Harmonic Mitigation Techniques Applied to Power Distribution Networks

DOI: 10.1155/2013/591680

Full-Text   Cite this paper   Add to My Lib

Abstract:

A growing number of harmonic mitigation techniques are now available including active and passive methods, and the selection of the best-suited technique for a particular case can be a complicated decision-making process. The performance of some of these techniques is largely dependent on system conditions, while others require extensive system analysis to prevent resonance problems and capacitor failure. A classification of the various available harmonic mitigation techniques is presented in this paper aimed at presenting a review of harmonic mitigation methods to researchers, designers, and engineers dealing with power distribution systems. 1. Introduction The nonlinear characteristics of many industrial and commercial loads such as power converters, fluorescent lamps, computers, light dimmers, and variable speed motor drives (VSDs) used in conjunction with industrial pumps, fans, and compressors and also in air-conditioning equipment have made the harmonic distortion a common occurrence in electrical power networks. Harmonic currents injected by some of these loads are usually too small to cause a significant distortion in distribution networks. However, when operating in large numbers, the cumulative effect has the capability of causing serious harmonic distortion levels. These do not usually upset the end-user electronic equipment as much as they overload neutral conductors and transformers and, in general, cause additional losses and reduced power factor [1–5]. Large industrial converters and variable speed drives on the other hand are capable of generating significant levels of distortion at the point of common coupling (PCC), where other users are connected to the network [6, 7]. Because of the strict requirement of power quality at the input AC mains, various harmonic standards and engineering recommendations such as IEC 1000-3-2, IEEE 519 (USA), AS 2279, D.A.CH.CZ, EN 61000-3-2/EN 61000-3-12, and ER G5/4 (UK) are employed to limit the level of distortion at the PCC. To comply with these harmonic standards, installations utilizing power electronic and nonlinear loads often use one of the growing numbers of harmonic mitigation techniques [8]. Because of the number and variety of available methods, the selection of the best-suited technique for a particular application is not always an easy or straightforward process. Many options are available, including active and passive methods. Some of the most technically advanced solutions offer guaranteed results and have little or no adverse effect on the isolated power system, while the performance of

References

[1]  A. Mansoor, W. M. Grady, A. H. Chowdhury, and M. J. Samotyi, “An investigation of harmonics attenuation and diversity among distributed single-phase power electronic loads,” IEEE Transactions on Power Delivery, vol. 10, no. 1, pp. 467–473, 1995.
[2]  A. Mansoor, W. M. Grady, R. S. Thallam, M. T. Doyle, S. D. Krein, and M. J. Samotyj, “Effect of supply voltage harmonics on the input current of single-phase diode bridge rectifier loads,” IEEE Transactions on Power Delivery, vol. 10, no. 3, pp. 1416–1422, 1995.
[3]  G. Carpinelli, F. Iacovone, P. Varilone, and P. Verde, “Single phase voltage source converters: analytical modelling for harmonic analysis in continuous and discontinuous current conditions,” International Journal of Power and Energy Systems, vol. 23, no. 1, pp. 37–48, 2003.
[4]  E. F. El-Saadany and M. M. A. Salama, “Reduction of the net harmonic current produced by single-phase non-linear loads due to attenuation and diversity effects,” International Journal of Electrical Power and Energy Systems, vol. 20, no. 4, pp. 259–268, 1998.
[5]  T. Key and J. S. Lai, “Analysis of harmonic mitigation methods for building wiring systems,” IEEE Transactions on Power Systems, vol. 13, no. 3, pp. 890–897, 1998.
[6]  M. H. Rashid and A. I. Maswood, “A novel method of harmonic assessment generated by three-phase AC-DC converters under unbalanced supply conditions,” IEEE Transactions on Industry Applications, vol. 24, no. 4, pp. 590–597, 1988.
[7]  R. E. Owen, M. F. McGranghan, and J. R. Vivirito, “Distribution system harmonics: controls for large power converters,” IEEE Transactions on Power Apparatus and Systems, vol. 101, no. 3, pp. 644–652, 1982.
