全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

An open-label, randomized, cross-over bioequivalence study of lafutidine 10 mg under fasting condition

Keywords: Liquid chromatography/tandem mass spectrometry , Lafutidine , Gastroprotective , Pharmacokinetics , Bioequivalence

Full-Text   Cite this paper   Add to My Lib

Abstract:

AIM: To assess the relative bioavailability and pharmacokinetic properties of two formulations (test and reference) of Lafutidine 10 mg.METHODS: The study was performed as an open label, randomized, two-way, two-period, two-treatment, single dose cross-over bioequivalence study, under non-fed condition to compare the pharmacokinetic profiles of the lafutidine formulation manufactured by Emcure Pharmaceuticals Ltd., India using an indigenously developed active pharmaceutical ingredient (API) and the commercially available Stogra formulation, of UCB Japan Co., Ltd., Japan. The two treatments were separated by a wash-out period of 5 d. After an overnight fasting period of 10 h, the subjects were administered either the test or the reference medication as per the randomization schedule. Blood samples were collected at intervals up to 24 h, as per the approved protocol. Concentrations of lafutidine in plasma were analyzed by a validated liquid chromatography/tandem mass spectrometry (LC/MS/MS) method, and a non-compartmental model was used for pharmacokinetic analysis. The pharmacokinetic parameters were subjected to a 4-way ANOVA accounting for sequence, subjects, period and treatment. Statistical significance was evaluated at 95% confidence level (P ≥ 0.05).RESULTS: The mean (± SD) values of the pharmacokinetic parameters (test vs reference) were Cmax (265.15 ± 49.84 ng/mL vs 246.79 ± 29.30 ng/mL, P < 0.05), Area under the curve (AUC)(0-t) (1033.13 ± 298.74 ng.h/mL vs 952.93 ± 244.07 ng.h/mL, P < 0.05), AUC(0-∞) (1047.61 ± 301.22 ng.h/mL vs 964.21 ± 246.45 ng.h/mL, P < 0.05), and t (1.92 ± 0.94 h vs 2.05 ± 1.01 h, P < 0.05). The 90% confidence intervals (CI) for the test/reference ratio of mean Cmax, AUC(0-t), and AUC(0-∞) were within the acceptable range of 80.00 to 125.00. The mean times (± SD) to attain maximal plasma concentration (tmax) of lafutidine were 0.95 ± 0.24 h vs 1.01 ± 0.29 h (P < 0.05) for the test and the reference formulations respectively. Both the formulations were well tolerated.CONCLUSION: In summary, this study has demonstrated the bioequivalence of the two formulations of lafutidine 10 mg. Hence it can be concluded that the two formulations can be used interchangeably in clinical settings.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133