全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
Engineering  2013 

Study of Situation Based Environment towards Noise Reduction during ECG Acquisition

DOI: 10.4236/eng.2013.55B002, PP. 6-9

Keywords: Electrocardiogram, Electromagnetic Interference, R-R Peak Distance

Full-Text   Cite this paper   Add to My Lib

Abstract:

Even with the development of more advanced technology of ECG, there are still problems on interference to ECG signals. Many attempts have been made to detect and eliminate the source of noises and artifacts from the original ECG signals. Several studies have been done to observe and study the EMI effect, however, most of them only focus on the EMI effect of mobile phone during ECG acquisition. Thus, this study is emphasized on the interference problem when other medical devices were being used together with the ECG device. The R-R peak distance of the ECG signal was detected by using QRS detection algorithm invented by J. Pan and W. J. Tompkins. The data from the experiment showed that even the EMI from the medical devices did not affect the physical shape of ECG, but it does affect the R-R peak distance of the ECG signal.

References

[1]  M. Lin and E. Peper, “Keep Cell Phones and PDAs Away from EMG Sensors And the Human Body to Prevent Electromagnetic Interference Artifacts and Cancer,” Biofeedback, Vol. 37, No. 3, 2009, pp. 114-116. doi:10.5298/1081-5937-37.3.114
[2]  A. Escobar and H. Cadavid, “Electromagnetic Field Environment in a Typical Hospital,” ANDESCON 2010, pp. 1-4, 2010.
[3]  W. Y. Wong, R. Sudirman, N. H. Mahmood, S. Z. Tumari and N. Samad, “Study of Environment Based Condition of Electromagnetic Interference During ECG Acquisition,” International Conference on Biomedical Engineering, ICOBE, 2012, pp. 579-584.
[4]  M. P. Robinson and N. J. Wainwright, “EMC of Medical Equipment,” York EMC Services Ltd, University of York, Heslington, 1999.
[5]  K. S. Tan, I. Hinberg, “Radiofrequency Susceptibility Tests on Medical Equipment,” Engineering in Medicine and Biology Society, Engineering Advances: New Opportunities for Biomedical Engineers, Proceedings of the 16th Annual International Conference of the IEEE, Vol. 2, 1994, pp. 998-999.
[6]  S. C. B. Cabral and S. S. Muhlen, “Methodology for Identification of Susceptible Areas to Electromagnetic Interference in the Hospital,” Annual International Conference of the IEEE, Vol. 4, 2003, pp. 3606-3608.
[7]  M. Fernandez-Chimeno and F. Silva, “Mobile Phones Electromagnetic Interference in Medical Environments: A Review,” Electromagnetic Compatibility (EMC), IEEE International Symposium, 2010, pp. 311-316.
[8]  W. H. Midgette and J. L. Silberberg, “Medical Device Electromagnetic Interference Problems: A Limited Review,” Engineering in Medicine and Biology Society, 14th Annual International Conference of the IEEE, Vol. 7, pp. 2837-2838.
[9]  J. Pan, W. J. Tompkins, “A Real-Time QRS Detection Algorithm,” Biomedical Engineering, IEEE Transactions, Vol. BME-32, No. 3, 1985, pp. 230-236.
[10]  M. K. Islam, A. N. M. Haque, G. Tangim, T. Ahammad and M. R. H. Khondokar, “Study and Analysis of ECG Signal Using Matlab & Labview As Effective Tools,” International Journal of Computer and Electrical Engineering, Vol. 4, No. 3, 2012.
[11]  R. Ranjan and V. K. Giri, “A Unified Approach of ECG Signal Analysis,” International Journal of Soft Computing and Engineering (IJSCE), Vol. 2, No. 3, 2012.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133