Background We aimed to assess, for the first time, the nature of the indoor air contamination of hospitals. Methods and Findings More than 40 volatile organic compounds (VOCs) including aliphatic, aromatic and halogenated hydrocarbons, aldehydes, alcohols, ketones, ethers and terpenes were measured in a teaching hospital in France, from sampling in six sampling sites – reception hall, patient room, nursing care, post-anesthesia care unit, parasitology-mycology laboratory and flexible endoscope disinfection unit – in the morning and in the afternoon, during three consecutive days. Our results showed that the main compounds found in indoor air were alcohols (arithmetic means ± SD: 928±958 μg/m3 and 47.9±52.2 μg/m3 for ethanol and isopropanol, respectively), ethers (75.6±157 μg/m3 for ether) and ketones (22.6±20.6 μg/m3 for acetone). Concentrations levels of aromatic and halogenated hydrocarbons, ketones, aldehydes and limonene were widely variable between sampling sites, due to building age and type of products used according to health activities conducted in each site. A high temporal variability was observed in concentrations of alcohols, probably due to the intensive use of alcohol-based hand rubs in all sites. Qualitative analysis of air samples led to the identification of other compounds, including siloxanes (hexamethyldisiloxane, octamethyltrisiloxane, decamethylcyclopentasiloxane), anesthetic gases (sevoflurane, desflurane), aliphatic hydrocarbons (butane), esters (ethylacetate), terpenes (camphor, α-bisabolol), aldehydes (benzaldehyde) and organic acids (benzoic acid) depending on sites. Conclusion For all compounds, concentrations measured were lower than concentrations known to be harmful in humans. However, results showed that indoor air of sampling locations contains a complex mixture of VOCs. Further multicenter studies are required to compare these results. A full understanding of the exposure of healthcare workers and patients to complex mixtures of chemical compounds can then be related to potential health outcomes.
References
[1]
ISIAQ (International Society of Indoor Air Quality and Climate) (2003) Review on indoor air quality in hospitals and other health care facilities, 43 p.
[2]
Hellgren UM, Palomaki E, Lahtinen M, Riuttala H, Reijula K (2008) Complaints and symptoms among hospital staff in relation to indoor air and the condition and need for repairs hospital buildings. Scand J Work Env Health 4: 58–63.
[3]
Dascalaki EG, Gaglia AG, Balaras C, Lagoudi A (2009) Indoor environmental quality in Hellenic hospital operating rooms. Energy and Buildings 41: 551–560.
[4]
Hellgren UM, Hyv?rinen M, Holopainen R, Reijula K (2011) Perceived indoor air quality, air-related symptoms and ventilation in Finnish hospitals. Int J Occup Med Environ Health 24: 48–56.
[5]
Glumbakait E, ?ymantien Z, ?e?kauskas V, Smolianskien G, Jurkuv?nas V (2003) Quality of the air and health assessment of the medical staff handling disnfection chemicals in Lithunian hospitals. Indoor Built Environ 12: 105–111.
[6]
Di Stefano F, Siriruttanapruk S, McCoach J, Burge PS (1999) Glutaraldehyde: an occupational hazard in the hospital setting. Allergy 54: 1105–1109.
[7]
Dascalaki EG, Lagoudi A, Balaras CA, Gaglia AG (2008) Air quality in hospital operating rooms. Building Environ 43: 1945–1952.
[8]
Ghasemkhani M, Jahanpeyma F, Azam K (2005) Formaldehyde exposure in some educational hospitals of Tehran. Ind Health 43: 703–707.
[9]
Sobaszek A, Hache JC, Frimat P, Akakpo V, Victoire G, et al. (1999) Working conditions and health effects of ethylene oxide exposure at Hospital sterilization sites. J Occup Environ Med 41: 492–499.
[10]
Takigawa T, Horike T, Ohashi Y, Kataoka H, Wang D, et al. (2004) Were volatile organic compounds the inducing factors for subjective symptoms of employees working in newly constructed hospitals? Environ Toxicol 19: 280–290.
