The safe insertion of peripheral intravenous catheters: a mixed methods descriptive study of the availability of the equipment neededKeywords: Cannulation, Patient safety, Equipment, Care bundles, Hospital acquired bacteraemia, Systems reliability Abstract: We studied 350 peripheral cannula insertions in three NHS hospital organisations across the UK. Staff inserting cannulae were asked to report details of all equipment problems. Key staff were then interviewed to identify the causes of problems with equipment availability, using semi-structured qualitative interviews and a standard coding frame.47 equipment problems were recorded during 46 of 350 cannulations, corresponding to a reliability of 87%, or 94% if problems with sharps disposal were excluded. Overall reliability was similar in all three organisations, but the types of problem varied. Interviews revealed a variety of causes including issues associated with purchasing policies, storage facilities, and lack of teamwork and communication in relation to reordering. The many human factors related to the supply chain were highlighted. Often staff had adopted work-arounds to deal with these problems.Overall, 87% of cannulations had the correct and functional equipment available. Different problems were identified in different organisations, suggesting that each had resolved some issues. Supply chain management principles may be useful to support best practice in care bundle delivery.
|