Sensors  2010 

Detection of Cartilage Oligomeric Matrix Protein Using a Quartz Crystal Microbalance

DOI: 10.3390/s101211633

Keywords: immunosensor, quartz crystal microbalance (QCM), cartilage oligomeric matrix protein (COMP), urinary biomarker

Full-Text   Cite this paper   Add to My Lib

Abstract:

Current methods for diagnosing early stage osteoarthritis (OA) based on the magnetic resonance imaging and enzyme-linked immunosorbent assay methods are specific, but require specialized laboratory facilities and highly trained personal to obtain a definitive result. In this work, a user friendly and non-invasive quartz crystal microbalance (QCM) immunosensor method has been developed to detect Cartilage Oligomeric Matrix Protein (COMP) for early stage OA diagnosis. This QCM immunosensor was fabricated to immobilize COMP antibodies utilizing the self-assembled monolayer technique. The surface properties of the immunosensor were characterized by its FTIR and electrochemical impedance spectra (EIS). The feasibility study was based on urine samples obtained from 41 volunteers. Experiments were carried out in a flow system and the reproducibility of the electrodes was evaluated by the impedance measured by EIS. Its potential dynamically monitored the immunoreaction processes and could increase the efficiency and sensitivity of COMP detection in laboratory-cultured preparations and clinical samples. The frequency responses of the QCM immunosensor changed from 6 kHz when testing 50 ng/mL COMP concentration. The linear regression equation of frequency shift and COMP concentration was determined as: y = 0.0872 x + 1.2138 (R2 = 0.9957). The COMP in urine was also determined by both QCM and EIS for comparison. A highly sensitive, user friendly and cost effective analytical method for the early stage OA diagnosis has thus been successfully developed.

References

[1]  Pollard, TCB; Gwilym, SE; Carr, AJ. The assessment of early osteoarthritis. J Bone Joint Surg 2008, 90, 411–421.
[2]  Bruyere, O; Collette, JH; Ethgen, O; Rovati, LC; Giacovelli, G; Henrotin, YE; Seidel, L; Reginster, JY. Biochemical markers of bone and cartilage remodeling in prediction of longterm progression of knee osteoarthritis. J Rheumatol 2003, 30, 1043–1050.
[3]  Misumi, K; Vilim, V; Clegg, PD; Thompson, CC; Carter, SD. Measurement of cartilage oligomeric matrix protein (COMP) in normal and diseased equine synovial fluids. Osteoarthritis Cartilage 2001, 9, 119–127.
[4]  Zaucke, F; Dinser, R; Maurer, P; Paulsson, M. Cartilage oligomeric matrix protein (COMP) and collagen IX are sensitive markers for the differentiation state of articular primary chondrocytes. Biochem J 2001, 358, 17–24.
[5]  Misumi, K; Vilim, V; Clegg, PD; Thompson, CC; Carter, SC. Measurement of cartilage oligomeric matrix protein (COMP) in normal and diseased equine synovial fluids. Osteoarthritis Cartilage 2001, 9, 119–127.
[6]  Vilim, V; Voburka, Z; Vytasek, R; Senolt, L; Tchetverikov, I; Kraus, VB; Pavelka, K. Monoclonal antibodies to human cartilage oligomeric matrix protein: epitope mapping and characterization of sandwich ELISA. Clin Chim Acta 2003, 328, 59–69.
[7]  Critchley, P; Dimmock, NJ. Binding of an influenza a virus to a neomembrane measured by surface plasmon resonance. Bioorg Med Chem 2004, 12, 2773–2780.
[8]  Hardy, SA; Dimmock, NJ. Valency of antibody binding to enveloped virus particles as determined by surface plasmon resonance. J Virol 2003, 77, 1649–1652.
[9]  Mecea, VM. From quartz crystal microbalance to fundamental principles of mass measurements. Anal Lett 2005, 38, 753–767.
[10]  Eun, AJ; Huang, L; Chew, FT; Li, SF; Wong, SM. Detection of two orchid viruses using quartz crystal microbalance immunosensors. J Virol Meth 2002, 99, 71–79.
[11]  Wu, TZ; Su, CC; Chen, LK; Yang, HH; Tai, DF; Peng, KC. Piezoelectric immunochip for the detection of dengue fever in viremia phase. Biosens Bioelectron 2005, 21, 689–695.
[12]  Zhou, X; Liu, L; Hu, M; Wang, L; Hu, J. Detection of hepatitis B virus by piezoelectric biosensor. J Pharm Biomed Anal 2002, 27, 341–345.
[13]  Sauerbrey, G. Use of a quartz vibrator for weighing thin layers on a microbalance. Z Phys 1959, 155, 206–222.
[14]  Kanazawa, KK; Gordon, JG. Frequency of a quartz microbalance in contact with liquid. Anal Chem 1985, 57, 1770–1771.
[15]  Lee, YG; Chang, KS. Application of a flow type quartz crystal microbalance immunosensor for real time determination of cattle bovine ephemeral fever virus in liquid. Talanta 2005, 65, 1335–1342.
[16]  Park, J; Kurosawa, S; Aizawa, H; Wakida, S; Yamada, S; Ishihara, K. Comparison of stabilizing effect of stabilizers for immobilized antibodies on QCM immunosensors. Sens Actuat B Chem 2003, 91, 158–162.
[17]  Hewa, TMP; Tannock, GA; Mainwaring, DE; Harrison, S; Fecondo, JV. The detection of influenza A and B viruses in clinical specimens using a quartz crystal microbalance. J Virol Meth 2009, 162, 14–21.
[18]  Zeng, H; Wang, H; Chen, FP; Xin, HY; Wang, GP; Xiao, L; Song, K; Wu, DS; He, Q; Shen, GL. Development of quartz-crystal-microbalance-based immunosensor array for clinical immunophenotyping of acute leukemias. Anal Chem 2006, 351, 69–76.
[19]  Kurosawa, S; Park, JW; Aizawa, H; Wakida, S; Tao, H; Ishihara, K. Quartz crystal microbalance immunosensors for environmental monitoring. Biosens Bioelectron 2006, 22, 473–481.
[20]  Human Cartilage Oligomeric Matrix Protein ELISA. Available online: http://www.progeninc.co.kr/pdf/Cartilage%20Oligimeric%20Matrix%20Protein%20Human%20ELISA.pdf (accessed on 12 December 2010).