[11]
Lü H, Wen S, Feng Y, Wang X, Bi X, et al. (2006) Indoor and outdoor carbonyl compounds and BTEX in the hospitals of Guangzhou, China. Sci Tot Environ 368: 574–584.
[12]
Lü H, Cai QY, Wen S, Chi Y, Guo S, et al. (2010) Carbonyl compounds and BTEX in the special rooms of hospital in Guangzhou, China. J Hazar Mater 178: 673–679.
[13]
Plieninger P, Hofer T (2001) Eye irritation and cognition disorders in a hospital with aldehydes and glycol ethers as indoor contaminants. Gefahrstoffe Reinhalt Luft 61: 521–527.
[14]
Bessonneau V, Clément M, Thomas O (2010) Can intensive use of alcohol-based hand rubs lead to passive alcoholization? Int J Environ Res Public Health 7: 3038–3050.
[15]
Bessonneau V, Thomas O (2012) Assessment of exposure to alcohol vapor from alcohol-based hand rubs. Int J Environ Res Public Health 9: 868–879.
[16]
Heudorf U, Mersch-Sundermann V, Angerer J (2007) Phatalates: toxicology and exposure. Int J Hyg Environ Health 210: 623–634.
[17]
Borhnehag CG, Sundell J, Weschler CJ, Sigsgaard T, Lundgren B, et al. (2004) The association between asthma and allergic symptoms in children and phtalates in house dust: a nested case-control study. Environ Health Perspect 112: 1393–1397.
Saad SG (2003) Integrated environmental management for hospitals. Indoor Built Environ 12: 93–98.
[20]
Korpi A, J?rnberg J, Pasanen AL (2009) Microbial volatile organic compounds. Crit Rev Toxicol 39: 139–193.
[21]
Berrube A (2011) Cartographie du risque chimique par inhalation dans le milieu hospitalier: faisabilité de la mise en ?uvre par une enquête in situ. Mémoire d'Ingénieur du Génie Sanitaire. EHESP.
[22]
Ras MR, Borrull F, Marcé RL (2009) Sampling and preconcentration techniques for détermination of volatile organic compounds in air samples. Trends Anal Chem 28: 347–361.
[23]
Gallego E, Roca FJ, Perales JF, Guardino X (2011) Comparative study of the adsorption performance of an active multi-sorbent bed tube (Carbotrap, Carbopack X, Carboxen 569) and a Radiello? diffusive sampler for the analysis of VOCs. Talanta 85: 662–672.
[24]
Gallego E, Roca FJ, Perales JF, Guardino X (2010) Comparative study of the adsorption performance of a multi-sorbent bed (Carbotrap, Carbopack X, Carboxen 569) and a Tenax TA adsorbent tube for the analysis of volatile organic compounds (VOCs). Talanta 81: 916–924.
[25]
Ribes A, Carrera G, Gallego E, Roca X, Berenguer MJ, et al. (2007) Development and validation of a method for air-quality and nuisance odors monitoring of volatile organic compounds using multi-sorbent adsorption and gas chromatography/mass spectrometry thermal désorption system. J Chromtograph A 1140: 44–55.
[26]
Geiss O, Giannopoulos G, Tirendi S, Barrero-Moreno J, Larsen BR, et al. (2011) The AIRMEX study – VOC measurments in public buildings and schools/kindergartens in eleven European cities: Statistical analysis of data. Atmos Environ 45: 3676–3684.
[27]
Mosqueron L, Nedellec V (2004) Inventaire des données fran?aises sur la qualité de l'air à l'intérieur des batiments: actualisation des données sur la période 2001–2004. Rapport OQAI. Available: http://www.oqai.fr/userdata/documents/Do?cument_16.pdf. Accessed 2012 Jun 11.
[28]
Bruno P, Caselli M, de Gennaro G, Lacobellis S, Tutino M (2008) Monitoring of volatile organic compounds in non-residential indoor environments. Indoor Air 18: 250–256.
[29]
Zabiegala B (2006) Organic compounds in indoor environments. Polish J Environ Stud 15: 383–393.
