Calibration of Results of Water Meter Test Facility Vandens skaitikli patikros renginiai ir j kalibravimo rezultataiDOI: 10.3846/113 Abstract: The results of water meter test facility calibration are presented. More than 30 test facilities are used in Lithuania nowadays. All of them are certificated for water meter of class 2 verification. The results of inter-laboratory comparison of multi-jet water meter calibration at flow rate Q = 5 m3/h are presented. Lithuanian Energy Institute was appointed as reference laboratory for the comparison. Twelve water meter verification and calibration laboratories from Lithuania participated in the ILC. The deviations from reference values were described by the normalized deviation En. Article in Lithuanian Lietuvoje yra daugiau kaip 1,5 mln. vairaus pralaidumo vandens skaitikli , kuri patikrai steigta daugiau kaip de imt laboratorij , naudojan i 32 vandens skaitikli kalibravimo renginius. Darbe pateiktos pagrindin s patikros rengini schemos ir nurodyti metrologiniai reikalavimai, keliami iems renginiams. Parodyta, kad reikiam parametr vandens sraut galima pasiekti dviem būdais – naudojant pastovaus lygio bak arba tiekiant vanden siurbliais, kai vandens talpykla būna pakankamo dyd io. Pateikti laboratorij lyginimo rezultatai, gauti kalibruojant daugiasraut alto vandens skaitikl , rodo, kad rezultat patikimum lemia ne tik rangos kokyb , bet ne ma iau svarbi yra ir laboratorijos personalo profesin kompetencija. Straipsnis lietuvi kalba
|