Estimation of strength and stiffness of Eucalyptus grandis wood by ultrasound waves Estimativa da resistência e rigidez da madeira de Eucalyptus grandis por meio de onda ultrassonoraKeywords: Ensaio n o destrutivo , Módulo de elasticidade , Módulo de ruptura Abstract: This study aimed to evaluate the use of dynamic elastic constant obtained in non-destructive testing, as a parameter to estimate the mechanical properties of stiffness and resistance of Eucalyptus grandis. For this we used an emitter of ultrasonic waves, which had its sensitivity evaluated by comparison with the values obtained in the destructive test of static bending. The results show that the dynamic elastic constant can be used as non-destructive inference of the stiffness and resistance of Eucalyptus grandis, though with reservations, because the adjustments observed were relatively low, with R2adj. 0.25 and 0.39, respectively. doi: 10.4336/2012.pfb.32.69.109 O presente estudo objetivou avaliar o uso da constante elástica dinamica obtida no ensaio n o destrutivo, como parametro para estimativa das propriedades mecanicas de rigidez e resistência da madeira de Eucalyptus grandis. Para isto, utilizou-se um emissor de ondas ultrass nicas, o qual teve sua sensibilidade avaliada através da compara o com os valores obtidos no ensaio destrutivo de flex o estática. Os resultados evidenciam que a constante elástica dinamica pode ser utilizada para inferência n o destrutiva da rigidez e resistência da madeira de Eucalyptus grandis, entretanto com ressalvas, pois os ajustes observados foram relativamente baixos, com R2aj. de 0,25 e 0,39, respectivamente. doi: 10.4336/2012.pfb.32.69.109
|