Determining of electron temperature profile on the cross section of a Tokamak, using ECE techniqueKeywords: IR-T1 Tokamak , electron cyclotron emission , electron temperature Abstract: In this paper we have used plasma electron cyclotron emissions at the second harmonic frequency of extraordinary mode to determine the temperature profile of the plasma produced in IR-T1 Tokamak. The emissions obtained at different frequencies by a 5-channel heterodyne receiver, have been analyzed to determine the spatial variation of the electron temperature on the plasma cross section. The results have been also used to show the three-dimensional time evolution of the temperature profile during the period of confinement.
|