[8]  T. Hoevenaars, K. LeDoux, and M. Colosino, “Interpreting IEEE STD 519 and meeting its harmonic limits in VFD applications,” in Proceedings of the 50th Annual Technical Conference of the Petroleum and Chemical Industry Committee, pp. 145–150, Houston, Tex, USA, September 2003.
[9]  B. Singh, B. N. Singh, A. Chandra, K. Al-Haddad, A. Pandey, and D. P. Kothari, “A review of three-phase improved power quality AC-DC converters,” IEEE Transactions on Industrial Electronics, vol. 51, no. 3, pp. 641–660, 2004.
[10]  “Investigation into execution of harmonic guidelines for household and office electric applications,” Japanese IEE of Japan SC77A Domestic Committee Report, 2002.
[11]  R. L. Smith and R. P. Stratford, “Power system harmonics effects from adjustable-speed drives,” IEEE Transactions on Industry Applications, vol. 20, no. 4, pp. 973–977, 1984.
[12]  J. C. Das, Power System Analysis, Short-Circuit Load Flow and Harmonics, Marcel Dekker, New York, NY, USA, 2002.
[13]  D. Alexa, A. S?rbu, and D. M. Dobrea, “An analysis of three-phase rectifiers with near-sinusoidal input currents,” IEEE Transactions on Industrial Electronics, vol. 51, no. 4, pp. 884–891, 2004.
[14]  E. B. Makram, E. V. Subramaniam, A. A. Girgis, and R. Catoe, “Harmonic filter design using actual recorded data,” IEEE Transactions on Industry Applications, vol. 29, no. 6, pp. 1176–1183, 1993.
[15]  T. S. Key and J. S. Lai, “Comparison of standards and power supply design options for limiting harmonic distortion in power systems,” IEEE Transactions on Industry Applications, vol. 29, no. 4, pp. 688–695, 1993.
[16]  A. R. Prasad, P. D. Ziogas, and S. Manias, “A novel passive waveshaping method for single-phase diode rectifiers,” IEEE Transactions on Industrial Electronics, vol. 37, no. 6, pp. 521–530, 1990.
[17]  J. Yanchao and F. Wang, “Single-phase diode rectifier with novel passive filter,” IEE Proceeding Circuits Devices Systems, vol. 145, no. 4, pp. 254–259, 1998.
[18]  K. Hirachi, T. Iwade, and K. Shibayama, “Improvement of control strategy on a step-down type high power factor converter,” National Conversion Record of Industrial Electronic Engineering Japan, pp. 4.70–4.71, 1995.
[19]  R. Ltoh, K. Lshizaka, H. Oishi, and H. Okada, “Single-phase buck rectifier employing voltage reversal circuit for sinusoidal input current waveshaping,” IEE Proceedings: Electric Power Applications, vol. 146, no. 6, pp. 707–712, 1999.
[20]  C. A. Canesin and I. Barbi, “A novel single-phase ZCS-PWM high-power-factor boost rectifier,” IEEE Transactions on Power Electronics, vol. 14, no. 4, pp. 629–635, 1999.
[21]  P. J. A. Ling and C. J. Eldridge, “Designing modern electrical systems with transformers that inherently reduce harmonic distortion in a PC-rich environment,” in Proceedings of the Power Quality Conference, pp. 166–178, 1994.
[22]  J. C. Read, “The calculation of rectifier and inverter performance characteristics,” Journal of the Institute of Electrical Engineers, vol. 92, no. 2, pp. 495–509, 1945.
[23]  E. J. Cham and T. R. Specht, “The ANSI 49 rectifier with phase shift,” IEEE Transactions on Industry Applications, vol. 20, no. 3, pp. 615–624, 1984.
[24]  R. Hammond, L. Johnson, A. Shimp, and D. Harder, “Magnetic solutions to line current harmonic reduction,” in Proceedings of the Europe by International Power Conversion Conference (PCIM '94), pp. 354–364, San Diego, Calif, USA, 1994.
[25]  S. Kim, P. N. Enjeti, P. Packebush, and I. J. Pitel, “A new approach to improve power factor and reduce harmonics in a three-phase diode rectifier type utility interface,” IEEE Transactions on Industry Applications, vol. 30, no. 6, pp. 1557–1564, 1994.
