PIER Letters 2012
A Calibration Procedure for Two-Port Vna with Three Measurement Channels Based on T-MatrixAbstract: A simplified calibration procedure using T-matrix concept is presented for two-port vector network analyzer (VNA) with three measurement channels. Compared with Short-Open-Load-Thru (SOLT) calibration method based on 10-term error model where 10 error terms must be solved and saved at each frequency, the proposed method need define fewer characteristic variables. Moreover, a length-unknown 50Ω line can be used instead of a random single-port standard, for example, substituting Load standard with 50Ω line in SOLT calibration procedure. Via the simplified calibration procedure, the scattering parameters of a two-port device under test (DUT) can be finally obtained. Experimental verification is carried out, and good agreement is observed.
|