Sensors  2012 

Numerical Investigations on Electric Field Characteristics with Respect to Capacitive Detection of Free-Flying Droplets

DOI: 10.3390/s120810550

Keywords: droplet sensor, CFD simulation, capacitive measurement, multi physics simulation, non-contact sensor, online process control

Full-Text   Cite this paper   Add to My Lib

Abstract:

In this paper a multi-disciplinary simulation of a capacitive droplet sensor based on an open plate capacitor as transducing element is presented. The numerical simulations are based on the finite volume method (FVM), including calculations of an electric field which changes according to the presence of a liquid droplet. The volume of fluid (VOF) method is applied for the simulation of the ejection process of a liquid droplet out of a dispenser nozzle. The simulations were realised using the computational fluid dynamic (CFD) software CFD ACE+. The investigated capacitive sensing principle enables to determine the volume of a micro droplet passing the sensor capacitor due to the induced change in capacity. It could be found that single droplets in the considered volume range of 5 nL < Vdrop < 100 nL lead to a linear change of the capacity up to ΔQ < 30 fC. The sensitivity of the focused capacitor geometry was evaluated to be Si = 0.3 fC/nL. The simulation results are validated by experiments which exhibit good agreement.

References

[1]  Engelmann, M.; Fekete, A.; Gebefügi, I.; Schmitt-Kopplin, P. The dosage of small volumes for chromatographic quantifications using drop-on-demand dispenser system. Anal. Bioanal. Chem. 2007, 388, 1109–1116.
[2]  Taylor, P.B.; Ashman, S.; Baddeley, S.M.; Bartram, S.L.; Battle, C.D.; Bond, B.C.; Clements, Y.M.; Gaul, N.J.; Elliot McAllister, W.; Mostacero, J.A.; et al. A standard operation procedure for assessing liquid handler performance in high-throughput screening. J. Biomol. Screen. 2002, 7, 544–569.
[3]  Tisone, T.C.; Citeau, H.; McIntosh, B. In-line processing trends for lateral-flow immunoassay manufacturing. IVD Technol. 2007, 13, 37–41.
[4]  Thurow, K.; Krüger, T.; Stoll, N. An optical approach for the determination of droplet volumes in nanoliterdispensing. J. Autom. Methods Manag. Chem. 2009, doi:10.1155/2009/198732.
[5]  Mason, B.J.; Ramanadham, R. A photoelectric raindrop spectrometer. Q. J. R. Meteorol. Soc. 1953, 79, 490–495.
[6]  Tr?ndle, J.; Ernst, A.; Streule, W.; Zengerle, R.; Koltay, P. Non-contact optical sensor to detect free flying droplets in the nanolitre range. Sens. Actuators A 2010, 158, 254–262.
[7]  Winn, W.P. An electrostatic theory for instruments which measure the radii of water drops by detecting a change in capacity due to the presence of a drop. J. Appl. Meteor. 1968, 7, 929–937.
[8]  Ernst, A.; Lin, J.; Vondenbusch, B.; Zengerle, R.; Koltay, P. Noncontact determination of velocity and volume of nanoliter droplets on the fly. IEEE Sens. J. 2011, 11, 1736–1742.
[9]  Streule, W.; Lindemann, T.; Birkle, G.; Zengerle, R.; Koltay, P. PipeJet: A simple disposable dispenser for the nanoliter- and microliter range. JALA 2004, 9, 300–306.
[10]  Geissler, P.L.; Dellago, C.; Chandler, D.; Hutter, J.; Parrinello, M. Autoionization in liquid water. Science 2001, 291, 2121–2124.
[11]  Anderson, J.D. Computational Fluid Dynamics—The Basics with Applications; McGraw-Hill: New York, NY, USA, 1995.
[12]  Hirt, C.W.; Nicholson, B.D. Volume of fluid (VOF) method for the dynamics of free boundaries. J. Comp. Phys. 1981, 39, 201–225.
[13]  Rider, J.W.; Kothe, D.B. Reconstruction volume tracking. J. Comp. Phys. 1998, 141, 112–152.
[14]  Fang, C.; Hidrovo, C.; Wang, F.-M.; Eaton, J.; Goodson, K. 3-D numerical simulation of contact angle hysteresis for microscale two phase flow. Int. J. Multiph. Flow 2008, 34, 690–705.
[15]  Brackbill, J.U.; Kothe, D.B.; Zemach, C. A continuum method for modeling surface tension. J. Comput. Phys. 1992, 100, 335–354.
[16]  ESI-Group. 2010. Available online: http://www.esi-group.com (accessed on 29 June 2010).

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133