全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
Sensors  2010 

Diode Laser Detection of Greenhouse Gases in the Near-Infrared Region by Wavelength Modulation Spectroscopy: Pressure Dependence of the Detection Sensitivity

DOI: 10.3390/s100504686

Keywords: gas sensing, wavelength modulation spectroscopy, near-infrared absorption spectroscopy

Full-Text   Cite this paper   Add to My Lib

Abstract:

We have investigated the pressure dependence of the detection sensitivity of CO2, N2O and CH4 using wavelength modulation spectroscopy (WMS) with distributed feed-back diode lasers in the near infrared region. The spectral line shapes and the background noise of the second harmonics (2f) detection of the WMS were analyzed theoretically. We determined the optimum pressure conditions in the detection of CO2, N2O and CH4, by taking into consideration the background noise in the WMS. At the optimum total pressure for the detection of CO2, N2O and CH4, the limits of detection in the present system were determined.

References

[1]  Richter, D.; Fried, A.; Wert, B.P.; Walega, J.G.; Tittel, F.K. Development of a tunable mid-IR difference frequency laser source for highly sensitive airborne trace gas detection. Appl. Phys. B?2002, 75, 281–288, doi:10.1007/s00340-002-0948-y. 12599397
[2]  Gianfrani, L.; Sasso, A.; Tino, G.M. Monitoring of O2 and NO2 using tunable diode lasers in the near-infrared region. Sens. Actuat. B?1997, 38, 283–285.
[3]  Uehara, K.; Yamamoto, K.; Kikugawa, T.; Yoshida, N. Isotope analysis of environmental substances by a new laser-spectroscopic method utilizing different path lengths. Sens. Actuat. B?2001, 74, 173–178, doi:10.1016/S0925-4005(00)00729-2.
[4]  Hennig, O.; Strzoda, R.; Magori, E.; Chemisky, E.; Tump, C.; Fleischer, M.; Meixner, H.; Eisele, I. Hand-held unit for simultaneous detection of methane and ethane based on NIR-absorption spectroscopy. Sens. Actuat. B?2003, 95, 151–156, doi:10.1016/S0925-4005(03)00399-X.
[5]  Katchalski, T.; Soria, S.; Teitelbaum, E.; Friesem, A.A.; Marowsky, G. Two photon fluorescence sensors based on resonant grating waveguide structures. Sens. Actuat. B?2005, 107, 121–125, doi:10.1016/j.snb.2004.07.040.
[6]  Werle, P. A Review of recent advances in semiconductor laser based gas monitors. Spectrochim. Acta A?1998, 54, 197–236, doi:10.1016/S1386-1425(97)00227-8.
[7]  Linnerud, I.; Kaspersen, P.; Jager, T. Gas monitoring in the process industry using diode laser spectroscopy. Appl. Phys. B?1998, 67, 297–305, doi:10.1007/s003400050509.
[8]  Werle, P.; Mucke, R.; D’Amato, F.; Lancai, T. Near-infrared trace-gas sensors based on room-temperature diode lasers. Appl. Phys. B?1998, 67, 307–315, doi:10.1007/s003400050510.
[9]  Crosson, E.R. A cavity ring-down analyzer for measuring atmospheric levels of methane, carbon dioxide, and water. Appl. Phys. B?2008, 92, 403–408, doi:10.1007/s00340-008-3135-y.
[10]  Ye, J.; Ma, L.S.; Hall, J.L. Ultrasensitive detections in atomic and molecular physics: demonstration in molecular overtone spectroscopy. J. Opt. Soc. Am. B?1998, 15, 6–15, doi:10.1364/JOSAB.15.000006.
[11]  Herriott, D.R.; Schulte, H.J. Folded optical delay lines. Appl. Opt?1965, 4, 883–889, doi:10.1364/AO.4.000883.
[12]  Pavone, F.S.; Inguscio, M. Frequency- and wavelength-modulation spectroscopies: Comparison of experimental methods using an AlGaAs diode laser. Appl. Phys. B?1993, 56, 118–122, doi:10.1007/BF00325250.
[13]  Cooper, D.E.; Warren, R.E. Frequency modulation spectroscopy with lead-salt diode lasers: a comparison of single-tone and two-tone techniques. Appl. Opt?1987, 26, 3726–3732, doi:10.1364/AO.26.003726. 20490130
[14]  Silver, J.A. Frequency-modulation spectroscopy for trace species detection: theory and comparison among experimental methods. Appl. Opt?1992, 31, 707–717, doi:10.1364/AO.31.000707. 20720674
[15]  Supplee, J.M.; Whittaker, E.A.; Lenth, W. Theoretical description of frequency modulation and wavelength modulation spectroscopy. Appl. Opt?1994, 33, 6294–6302, doi:10.1364/AO.33.006294. 20941160
[16]  Wilson, G.V.H. Modulation broadening of NMR and ESR line shapes. J. Appl. Phys?1963, 34, 3276–3285, doi:10.1063/1.1729177.
[17]  LI-COR Bioscience HP. Available on line: http://www.licor.com/env/Products/GasAnalyzers/li7700/7700.jsp (Access on February 2010).
[18]  Humlicek, J. Optimized computation of the Voigt and complex probability functions. J. Quant. Spectrosc. Radiat. Transfer?1982, 27, 437–444, doi:10.1016/0022-4073(82)90078-4.
[19]  Schreier, F. The Voigt and complex error function: A comparison of computational methods. J. Quant. Spectrosc. Radiat. Transfer?1992, 48, 743–762, doi:10.1016/0022-4073(92)90139-U.
[20]  Rothman, L.S.; Jacquemart, D.; Barbe, A.; Benner, D.C.; Birk, M.; Brown, L.R.; Carleer, M.R.; Chackerian, C., Jr.; Chance, K.; Coudert, L.H.; Dana, V.; Devi, V.M.; Flaud, J.-M.; Gamache, R.R.; Goldman, A.; Hartmann, J.-M.; Jucks, K.W.; Maki, A.G.; Mandin, J.-Y.; Massie, S.T.; Orphal, J.; Perrin, A.; Rinsland, C.P.; Smith, M.A.H.; Tennyson, J.; Tolchenov, R.N.; Toth, R.A.; Auwera, J.V.; Varanasi, P.; Wagner, G. The HITRAN 2004 molecular spectroscopic database. J. Quant. Spectrosc. Radiat. Transfer?2005, 96, 139–204, doi:10.1016/j.jqsrt.2004.10.008.
[21]  Reid, J.; Labrie, D. Second-harmonic detection with tunable diode lasers-Comparison of experiment and theory. Appl. Phys. B?1981, 26, 203–210, doi:10.1007/BF00692448.
[22]  Parkes, A.M.; Linsley, A.R.; Orr-Ewing, A.J. Absorption cross-sections and pressure broadening of rotational lines in the 3ν3 band of N2O determined by diode laser cavity ring-down spectroscopy. Chem. Phys. Lett?2003, 377, 439–444, doi:10.1016/S0009-2614(03)01155-2.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133