This study reports an integrated microfluidic perfusion cell culture system consisting of a microfluidic cell culture chip, and an indium tin oxide (ITO) glass-based microheater chip for micro-scale perfusion cell culture, and its real-time microscopic observation. The system features in maintaining both uniform, and stable chemical or thermal environments, and providing a backflow-free medium pumping, and a precise thermal control functions. In this work, the performance of the medium pumping scheme, and the ITO glass microheater were experimentally evaluated. Results show that the medium delivery mechanism was able to provide pumping rates ranging from 15.4 to 120.0?μL·min?1. In addition, numerical simulation and experimental evaluation were conducted to verify that the ITO glass microheater was capable of providing a spatially uniform thermal environment, and precise temperature control with a mild variation of ±0.3?°C. Furthermore, a perfusion cell culture was successfully demonstrated, showing the cultured cells were kept at high cell viability of 95 ± 2%. In the process, the cultured chondrocytes can be clearly visualized microscopically. As a whole, the proposed cell culture system has paved an alternative route to carry out real-time microscopic observation of biological cells in a simple, user-friendly, and low cost manner.
References
[1]
Xu, X; Urban, JPG; Browning, JA; Tirlapur, U; Wilkins, RJ; Wu, MH; Cui, Z; Cui, ZF. Influences of buffer systems on chondrocyte growth during long-term culture in alginate. Osteoarthritis Cartilage 2007, 15, 396–402.
[2]
Wu, MH; Urban, JPG; Cui, ZF; Cui, Z; Xu, X. Effect of extracellular pH on matrix synthesis by chondrocytes in 3D agarose gel. Biotechnol. Prog 2007, 23, 430–434.
[3]
Wu, MH; Huang, SB; Cui, ZF; Cui, Z; Lee, GB. Development of perfusion-based micro 3-D cell culture platform and its application for high throughput drug testing. Sens. Actuat. B 2008, 129, 231–240.
[4]
Cui, ZF; Xu, X; Trainor, N; Triffitt, JT; Urban, JP; Tirlapur, UK. Application of multiple parallel perfused microbioreactors and three-dimensional stem cell culture for toxicity testing. Toxicol. In Vitro 2007, 21, 1318–1324.
[5]
Wu, MH; Kuo, CY. Application of high throughput perfusion micro 3-D cell culture platform for the precise study of cellular responses to extracellular conditions-effect of serum concentrations on the physiology of articular chondrocytes. Biomed. Microdevices 2011, 13, 131–141.
[6]
Sittinger, M; Schultz, O; Keyszer, G; Minuth, WW; Burmester, GR. Artificial tissues in perfusion culture. Int. J. Artif. Organs 1997, 20, 57–62.
[7]
Vickerman, V; Blundo, J; Chung, S; Kamm, RD. Design, fabrication, implementation of a novel multi parameter control microfluidic platform for three-dimensional cell culture and real-time imaging. Lab Chip 2008, 8, 1468–1477.
[8]
Chau, L; Doran, M; Cooper-White, J. A novel multishear microdevice for the studying cell mechanics. Lab Chip 2009, 9, 1897–1902.
Wu, MH; Huang, SB; Lee, GB. Microfluidic cell culture systems for drug research. Lab Chip 2010, 10, 939–956.
[11]
Ng, CP; Pun, SH. A Perfusable 3D cell–matrix tissue culture chamber for in situ evaluation of nanoparticle vehicle penetration and transport. Biotechnol. Bioeng 2008, 99, 1490–1501.
Wu, MH; Huang, SB; Cui, ZF; Cui, Z; Lee, GB. A high throughput perfusion-based microbioreactor platform integrated with pneumatic micropumps for three-dimensional cell culture. Biomed. Microdevices 2008, 10, 309–319.
[17]
Yoon, SK; Ahn, YH; Jeong, MH. Effect of culture temperature on follicle-stimulating hormone production by Chinese hamster ovary cells in a perfusion bioreactor. Appl. Microbiol. Biotechnol 2007, 76, 83–89.
[18]
Chong, SL; Mou, DG; Ali, AM; Lim, SH; Tey, BT. Cell growth, cell cycle progress and antibody production in hybridoma cells cultured under mild hypothermic conditions. Hybridoma 2008, 27, 107–111.
[19]
Chen, PC; Nikitopoullos, DE; Soper, SA; Murphy, MC. Temperature distribution effects on micro-CFPCR performance. Biomed. Microdevices 2008, 10, 141–152.
[20]
Lee, WC; Lien, KY; Lee, GB; Lei, HY. An integrated microfluidic system using magnetic beads for virus detection. Diagn. Microbiol. Infect. Dis 2008, 60, 51–58.
[21]
Huang, CW; Lee, GB. A microfluidic system for automatic cell culture. J. Micromech. Microeng 2007, 17, 1266–1274.
[22]
Lin, JL; Wu, MH; Kuo, CY; Lee, KD; Shen, YL. Application of indium tin oxide (ITO)-based microheater chip with uniform thermal distribution for perfusion cell culture outside a cell incubator. Biomed. Microdevices 2010, 12, 389–398.
[23]
Huang, SB; Wu, MH; Lee, GB. Microfluidic device utilizing pneumatic micro-vibrators to generate alginate microbeads for microencapsulation of cells. Sens. Actuat. B 2010, 147, 755–764.
[24]
Wu, MH; Urban, JPG; Cui, Z; Cui, ZF. Development of PDMS microbioreactor with well-defined and homogenous culture environment for chondrocyte 3-D culture. Biomed. Microdevices 2006, 8, 331–340.
[25]
Huang, SB; Wu, MH; Cui, ZF; Cui, Z; Lee, GB. A membrane-based serpentine-shape pneumatic micropump with pumping performance modulated by fluidic resistance. J Micromech Microeng 2008, 18, 045008.1–045008.12.
[26]
Huang, CW; Huang, SB; Lee, GB. Pneumatic micropumps with serially connected chambers. J. Micromech. Microeng 2006, 16, 2265–2272.
[27]
Yang, YN; Hsiung, SK; Lee, GB. A pneumatic micropump incorporated with a normally closed valve capable of generating a high pumping rate and a high back pressure. Microfluid. Nanofluid 2009, 6, 823–833.
[28]
El-Ali, J; Perch-Nielsen, IR; Poulsen, CR; Bang, DD; Telleman, P; Wolff, A. Simulation and experimental validation of a SU-8 based PCR thermocycler chip with integrated heaters and temperature sensor. Sens. Actuat. A 2004, 110, 3–10.