全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
Sensors  2010 

Development of a Fully Automated Flow Injection Analyzer Implementing Bioluminescent Biosensors for Water Toxicity Assessment

DOI: 10.3390/s100807089

Keywords: Vibrio fischeri, toxicity, flow injection

Full-Text   Cite this paper   Add to My Lib

Abstract:

This paper describes the development of an automated Flow Injection analyzer for water toxicity assessment. The analyzer is validated by assessing the toxicity of heavy metal (Pb2+, Hg2+ and Cu2+) solutions. One hundred μL of a Vibrio fischeri suspension are injected in a carrier solution containing different heavy metal concentrations. Biosensor cells are mixed with the toxic carrier solution in the mixing coil on the way to the detector. Response registered is % inhibition of biosensor bioluminescence due to heavy metal toxicity in comparison to that resulting by injecting the Vibrio fischeri suspension in deionised water. Carrier solutions of mercury showed higher toxicity than the other heavy metals, whereas all metals show concentration related levels of toxicity. The biosensor’s response to carrier solutions of different pHs was tested. Vibrio fischeri’s bioluminescence is promoted in the pH 5–10 range. Experiments indicate that the whole cell biosensor, as applied in the automated fluidic system, responds to various toxic solutions.

References

[1]  Dewhurst, RE; Wheeler, JR; Chummun, KS; Mather, JD; Callaghan, A; Crane, M. The comparison of rapid bioassays for the assessment of urban groundwater quality. Chemosphere?2002, 47, 547–554, doi:10.1016/S0045-6535(02)00060-7. 11996130
[2]  Forget, G; Sanchez-Bain, A; Arkhipchuk, V; Beauregard, T; Blaise, C; Castillo, G; Castillo, LE; Diaz-Baez, MC; Pica-Granados, Y; Ronco, A; Srivastava, RC; Dutka, BJ. Preliminary data of a single-blind, multicountry trial of six bioassays for water toxicity monitoring. Environ. Toxicol?2000, 15, 362–369, doi:10.1002/1522-7278(2000)15:5<362::AID-TOX2>3.0.CO;2-Q.
[3]  Deryabin, DG; Karimov, IF. Simultaneous evaluation of chemiluminescence and bioluminescence in a phagocytic system. Bull. Exp. Biol. Med-Engl. Tr?2009, 147, 349–352, doi:10.1007/s10517-009-0506-2.
[4]  Farre, M; Barcelo, D. Toxicity testing of wastewater and sewage sludge by biosensors, bioassays and chemical analysis. Trac-Trend. Anal. Chem?2003, 22, 299–310, doi:10.1016/S0165-9936(03)00504-1.
[5]  El-Alawi, YS; Huang, XD; Dixon, DG; Greenberg, BM. Quantitative structure-activity relationship for the photoinduced toxicity of polycyclic aromatic hydrocarbons to the luminescent bacteria Vibrio fischeri. Environ. Toxicol. Chem?2002, 21, 2225–2232. 12371502
[6]  D'Souza, SF. Microbial biosensors. Biosens. Bioelectron?2001, 16, 337–353, doi:10.1016/S0956-5663(01)00125-7. 11672648
[7]  Divritsioti, MH; Karalemas, ID; Georgiou, CA; Papastathopoulos, DS. Flow Injection analysis system for l-lysine estimation in foodstuffs using a biosensor based on lysine oxidase immobilization on a gold-poly (m-phenylenediamine) electrode. Anal. Lett?2003, 36, 1939–1963, doi:10.1081/AL-120023623.
[8]  Liu, XM; Germaine, KJ; Ruan, D; Dowling, D. Whole cell fluorescent biosensors for bioavailability and biodegradation of polychlorinated biphenyls. Sensors?2010, 10, 1377–1398, doi:10.3390/s100201377. 22205873
[9]  Beyersdorf-Radeck, B; Riedel, K; Karlson, U; Bachmann, TT; Schmid, RD. Screening of xenobiotic compounds degrading microorganisms using biosensor techniques. Microbiol. Res?1998, 153, 239–245, doi:10.1016/S0944-5013(98)80006-2. 9880928
[10]  Petanen, T; Romantschuk, M. Use of bioluminescent bacterial sensors as an alternative method for measuring heavy metals in soil extracts. Anal. Chim. Acta?2002, 456, 55–61, doi:10.1016/S0003-2670(01)00963-1.
[11]  Liu, Q; Cai, H; Xiao, L; Li, R; Yang, M; Wang, P. Embryonic stem cells biosensor and its application in drug analysis and toxin detection. IEEE Sensors J?2007, 7, 1625–1631, doi:10.1109/JSEN.2007.908439.
[12]  Peters, M; Vaillancourt, F; Xeroux, M; Valiquette, M; Scott, C. Comparing label-free biosensors for pharmacological screening with cell-based functional assays. Assay Drug Dev. Technol?2010, 8, 219–227, doi:10.1089/adt.2009.0232. 20085460
[13]  Baeumner, AJ. Biosensors for environmental pollutants and food contaminants. Anal. Bioanal. Chem?2003, 377, 434–445, doi:10.1007/s00216-003-2158-9. 12920503
[14]  Melidis, P; Vaiopoulou, E; Aivasidis, A. Development and implementation of microbial sensors for efficient process control in wastewater treatment plants. Bioprocess Biosyst. Eng?2008, 31, 277–282, doi:10.1007/s00449-007-0192-2. 18193294
[15]  Minioti, KS; Georgiou, CA. Comparison of different tests used in mapping the Greek virgin olive oil production for the determination of its total antioxidant capacity. Grasas Aceites?2010, 61, 45–51, doi:10.3989/gya.010508.
[16]  Mimendia, A; Legin, A; Mercoci, A; del Valle, M. Use of sequential injection analysis to construct a potentiometric electronic tongue: Application to the multidetermination of heavy metals. Sens Actuat B-Chem?2010, 420–426.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133