Power quality problems caused by termites on 138-kV underground cables Problemas de calidad de energía causados por termitas en cables subterráneos de 138kV

Keywords: Sistemas de Transmisión , Termitas , Cables Subterráneos

Full-Text   Cite this paper   Add to My Lib

Abstract:

This paper discusses problems found in the operation of underground cables in the transmission system of CEMIG, with emphasis on insulation failures caused by termites. This problem has been the source of many scheduled and nonscheduled interruptions in later years, leading to significant maintenance costs. Experience with current practices designed to detect and prevent this failure mode is described. It is argued that new procedures are needed for improved on-line, pre-failure detection. Test improvement will hopefully contribute to increase the lifetime of underground cables currently in use, as well as to reduce maintenance costs. Este artículo discute problemas encontrados en la operación de cables subterráneos en los sistemas de transmisión de CEMIG, con énfasis en las fallas de aislamiento causadas por las termitas. Problema que ha sido la fuente de muchas interrupciones programadas y no programadas en los últimos a os, llevando a significantes costos de mantenimiento. Experiencias con las prácticas corrientes planeadas para detectar y prever este modo de falla esta descrito en este trabajo. Se establece que nuevos procedimientos son necesarios para mejorar durante el funcionamiento, la detección prefalla. La mejora de pruebas se espera que contribuya tanto a aumentar la vida útil de los cables subterráneos en operación, como a reducir los costos de mantenimiento.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133