Preparation Procedure of Liposome-Absorbed Substrate and Tip Shape Correction of Diameters of Liposome Measured by AFM

DOI: 10.4236/mr.2013.13005, PP. 24-28

Keywords: Atomic Force Microscope (AFM), Dynamic Light Scattering (DLS), Anionic Liposome, 3-Aminopropyltriethoxysilane (APTES)

Full-Text   Cite this paper   Add to My Lib

Abstract:

The procedure to measure liposome in aqueous solution has been examined using atomic force microscope (AFM). We concluded a chemical modified silicon wafer (substrate for AFM observation of liposome) with 3-aminopropyltrieth-oxysilane (APTES) which enabled us to scan anionic liposome softly in water because they were keeping structures as vesicles and stably adsorbed on the substrate by electrostatic force. From captured AFM topographic images, we counted the amount of liposome and analyzed the distribution of mean diameters, which were corrected by an approximated curve of the tip shape. We discussed the method of effective evaluation as practical analysis and its problems for robust analysis.

References

[1]  G. Binnig, C. F. Quate and Ch. Gerber, “Atomic Force Microscope,” Physical Review Letters, Vol. 56, No. 9, 1986, pp. 930-933. http://dx.doi.org/10.1103/PhysRevLett.56.930
[2]  H. Egawa and K. Furusawa, “Liposome Adhesion on Mica Surface Studied by Atomic Force Microscopy,” Langmuir, Vol. 15, No. 5, 1999, pp. 1660-1666. http://dx.doi.org/10.1021/la980923w
[3]  N. H. Thomson, I. Collin, M. C. Davis, K. Palin, D. Parkins, C. J. Roberts, S. J. Tendler and P. M. Williams, “Atomic Force Microscopy of Cationic Liposomes,” Langmuir, Vol. 16, No. 11, 2000, pp. 4813-4818. http://dx.doi.org/10.1021/la991256p
[4]  J. Jass, T. Tjarnhage and G. Puu, “From Liposomes to Supported, Planar Bilayer Structures on Hydrophilic and Hydrophobic Surfaces: An Atomic Force Microscopy Study,” Biophysical Journal, Vol. 79, No. 6, 2000, pp. 3153-3163. http://dx.doi.org/10.1016/S0006-3495(00)76549-0
[5]  K. Nakano, Y. Tozuka, H. Yamamoto, Y. Kawashima and H. Takeuchi, “A Novel Method for Measuring Rigi- dity of Submicron-Size Liposomes with Atomic Force Microscopy,” International Journal of Pharmaceutics, Vol. 355, No. 1-2, 2008, pp. 203-209. http://dx.doi.org/10.1016/j.ijpharm.2007.12.018
[6]  B. Pignataro, C. Steinem, H. J. Galla, H. Fuchs and A. Janshoff, “Specific Adhesion of Vesicles Monitored by Scanning Force Microscopy and Quartz Crystal Micro- balance,” Biophysical Journal, Vol. 78, No. 1, 2000, pp. 487-498. http://dx.doi.org/10.1016/S0006-3495(00)76611-2