill, New York, NY, USA, 1995.
[14]  S. Eiho, H. Sekiguchi, N. Sugimoto, T. Hanakawa, and S. Urayama, “Branch-based region growing method for blood vessel segmentation,” in Proceedings of the International Congress for Photogrammetry and Remote Sensing, 2004.
[15]  M. J. Cree, D. Cornforth, and H. F. Jelinek, “Vessel segmentation and tracking using a two-dimensional model,” in Proceedings of the International Conference on Image and Vision Computing New Zealand (IVCNZ '05), pp. 345–350, Dunedin, New Zealand, 2005.
[16]  F. K. H. Quek and C. Kirbas, “Vessel extraction in medical images by wave-propagation and traceback,” IEEE Transactions on Medical Imaging, vol. 20, no. 2, pp. 117–131, 2001.
[17]  A. Hunter, J. Lowell, and D. Steel, “Tram-line filtering for retinal vessel segmentation,” in Proceedings of the 3rd European Medical and Biological Engineering Conference, 2005.
[18]  O. Wink, W. J. Niessen, and M. A. Viergever, “Multiscale vessel tracking,” IEEE Transactions on Medical Imaging, vol. 23, no. 1, pp. 130–133, 2004.
[19]  M. Kass, A. Witkin, and D. Terzopoulos, “Snakes: active contour models,” International Journal of Computer Vision, vol. 1, no. 4, pp. 321–331, 1988.
[20]  D. Rueckert and P. Burger, “Contour fitting using stochastic and probabilistic relaxation for Cine MR Images,” in Computer Assisted Radiology, pp. 137–142, Springer, Berlin, Germany, 1995.
[21]  M. Hinz, K. D. Toennies, M. Grohmann, and R. Pohle, “Active double-contour for segmentation of vessels in digital subtraction angiography,” in Medical Imaging 2001 Image Processing, Proceedings of SPIE, pp. 1554–1562, February 2001.
[22]  B. Al-Diri and A. Hunter, “A ribbon of twins for extracting vessel boundaries,” in Proceedings of the 3rd European Medical and Biological Engineering Conference (EMBEC '05), 2005.
[23]  R. Manniesing, M. A. Viergever, and W. J. Niessen, “Vessel axis tracking using topology constrained surface evolution,” IEEE Transactions on Medical Imaging, vol. 26, no. 3, pp. 309–316, 2007.
[24]  B. Dizdaroglu, E. Ataer-Cansizoglu, J. Kalpathy-Cramer, K. Keck, M. F. Chiang, and D. Erdogmus, “Level sets for retinal vasculature segmentation using seeds from ridges and edges from phase maps,” in Proceedings of the IEEE International Workshop on Machine Learning for Signal Processing, IEEE, Santander, Spain, September 2012.
[25]  J. Brieva, E. Gonzalez, F. Gonzalez, A. Bousse, and J. J. Bellanger, “A level set method for vessel segmentation in coronary angiography,” in Proceedings of the 27th IEEE Annual International Conference of the Engineering in Medicine and Biology Society (EMBS '05), pp. 6348–6351, IEEE, September 2005.
[26]  J. Staal, M. D. Abramoff, M. Niemeijer, M. A. Viergever, and B. van Ginneken, DRIVE public online database, http://www.isi.uu.nl/Research/Databases/DRIVE/.
[27]  L. Shi, B. Funt, and G. Hamarneh, “Quaternion color curvature,” in Proceedings of the 16th Color Imaging Conference: Color Science and Engineering Systems, Technologies, and Applications, pp. 338–341, November 2008.
[28]  M. Petrou and C. Petrou, Image Processing: The Fundamentals, John Wiley & Sons, Chichester, UK, 2nd edition, 2010.
[29]  C. Tomasi and R. Manduchi, “Bilateral filtering for gray and color images,” in Proceedings of the 6th IEEE International Conference on Computer Vision (ICCV '98), pp. 839–846, January 1998.
[30]  S. Paris, P. Kornprobst, J. Tumblin, and F. Durand, “Bilateral filtering: theory and applications,” Foundations and Trends in Computer Graphics and Vision, vol. 4, no. 1, pp. 1–73, 2009.
[31]  J. Canny, “A computational approach to edge detection,” IEEE Transactions on Pattern Analysis and Machine Intelligence, vol. 8, no. 6, pp. 679–698, 1986.
[32]  A. Hoover and M. Goldbaum, STARE public online database, http://www.ces.clemson.edu/~ahoover/stare/.
[33]  A. Budai and J. Odstr?ilík, High Resolution Fundus Image Database, September 2013.
[34]  D. Marín, A. Aquino, M. E. Gegúndez-Arias, and J. M. Bravo, “A new supervised method for blood vessel segmentation in retinal images by using gray-level and moment invariants-based features,” IEEE Transactions on Medical Imaging, vol. 30, no. 1, pp. 146–158, 2011.
[35]  J. V. B. Soares, J. J. G. Leandro, R. M. Cesar Jr., H. F. Jelinek, and M. J. Cree, “Retinal vessel segmentation using the 2-D Gabor wavelet and supervised classification,” IEEE Transactions on Medical Imaging, vol. 25, no. 9, pp. 1214–1222, 2006.
[36]  A. M. Mendon?a and A. Campilho, “Segmentation of retinal blood vessels by combining the detection of centerlines and morphological reconstruction,” IEEE Transactions on Medical Imaging, vol. 25, no. 9, pp. 1200–1213, 2006.
[37]  J. Staal, M. D. Abràmoff, M. Niemeijer, M. A. Viergever, and B. van Ginneken, “Ridge-based vessel segmentation in color images of the retina,” IEEE Transactions on Medical Imaging, vol. 23, no. 4, pp. 501–509, 2004.
[38]  M. Niemeijer, J. Staal, B. van Ginneken, M. Loog, and M. D. Abràmoff, “Comparative study of retinal vessel segmentation methods on a new publicly available database,” in Medical Imaging 2004: Image Processing, J. Michael Fitzpatrick and M. Sonka, Eds., vol. 5370 of Proceedings of SPIE, pp. 648–656, February 2004.
[39]  F. Zana and J.-C. Klein, “Segmentation of vessel-like patterns using mathematical morphology and curvature evaluation,” IEEE Transactions on Image Processing, vol. 10, no. 7, pp. 1010–1019, 2001.
[40]  M. E. Martinez-Perez, A. D. Hughes, S. A. Thom, A. A. Bharath, and K. H. Parker, “Segmentation of blood vessels from red-free and fluorescein retinal images,” Medical Image Analysis, vol. 11, no. 1, pp. 47–61, 2007.
[41]  L. Espona, M. J. Carreira, M. G. Penedo, and M. Ortega, “Comparison of pixel and subpixel retinal vessel tree segmentation using a deformable contour model,” in Progress in Pattern Recognition, Image Analysis and Applications, vol. 5197 of Lecture Notes in Computer Science, pp. 683–690, Springer, Berlin, Germany, 2008.
[42]  X. Jiang and D. Mojon, “Adaptive local thresholding by verification-based multithreshold probing with application to vessel detection in retinal images,” IEEE Transactions on Pattern Analysis and Machine Intelligence, vol. 25, no. 1, pp. 131–137, 2003.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133