In this work, active vibration control of an underwater cylindrical shell structure was investigated, to suppress structural vibration and structure-borne noise in water. Finite element modeling of the submerged cylindrical shell structure was developed, and experimentally evaluated. Modal reduction was conducted to obtain the reduced system equation for the active feedback control algorithm. Three Macro Fiber Composites (MFCs) were used as actuators and sensors. One MFC was used as an exciter. The optimum control algorithm was designed based on the reduced system equations. The active control performance was then evaluated using the lab scale underwater cylindrical shell structure. Structural vibration and structure-borne noise of the underwater cylindrical shell structure were reduced significantly by activating the optimal controller associated with the MFC actuators. The results provide that active vibration control of the underwater structure is a useful means to reduce structure-borne noise in water.
References
[1]
Crawley, E.F.; De Luis, J. Use of piezoelectric actuators as elements of intelligent structures. AIAA J. 1987, 25, 1373–1385.
[2]
Chopra, I. Review of state of art of smart structures and integrated systems. AIAA J. 2002, 40, 2145–2187.
[3]
Tzou, H.S.; Zhong, J.P.; Hollkamp, J.J. Spatially distributed orthogonal piezoelectric shell actuators: Theory and applications. J. Sound Vibr. 1994, 177, 363–378.
[4]
Lester, H.C.; Lefebvre, S. Piezoelectric actuator models for active sound and vibration control of cylinders. J. Intell. Mater. Syst. Struct. 1993, 4, 295–306.
[5]
Pan, X.; Hansen, C.H. Active control of vibration transmission in a cylindrical shell. J. Sound Vibr. 1997, 203, 409–434.
[6]
Maillard, J.P.; Fuller, C.R. Active control of sound radiation from cylinders with piezoelectric actuators and structural acoustic sensing. J. Sound Vibr. 1999, 222, 363–387.
[7]
Kim, H.S.; Chattopadhyay, A.; Nam, C.H. Implementation of a coupled thermo-piezdelectric-mechanical model in the LQG controller design for smart composite shells. J. Intell. Mater. Syst. Struct. 2002, 13, 713–724.
[8]
Sohn, J.W.; Kim, H.S.; Choi, S.B. Active vibration control of smart hull structures using piezoelectric actuators. J. Mech. Eng. Sci. 2006, 220, 1329–1337.
[9]
Pan, X.; Tso, Y.; Juniper, R. Active control of radiated pressure of a submarine hull. J. Sound Vibr. 2008, 311, 224–242.
[10]
Pan, X.; Tso, Y.; Juniper, R. Active control of low-frequency hull-radiated noise. J. Sound Vibr. 2008, 313, 29–45.
[11]
Wilkie, W.K.; Bryant, R.G.; High, J.W.; Fox, R.L.; Hellbaum, R.F.; Jalink, J.A.; Little, B.D.; Mirick, P.H. Low-cost piezocomposite actuator for structural control applications. Proc. SPIE 2000, 3991, 323–334.
[12]
Williams, R.B.; Inman, D.J.; Schultz, M.R.; Hyer, M.W.; Wilkie, W.K. Nonlinear tensile and shear behavior of macro fiber composite actuators. J. Compos. Mater. 2004, 38, 855–869.
[13]
Azzouz, M.S.; Mei, C.; Bevan, J.S.; Ro, J.J. Finite element modeling of MFC/AFC actuators and performance of MFC. J. Intell. Mater. Syst. Struct. 2001, 12, 601–612.
[14]
Sodano, H.A.; Park, G.; Inman, D.J. An investigation into the performance of macro-fiber composites for sensing and structural vibration applications. Mech. Syst. Sign. Process. 2004, 18, 683–697.
[15]
Choi, S.C.; Park, J.S.; Kim, J.H. Vibration control of pre-twisted rotating composite thin-walled beams with piezoelectric fiber composites. J. Sound Vibr. 2007, 300, 176–196.
[16]
Dano, M.L.; Julliere, B. Active control of thermally induced distortion in composite structures using Macro Fiber Composite actuators. Smart Mater. Struct. 2007, 16, 2315–2322.
[17]
Barkanov, E.; Gluhih, S.; Kovalov, A. Optimal design of the active twist for helicopter rotor blades with C-spar. Mech. Adv. Mater. Struct. 2008, 15, 325–334.
[18]
Binette, P.; Dano, M.L.; Gendron, G. Active shape control of composite structures under thermal loading. Smart Mater. Struct. 2009, 18, doi:10.1088/0964-1726/18/2/025007.
[19]
Vadiraja, D.N.; Sahasrabudhe, A.D. Vibration and control of rotating tapered thin-walled composite beam using macro fiber composite actuator. Comput. Model. Eng. Sci. 2008, 27, 49–62.
[20]
Vadiraja, D.N.; Sahasrabudhe, A.D. Vibration analysis and optimal control of rotating pre-twisted thin-walled beams using MFC actuators and sensors. Thin Wall Struct 2009, 47, 555–567.
[21]
Bilgen, O.; Kochersberger, K.B.; Inman, D.J. Macro-fiber composite actuators for a swept wing unmanned aircraft. Aeronaut. J. 2009, 113, 385–395.
Sohn, J.W.; Choi, S.; Lee, C. Active vibration control of smart hull structure using piezoelectric composite actuators. Smart Mater. Struct. 2009, 18, doi:10.1088/0964-1726/18/7/074004.
[24]
Sohn, J.W.; Choi, S.B.; Kim, H.S. Vibration control of smart hull structure with optimally placed piezoelectric composite actuators. Int. J. Mech. Sci. 2011, 53, 647–659.
[25]
Zhang, Z.Y.; Chen, Y.; Yin, X.W.; Hua, H.X. Active vibration isolation and underwater sound radiation control. J. Sound Vibr. 2008, 318, 725–736.
[26]
Zhang, Z.; Huang, X.; Chen, Y.; Hua, H. Underwater sound radiation control by active vibration isolation: An experiment. Proc. Instit. Mech. Eng. 2009, 223, 503–515.
[27]
Caresta, M. Active control of sound radiated by a submarine in bending vibration. J. Sound Vibr. 2011, 330, 615–624.
[28]
ANSYS Theory Manual; Version 5.5; ANSYS Inc.: Canonsburg, PA, USA, 1999.