Sensors  2012 

Development of a Plastic-Based Microfluidic Immunosensor Chip for Detection of H1N1 Influenza

DOI: 10.3390/s120810810

Keywords: immunosensor, H1N1 influenza, microfluidics, plastic chip

Full-Text   Cite this paper   Add to My Lib

Abstract:

Lab-on-a-chip can provide convenient and accurate diagnosis tools. In this paper, a plastic-based microfluidic immunosensor chip for the diagnosis of swine flu (H1N1) was developed by immobilizing hemagglutinin antigen on a gold surface using a genetically engineered polypeptide. A fluorescent dye-labeled antibody (Ab) was used for quantifying the concentration of Ab in the immunosensor chip using a fluorescent technique. For increasing the detection efficiency and reducing the errors, three chambers and three microchannels were designed in one microfluidic chip. This protocol could be applied to the diagnosis of other infectious diseases in a microfluidic device.

References

[1]  Kao, L.T.; Shankar, L.; Kang, T.G.; Zhang, G.; Taym, G.K.I.; Rafei, S.R.M.; Lee, C.W.H. Multiplexed detection and differentiation of the DNA strains for influenza A (H1N1 2009) using a silicon-based microfluidic system. Biosens. Bioelectron 2011, 26, 2006–2011.
[2]  Ferguson, B.S.; Buchsbaum, S.F.; Wu, T.; Hsieh, K.; Xiao, Y.; Sun, R.; Soh, H.T. Genetic analysis of H1N1 influenza virus from throat swab samples in a microfluidic system for point-of-care diagnostics. J. Am. Chem. Soc. 2011, 133, 9129–9135.
[3]  Xu, G.; Hsieh, T.; Lee, D.Y.S.; Ali, E.M.; Xie, H.; Looi, X.L.; Koay, E.S.-C.; Li, M.; Ying, Y.A. A self-contained all-in-one cartridge for sample preparation and real-time PCR in rapid influenza diagnosis. Lab Chip. 2010, 10, 3103–3111.
[4]  Poon, L.L.; Chan, K.H.; Smith, G.J.; Leung, C.S.; Guan, Y.; Yuen, K.Y.; Peiris, J.S. Molecular detection of a novel human influenza (H1N1) of pandemic potential by conventional and real-time quantitative RT-PCR assays. Clin. Chem. 2009, 55, 1555–1558.
[5]  Darain, F.; Yager, P.; Gan, K.L.; Tjin, W.C. On-chip detection of myoglobin based on fluorescence. Biosens. Bioelectron 2009, 24, 1744–1750.
[6]  Henares, T.G.; Mizutani, F.; Hisamoto, H. Current development in microfluidic immunosensing chip. Anal. Chim. Acta. 2008, 611, 17–30.
[7]  Zhao, J.; Zhang, Q.; Yang, H.; Tu, Y. Electrophoretic separation of neurotransmitters on a polystyrene nano-sphere/polystyrene sulphonate coated poly(dimethylsiloxane) microchannel. Biomicrofluidics 2011, 5, 034104–034109.
[8]  Nunes, P.S.; Ohlsson, P.D.; Ordeig, O.; Kutter, J.P. Cyclic olefin polymers: Emerging materials for lab-on-a-chip applications. Microfluid. Nanofluid 2010, 9, 145–161.
[9]  Ko, S.; Park, T.J.; Kim, H.; Kim, J.; Cho, Y. Directed self-assembly of gold binding polypeptide-protein: A fusion proteins for development of gold nanoparticle-based SPR immunosensors. Biosens. Bioelectron 2009, 24, 2592–2597.
[10]  Skottrup, P.D.; Nicolaisen, M.; Justesen, A.F. Towards on-site pathogen detection using antibody-based sensors. Biosens. Bioelectron 2008, 24, 339–348.
[11]  Brown, S. Metal-recongnition by repeating polypeptide. Nat. Biotechnol. 1997, 15, 269–272.
[12]  Park, T.J.; Lee, S.Y.; Lee, S.J.; Park, J.P.; Yang, K.S.; Lee, K.; Park, S.K.J.B.; Kim, T.; Kim, S.K.; et al. Protein nanopatterns and biosensors using gold binding polypeptide as a fusion partner. Anal. Chem. 2006, 78, 7197–7205.
[13]  Huh, Y.S.; Park, T.J.; Lee, E.Z.; Hong, W.H.; Lee, S.Y. Development of a fully integrated microfluidic system for sensing infectious viral disease. Electrophoresis 2008, 29, 2960–2969.
[14]  Park, T.J.; Hyun, M.S.; Lee, H.J.; Lee, S.Y.; Ko, S. A self-assembled fusion protein-based surface plasmon resonance biosensor for rapid diagnosis of severe acute respiratory syndrome. Talanta 2009, 79, 295–301.
[15]  Yang, M.H.; Choi, B.G.; Park, H.; Hong, W.H.; Lee, S.Y.; Park, T.J. Development of the glucose biosensor using advanced electrode modified by nanohybrid composing chemically modified graphene and ionic liquid. Electroanalysis 2010, 22, 1223–1228.
[16]  Zeng, S.; Kim, D.-K.; Park, T.J.; Lee, S.J.; Lee, S.Y. Label-free optical diagnosis of hepaptitis b virus with genetically engineered fusion proteins. Talanta 2010, 82, 803–809.
[17]  Oh, H.J.; Park, J.H.; Lee, S.J.; Kim, B.I.; Song, Y.S.; Youn, J.R. Sustainable fabrication of micro-structured lab-on-a-chip. Lab Chip 2011, 11, 3999–4005.
[18]  Lee, K.G.; Wi, R.; Park, T.J.; Yoon, S.H.; Lee, J.B.; Lee, S.J.; Kim, D.H. Synthesis and characterization of gold-deposited red, green and blue fluorescent silica nanoparticles for biosensing application. Chem. Commun. 2010, 46, 6374–6376.
[19]  Lahiri, J.; Isaacs, L.; Tien, J.; Whitesides, G.M. A strategy for the generation of surfaces presenting ligands for studies of binding based on an active ester as a common reactive intermediate: a surface plasmon resonance study. Anal. Chem. 1999, 71, 777–790.
[20]  Subramanian, A.; Irudayaraj, J.; Ryan, T. Mono and dithiol surfaces on surface plasmon resonance biosensors for detection of staphylococcus aureus. Sensor Actuator B Chem. 2006, 114, 192–198.