[26]  S. Choi, P. N. Enjeti, and I. J. Pitel, “Polyphase transformer arrangements with reduced kVA capacities for harmonic current reduction in rectifier-type utility interface,” IEEE Transactions on Power Electronics, vol. 11, no. 5, pp. 680–690, 1996.
[27]  B. M. Bird, J. F. Marsh, and P. R. McLellan, “Harmonic reduction in multiplex converters by triple-frequency current injection,” Proceedings of the Institution of Electrical Engineers, vol. 116, no. 10, pp. 1730–1734, 1969.
[28]  Y. S. Tzeny, “Harmonic analysis of parallel-connected 12-pulse uncontrolled rectifier without an interphase transformer,” IEE Proceeding Electrical Power Applications, vol. 145, no. 3, pp. 253–260, 1998.
[29]  M. Hink Karl, “18 -Pulse Drives and Voltage Unbalance,” http://mtecorp.com/18pulse.html.
[30]  T. H. Chen and M. Y. Huang, “Network modelling of 24-pulse rectifier transformers for rigorous simulation of rail transit power systems,” Electric Power Systems Research, vol. 50, no. 1, pp. 23–33, 1999.
[31]  E. F. El-Saadany, R. Elshatshat, M. M. A. Salama, M. Kazerani, and A. Y. Chikhani, “Reactance one-port compensator and modular active filter for voltage and current harmonic reduction in nonlinear distribution systems: a comparative study,” Electric Power Systems Research, vol. 52, no. 3, pp. 197–209, 1999.
[32]  J. R. Johnson, “Proper use of active harmonic filters to benefit pulp and paper mills,” IEEE Transactions on Industry Applications, vol. 38, no. 3, pp. 719–725, 2002.
[33]  D. Li, Q. Chen, Z. Jia, and J. Ke, “A novel active power filter with fundamental magnetic flux compensation,” IEEE Transactions on Power Delivery, vol. 19, no. 2, pp. 799–805, 2004.
[34]  W. M. Grady, M. J. Samotyi, and A. H. Noyola, “Survey of active line conditioning methodologies,” IEEE Transactions on Power Delivery, vol. 5, no. 3, pp. 1536–1541, 1990.
[35]  M. Takeda, K. Ikeda, and Y. Tominaga, “Harmonic current compensation with active filter,” in Proceedings of the IEEE/IAS Annual Meeting, pp. 808–815, 1987.
[36]  Z. Du, L. M. Tolbert, and J. N. Chiasson, “Active harmonic elimination for multilevel converters,” IEEE Transactions on Power Electronics, vol. 21, no. 2, pp. 459–469, 2006.
[37]  S. Bhattacharya, T. M. Frank, D. M. Divan, and B. Banerjee, “Active filter system implementation,” IEEE Industry Applications Magazine, vol. 4, no. 5, pp. 47–63, 1998.
[38]  I. Takahashi, S. G. Li, and Y. Omura, “Low price and high power active filter,” in Proceedings of the IEEE/IAS Annual Meeting, pp. 95–98, 1991.
[39]  G. W. Chang and T. C. Shee, “A novel reference compensation current strategy for shunt active power filter control,” IEEE Transactions on Power Delivery, vol. 19, no. 4, pp. 1751–1758, 2004.
[40]  H. Akagi, “Control strategy and site selection of a shunt active filter for damping of harmonic propagation in power distribution systems,” IEEE Transactions on Power Delivery, vol. 12, no. 1, pp. 354–362, 1997.
[41]  A. Cavallini and G. C. Montanari, “Compensation strategies for shunt active-filter control,” IEEE Transactions on Power Electronics, vol. 9, no. 6, pp. 587–593, 1994.
[42]  H. Akagi, H. Fujita, and K. Wada, “A shunt active filter based on voltage detection for harmonic termination of a radial power distribution line,” IEEE Transactions on Industry Applications, vol. 35, no. 3, pp. 638–645, 1999.
