Freeze Profile and Heat Balance Calculation of the 160kA Drained Cell
FREEZE PROFILE AND HEAT BALANCE CALCULATION OF THE 160kA DRAINED CELL

Keywords: drained cell,freeze profile,heat balance,finite element code
H-H电池
,ACD,热平衡,冷冻剖面,储能

Full-Text   Cite this paper   Add to My Lib

Abstract:

A 2D full cell thermo-electric model of 160kA drained cell was set up using finite element code to calculate its freeze profile, then the drained cell model was modified according to the freeze profile computed and its heat balance was calculated. Compared with that of a 160kA conventional Hall-Heroult cell (H-H cell), though the melts vol- ume of the drained cell reduced greatly, the whole heat loss from it didn't drop down apparently, and an analysis was presented in the paper. On the other hand, the anode- cathode distance (ACD) of a drained cell was much less than that of a H-H cell, so the voltage drop on it and heat produced decreased too, steps should be taken to keep a workable heat balance on a drained cell.