Successful double lumen tube insertion in a patient with unanticipated laryngeal and tracheal webKeywords: Difficult intubation , double lumen tube , laryngeal and tracheal webs Abstract: A 45-year-old female patient admitted for surgical management of carcinoma esophagus, presented with difficulty in insertion of left-sided 37 F and 35 F double lumen tube (Mallinckrodt Broncho-Cath). Fiberoptic bronchoscopy revealed a subglottic web in the larynx just below the vocal cords and a tracheal web just above the carina. Differential lung ventilation could be achieved with a 35 F internal diameter double lumen tube (Portex Blueline Endobronchial tube).
|