A Novel Method for Ion Track Counting in Polycarbonate Detector

DOI: 10.1155/2013/286892

Full-Text   Cite this paper   Add to My Lib

Abstract:

A computer program for recognizing and counting the track of ions that are detected with polycarbonate detector has been written using MATLAB software. There are different programs for counting the track of ions in different detectors. Algorithm of this program specially has been written for polycarbonate detector and also for low magnification of optical microscope. Thus, with this method as per image of optical microscope, greater numbers of ions are visible and general distribution of ions can be better known. However, the accuracy of counting program is very high. 1. Introduction Polycarbonate is one of the detectors that is used in solid-state electrochemical etching detection method. When ions strike with polycarbonate detector, tracks are generated in detector. After several hours of etching in special solution and applying high voltage to polycarbonate, ion tracks can be seen with unaided eyes. This detection method has been being used for more than three decades by Sohrabi et al. [1–5]. After etching detector and applying high voltage to etching chamber, ion tracks must be counted and locally determined. A picture is taken from tracks, using optical microscope and CCD camera that is connected to computer. This picture is read by the proposed algorithm, and then the number of ion tracks is counted and locally determined with high accuracy. A different magnification is used for seeing the tracks. Our optical microscope has three magnification degrees: ten times, forty times, and hundred times. The goal is counting the total number of ions; therefore, if the image magnification is low, then more ion tracks can be seen in the picture and distribution will be shown better. For this reason, program algorithm is written for picture with low magnification and also it has high accuracy. 2. Algorithm of New Method A variety of methods for counting ion tracks in different detectors have been proposed so far [6–9]. The presented program in this study is written specially for the polycarbonate detector and also for low magnification. Comparison is done between pixels and this procedure continues in the whole of the picture. Using this algorithm, all of the tracks are determined and the coordinates of them are specified. Pictures of ion tracks in polycarbonate detector with high magnification are shown in Figure 1. A picture with low magnification is shown in Figure 2. Figure 1: Pictures of tracks with high magnification. Figure 2: Picture of tracks with low magnification. The algorithm of the program is as follows:?reading the image;?converting image to

References

[1]  M. Sohrabi, “A new triplet electrochemical etching (TECE) method,” Radiation Protection Dosimetry, vol. 48, no. 3, pp. 279–283, 1993.
[2]  M. Sohrabi and G. H. Zainali, “A new versatile electrochemical etching chamber (VECEC) system for multi-size and multi-shape detector processing,” Radiation Measurements, vol. 31, no. 1–6, pp. 153–156, 1999.
[3]  M. Sohrabi, “A new multi-chamber electrochemical etching system approach for rapid characteristic response studies in polymeric dosemeters,” Radiation Protection Dosimetry, vol. 12, no. 1, pp. 55–59, 1985.
[4]  M. Sohrabi and M. Sadeghi, “Efficient detection and spectrometry of alphas from radon daughters in polycarbonate,” International Journal of Radiation Applications and Instrumentation D, vol. 19, no. 1–4, pp. 421–422, 1991.
[5]  M. Sohrabi and A. Mostofizadeh, “Measurement of photoneutron doses in and out of high-energy X-ray beam of a saturne-20 medical linear accelerator by ECE polycarbonate detectors,” Radiation Measurements, vol. 31, no. 1, pp. 479–482, 1999.
[6]  D. L. Patiris, K. Blekas, and K. G. Ioannides, “TRIAC: a code for track measurements using image analysis tools,” Nuclear Instruments and Methods in Physics Research B, vol. 244, no. 2, pp. 392–396, 2006.
[7]  H. Arias, D. Palacios, L. Sajó-Bohus, and T. Viloria, “Alternative procedure for LR 115 chemical etching and alpha tracks counting,” Radiation Measurements, vol. 40, no. 2–6, pp. 357–362, 2005.
[8]  G. J. Sykora and M. S. Akselrod, “Novel fluorescent nuclear track detector technology for mixed neutron-gamma fields,” Radiation Measurements, vol. 45, no. 3–6, pp. 594–598, 2010.
[9]  L. Tsankov, D. Pressyanov, K. Mitev, S. Georgiev, and I. Dimitrova, “Automatic counting of chemically etched tracks by means of a computer scanner,” Radiation Measurements, vol. 39, no. 5, pp. 557–559, 2005.