This paper presents a fully differential single-axis accelerometer fabricated using the MetalMUMPs process. The unique structural configuration and common-centriod wiring of the metal electrodes enables a fully differential sensing scheme with robust metal sensing structures. CoventorWare is used in structural and electrical design and simulation of the fully differential accelerometer. The MUMPs foundry fabrication process of the sensor allows for high yield, good process consistency and provides 20 μm structural thickness of the sensing element, which makes the capacitive sensing eligible. In device characterization, surface profile of the fabricated device is measured using a Veeco surface profilometer; and mean and gradient residual stress in the nickel structure are calculated as approximately 94.7 MPa and ?5.27 MPa/μm, respectively. Dynamic characterization of the sensor is performed using a vibration shaker with a high-end commercial calibrating accelerometer as reference. The sensitivity of the sensor is measured as 0.52 mV/g prior to off-chip amplification. Temperature dependence of the sensing capacitance is also characterized. A ?0.021fF/°C is observed. The findings in the presented work will provide useful information for design of sensors and actuators such as accelerometers, gyroscopes and electrothermal actuators that are to be fabricated using MetalMUMPs technology.
References
[1]
Liu, M.; Lau, W.M.; Yang, J. On-demand multi-batch self-assembly of hybrid MEMS by patterning solders of different melting points. J. Micromech. Microeng. 2007, 17, 2163–2168.
[2]
Riaz, K.; Bazazc, S.A.; Saleemb, M.M.; Shakoor, R.I. Design damping estimation and experimental characterization of decoupled 3-DoF robust MEMS gyroscope. Sens. Actuators A Phys. 2011, 172, 523–532.
[3]
Shakoor, R.I.; Srinivasan, P.; Bazaz, S.A. Performance of a Compliant Structure for a thermal resonant microgyroscope. IEEE Sens. J. 2011, 11, 1465–1475.
[4]
Yang, P. Development of Micro Thermal Actuator with Capacitive Sensor. Ms. Thesis, Queen's University, Kingston, ON, Canada, 2009.
[5]
Iqbal, A.; Bazaz, S.A. Behavioral modeling of a monolithically integrated three-axis capacitive accelerometer based on the MetalMUMPs process. Simulation 2012, 88, 565–579.
[6]
Cowen, A.; Dudley, B.; Hill, E.; Walters, M.; Wood, R.; Johnson, S.; Wynands, H.; Hardy, B. MetalMUMPs Design Handbook; MEMSCAP Inc.: Durham, NC, USA, 2009.
[7]
Alper, S.E.; Silay, K.M.; Akin, T. A low-cost rate-grade nickel microgyroscope. Sens. Actuators A Phys. 2006, 132, 171–181.
[8]
Saleem, M.; Bazaz, S. Design and robustness analysis of structurally decoupled 3-DoF MEMS gyroscope in the presence of worst-case process tolerances. Microsyst. Technol. 2011, 17, 1381–1391.
[9]
Shakoor, R.I.; Bazaz, S.A.; Hasan, M.M. Design Modeling and Simulation of Electrothermally Actuated Microgyroscope Fabricated Using the MetalMUMPs. Proceedings of the 15th International Workshop on Thermal Investigations of ICs and Systems, Leuven, Belgium, 7–9 October 2009; pp. 40–44.
[10]
Yang, P.; Mechefske, C.; Lai, Y. Micro Thermal Actuator with Integrated Capacitive Position Sensor. Proceedings of the 2nd Microsystems and Nanoelectronics Research Conference, Ottawa, ON, Canada, 13–14 October 2009; pp. 25–28.
[11]
He, S.; Chang, J.S.; Li, L.; Ho, H. Characterization of Young's modulus and residual stress gradient of MetalMUMPs electroplated nickel film. Sens. Actuators A Phys. 2009, 154, 149–156.
[12]
Baumert, E.K.; Pierron, O.N. Very high cycle fatigue crack initiation in electroplated Ni films under extreme stress gradients. Scripta Materialia 2012, 67, 45–48.
[13]
Fedder, G.K. Simulation of Microelectromechnical Systems. Ph.D. Thesis, University of California, Berkeley, CA, USA, 1994.
[14]
Qu, H.; Fang, D.; Xie, H. A monolithic CMOS-MEMS 3-axis accelerometer with a low-noise, low-power dual-chopper amplifier. IEEE Sens. J. 2008, 8, 1511–1518.
[15]
Senturia, S.D. Microsystem Design; Springer-Verlag: New York, NY, USA, 2000.
[16]
Fang, W.; Wickert, A.J. Determining mean and gradient residual stresses in thin films using micromachined cantilevers. J. Micromech. Microeng. 1996, 6, S301–S309.
[17]
Van Drie?nhuizen, B.P.; Goosen, J.F.L.; French, P.J.; Wolffenbuttel, R.F. Comparison of techniques for measuring both compressive and tensile stress in thin films. Sens. Actuators A Phys. 1993, 37, 756–765.
[18]
Chu, W.H.; Mehregany, M.A. Study of residual stress distribution through the thickness of p+ silicon films. IEEE Trans. Electron. Device. 1993, 40, 1245–1250.
[19]
Ericson, F.; Greek, S.; S?derkvist, J.; Schweitz, J.A. High-sensitivity surface micromachined structures for internal stress and stress gradient evaluation. J. Micromech. Microeng. 1997, 7, 30–36.
[20]
Yu, A.B.; Liu, A.Q.; Oberhammer, J.; Zhang, Q.X.; Hosseini, H.M. Characterization and optimization of dry releasing for the fabrication of RF MEMS capacitive switches. J. Micromechan. Microeng. 2007, 17, 2024–2030.
[21]
Chinthakindi, A.K.; Kohl, P.A. Electrostatic actuators with intrinsic stress gradient I. materials and structures. J. Electrochem. Soc. 2002, 149, 139–145.
[22]
Chen, K.S. Techniques in residual stress measurement for MEMS and their applications. MEMS/NEMS 2006, doi:10.1007/0-387-25786-1_33.
[23]
CoventorWareTM. Coventor Inc. 2008. Available online: http://www.coventor.com/ (accessed on 1 February 2013).