PIV measurement of constant area mixing in subsonic air ejector

DOI: 10.1051/epjconf/20122501011

Full-Text   Cite this paper   Add to My Lib

Abstract:

The article deals with experimental study of constant area mixing in subsonic axi-symmetric air ejector. The velocity fields inside the constant area mixing chamber were taken through the vitreous wall of the chamber, while the laser beam entered it from the opened outflow of the ejector. PIV measurements of four different mixing regimes, each with different ejection ratio were performed. Basic description of results are given and it is claimed that results are reliable. Obtained data will be later compared with constant temperature anemometry and with numerical calculations.