(Ⅰ+Ⅱ)MIXED MODE HYDROGEN INDUCED CRACKINGKeywords: (Ⅰ+Ⅱ)mixed,mode,hydrogen,induced,cracking Abstract: Hydrogen induced cracking(HIC)of 0.3% C,1% Cr,1% Mn,1% Si high strength steel hasbeen studied under simple mode Ⅰ,mode Ⅱ and(Ⅰ+Ⅱ)mixed mode loading conditions.Af-ter being hydrogen-charged in IN H_2SO_4 solution,the material behaved hydrogenembrittlement in all the cases studied.The threshold K_(ⅡH)/K_(ⅡX) of HIC under mode Ⅱ load-ing was 0.27,which was nearly the same as that K(ⅠH)/K_(ⅠX)=0.29 under mode Ⅰ loading.While the thresholds of-HIC under(Ⅰ+Ⅱ)mixed mode loading were 0.36,0.41 and 0.37 cor-responding to the K_Ⅱ/K_Ⅰ ratio of 0.27,0.4 and O.81.The results show that simple mode Ⅰor mode Ⅱ loading is more susceptible to hydrogen embrittlement than(Ⅰ+Ⅱ)mixed mode.For explaining the experimental results,the effects of triaxial stress as well as plasticdeformation ahead of crack tip has been discussed.
|