全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
Sensors  2010 

Performance Evaluation of an Infrared Thermocouple

DOI: 10.3390/s101110081

Keywords: infrared thermocouple, thermometer, calibration equation, leaf temperature

Full-Text   Cite this paper   Add to My Lib

Abstract:

The measurement of the leaf temperature of forests or agricultural plants is an important technique for the monitoring of the physiological state of crops. The infrared thermometer is a convenient device due to its fast response and nondestructive measurement technique. Nowadays, a novel infrared thermocouple, developed with the same measurement principle of the infrared thermometer but using a different detector, has been commercialized for non-contact temperature measurement. The performances of two-kinds of infrared thermocouples were evaluated in this study. The standard temperature was maintained by a temperature calibrator and a special black cavity device. The results indicated that both types of infrared thermocouples had good precision. The error distribution ranged from ?1.8?°C to 18?°C as the reading values served as the true values. Within the range from 13?°C to 37?°C, the adequate calibration equations were the high-order polynomial equations. Within the narrower range from 20?°C to 35?°C, the adequate equation was a linear equation for one sensor and a two-order polynomial equation for the other sensor. The accuracy of the two kinds of infrared thermocouple was improved by nearly 0.4?°C with the calibration equations. These devices could serve as mobile monitoring tools for in situ and real time routine estimation of leaf temperatures.

References

[1]  Ehret, DL; Lau, A; Bittman, S; Lin, W; Shelford, T. Automated monitoring of greenhouse crops. Agronomie?2001, 21, 403–414.
[2]  Jones, HG. Use of infrared thermometry for estimation of stomatal conductance as a possible aid to irrigation scheduling. Agric. Forest Meteorol?1999, 95, 139–149.
[3]  Kumar, PV; Ramakrishna, YS; Rao, BVR; Khandgonda, IR; Viictor, US; Srivastava, NN; Rao, GGSN. Assessment of plant-extractable soil water in castor beans (Ricinus communis L.) using infrared thermometry. Agr. Water Manage?1999, 39, 69–83.
[4]  Gontia, NK; Tiwari, KN. Development of crop water stress index of wheat crop for scheduling irrigation using infrared thermometry. Agr. Water Manage?2008, 95, 1144–1152.
[5]  Amiro, BD; Thurtell, GW; Gillespie, TJ. A small infrared thermometer for measuring leaf temperature in leaf chambers. J. Exp. Bot?1983, 34, 1569–1576.
[6]  Rapier, CB; Michael, KJ. The calibration of a small, low-cost thermal infrared radiometer. Remote Sens. Environ?1996, 56, 97–103.
[7]  Kalma, JD; Alksnis, H. Calibration of small infra-red surface temperature transducers. Agric. Forest Meteorol?1988, 43, 93–98.
[8]  Bugbee, B; Droter, M; Monje, O; Tanner, B. Evaluation and modification of commercial infra-red transducers for leaf temperature measurement. Adv. Space Res?1998, 10, 1425–1434.
[9]  Baker, JM; Noman, JM; Kano, A. A new approach to infrared thermometry. Agric. Forest Meteorol?2001, 108, 281–292.
[10]  Savage, MJ; Heilman, JL. Infrared calibration of net radiometers and infrared thermometers. Agric. Forest Meteorol?2009, 149, 1279–1293.
[11]  OMEGA Eng. Inc. Principles of Infrared Thermocouples. OMEGA Eng. Inc: Connecticut, Stamford, CT, USA, 2009. www.omega.com/temperature/Z/pdf/Z076-080.pdf.
[12]  Chen, C. Evaluation of measurement uncertainty for thermometers with calibration equations. Accred. Qual. Assur?2006, 11, 75–82.
[13]  Grientschnig, D. Relationship between prediction errors of inverse and classical calibration. Fresenius J. Anal. Chem?2002, 367, 497–498.
[14]  Mahan, JR; Yeater, KM. Agricultural applications of a low-cost infrared thermometer. Comput. Electron. Agric?2008, 64, 262–267.
[15]  Saunders, P. Calibration of low-temperature infrared thermometers. In MSL Technical Guide 22; Measurement Standards Laboratory of New Zealand: New Zealand, 2009.
[16]  Myers, RH. Classical and Modern Regression with Application; PWS and Kent Publisher: Boston, MA, USA, 1986.
[17]  Schilz, J. Remote Temperature Measurement with Perkinelmer Thermopile Sensors: A Practical Guide to Quantitative Results; PerkinElmer Optoelectronics Gmbh: Wiesbaden, Gemany, 2001.
[18]  Abraham, N; Hema, PS; Sarithe, EK; Subramannian, S. Irrigation automation based on soil electrical conductivity and leaf temperature. Agr. Water Manage?2006, 45, 145–157.
[19]  Ai-Faraj, A; Meyer, GE; Horst, GL. A crop water stress index for tall fescue Festuca arundinacea Schreb. irrigation decision-making—A traditional method. Comput. Electron. Agric?2001, 31, 107–124.
[20]  Anthura, bv. Cultivation Tip, 2009. Available online: http://www.anthura.nl/page/en/Cultivation/cultivation-tip (accessed on 8 November 2010).

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133