[43]  H. Fujita and H. Akagi, “A practical approach to harmonic compensation in power systems—series connection of passive and active filters,” IEEE Transactions on Industry Applications, vol. 27, no. 6, pp. 1020–1025, 1991.
[44]  F. Z. Peng, H. Akagi, and A. Nabae, “A new approach to harmonic compensation in power systems—a combined system of shunt passive and series active filters,” IEEE Transactions on Industry Applications, vol. 26, no. 6, pp. 983–990, 1990.
[45]  H. Akagi, “Active harmonic filters,” Proceedings of the IEEE, vol. 93, no. 12, pp. 2128–2141, 2005.
[46]  D. Basic, V. S. Ramsden, and P. K. Muttik, “Hybrid filter control system with adaptive filters for selective elimination of harmonics and interharmonics,” IEE Proceedings: Electric Power Applications, vol. 147, no. 4, pp. 295–303, 2000.
[47]  S. Senini and P. J. Wolfs, “Hybrid active filter for harmonically unbalanced three phase three wire railway traction loads,” IEEE Transactions on Power Electronics, vol. 15, no. 4, pp. 702–710, 2000.
[48]  P. Salmerón, J. C. Montano, J. R. Vázquez, J. Prieto, and A. Pérez, “Compensation in nonsinusoidal, unbalanced three-phase four-wire systems with active power-line conditioner,” IEEE Transactions on Power Delivery, vol. 19, no. 4, pp. 1968–1974, 2004.
[49]  H. Akagi, “New trends in active filters for power conditioning,” IEEE Transactions on Industry Applications, vol. 32, no. 6, pp. 1312–1322, 1996.
[50]  H. L. Jou, J. C. Wu, and K. D. Wu, “Parallel operation of passive power filter and hybrid power filter for harmonic suppression,” IEE Proceedings: Generation, Transmission and Distribution, vol. 148, no. 1, pp. 8–14, 2001.
[51]  X. Zha and Y. Chen, “The iterative learning control strategy for hybrid active filter to dampen harmonic resonance in industrial power system,” in Proceedings of the IEEE International Symposium on Industrial Electronics, vol. 2, pp. 848–853, 2003.
[52]  B. Singh, K. Al-Haddad, and A. Chandra, “A review of active filters for power quality improvement,” IEEE Transactions on Industrial Electronics, vol. 46, no. 5, pp. 960–971, 1999.
[53]  B. R. Lin, B. R. Yang, and H. R. Tsai, “Analysis and operation of hybrid active filter for harmonic elimination,” Electric Power Systems Research, vol. 62, no. 3, pp. 191–200, 2002.
[54]  D. Chen and S. Xie, “Review of the control strategies applied to active power filters,” in Proceedings of the IEEE International Conference on Electric Utility Deregulation, Restructuring and Power Technologies (DRPT '04), pp. 666–670, April 2004.
[55]  K. Zhou, Z. Lv, A. Luo, and L. Liu, “Control strategy of shunt hybrid active power filter in distribution network containing distributed power,” in Proceedings of the China International Conference on Electricity Distribution (CICED '10), pp. 1–10, September 2010.
[56]  D. Detjen, J. Jacobs, R. W. De Doncker, and H. G. Mall, “A new hybrid filter to dampen resonances and compensate harmonic currents in industrial power systems with power factor correction equipment,” IEEE Transactions on Power Electronics, vol. 16, no. 6, pp. 821–827, 2001.
[57]  M. Aredes, J. H?fner, and K. Heumann, “Three-phase four-wire shunt active filter control strategies,” IEEE Transactions on Power Electronics, vol. 12, no. 2, pp. 311–318, 1997.
[58]  M. Aredes, L. F. C. Monteiro, and J. M. Miguel, “Control strategies for series and shunt active filters,” in Proceedings of the IEEE Bologna Power Tech Conference, pp. 1–6, June 2003.
[59]  S. Khalid and A. Triapthi, “comparison of sinusoidal current control strategy & synchronous rotating frame strategy for total harmonic reduction for power electronic converters in aircraft system under different load conditions,” International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering, vol. 1, no. 4, pp. 305–313, 2012.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133