[30]
World Health Organization (2010) WHO guidelines for indoor air quality: selected pollutants. Available: www.euro.who.int/__data/assets/pdf_file/?0009/…/e94535.pdf. Accessed 2012 Jun 21.
[31]
Kirchner S, Arenes JF, Cochet C, Derbez M, Duboudin C, et al.. (2006) National survey: Indoor air quality in French dwellings. Final report. Available: http://www.developpement-durable.gouv.fr?/IMG/pdf/OQAI.pdf. Accessed 2012 Jun 21.
[32]
Ohura T, Amagai T, Senga Y, Fusaya M (2006) Organic air pollutants inside and outside residences in Shimizu, Japan: Levels, sources and risks. Sci Tot Environ 366: 485–499.
[33]
Kramer A, Below H, Bieber N, Kampf G, Toma CD, et al. (2007) Quantity of ethanol absorption after excessive hand disinfection using three commercialy available hand rubs is minimal and below toxic levels in humans. BMC Infect Dis 7: 117–129.
[34]
Miller MA, Rosin A, Levsky ME, Patel MM, Gregory TJD, et al. (2006) Does the clinical use of ethanol-based hand sanitizer elevate blood alcohols levels? A prospective study. Am J Emerg Med 24: 815–817.
[35]
Reisfield GM, Goldberger BA, Crews BO, Pesce AJ, Wilson GR, et al. (2011) Ethyl glucuronide, ethyl sulfate, and ethanol in urine after sustained exposure to an ethanol-based hand sanitizer. J Anal Toxicol 35: 85–91.
[36]
Reisfield GM, Goldberger BA, Crews BO, Pesce AJ, Wilson GR, et al. (2011) Ethyl glucuronide, ethyl sulfate, and ethanol in urine after intensive exposure to high ethanol content mouthwash. J Anal Toxicol 35: 264–268.
[37]
Dutch Expert Committee on Occupational Standards (2006) Ethanol (Ethyl Alcohol): Evaluation of the health effects from occupational exposure. Available: http://www.gezondheidsraad.nl/sites/defa?ult/files/200606OSH.pdf. Accessed 2012 Jun 21.
[38]
Norliana S, Abdulamir AS, Abu Bakar F, Salleh AB (2009) The health risk of formaldehyde to human being. Am J Pharmacol Toxicol 4: 98–106.
[39]
Lu Y, Yuan T, Yun SH, Wang W, Wu Q, et al. (2010) Occurence of cyclic and linear siloxanes in indoor dust from China, and implications for human exposures. Environ Sci Technol 44: 6081–6087.
[40]
Singer BC, Destaillats H, Hodgson AT, Nazaroff WW (2006) Cleaning products and air fresheners: emissions and resulting concentrations of glycol ethers and terpenoids. Indoor Air 16: 179–191.
[41]
Tsigonia A, Lagoudi A, Chandrinou S, Linos A, Evlogias N, et al. (2010) Indoor air in beauty salons and occupational health exposure of cosmetologists to chemical substances. Int J Environ Res Public Health 7: 314–324.
[42]
Xhauflaire-Uhoda E, Macarenko E, Denooz R, Charlier C, Piérard GE (2008) Skin protection creams in medical settings: successful or evil? J Occup Med Toxicol 3: 15.
[43]
Koda S, Kumagai S, Ohara H (1999) Environmental monitoring and assessment of short-term exposures to hazardous chemicals of a sterilization process in hospital working environments. Acta Med Okayama 53: 217–223.
[44]
Pacenti M, Dugheri S, Pieraccini G, Boccalon P, Arcangeli G, et al. (2006) Evaluation of the occupational exposure to glutaraldehyde in some endoscopic services in an Italian hospital. Indoor Built Environ 15: 63–68.
[45]
Kang MS, Hong JR, Gil HW, Yang JO, Lee EY, et al. (2008) Benzene and toluene concentrations in a hemodialysis room in a medium sized South Korean city. Korean J Intern Med 23: 111–115.