红外  2011 

Sulfur Dioxide Measurement System Based on Non-dispersive Infrared Gas Analysis Technique
基于非分散红外光谱吸收法的SO2检测系统研究

Keywords: infrared technique,non-dispersive infrared,gas detection,sulfur dioxide
红外技术
,非分散红外,气体检测,二氧化硫.

Full-Text   Cite this paper   Add to My Lib

Abstract:

The non-dispersive infrared gas analysis technique and its application in sulfur dioxide measurement are presented. The absorbance acquisition and concentration retrieval in non-dispersion sulfur dioxide analysis are analyzed. By taking the third-order polynomial as a fitting model, the calibration curve is obtained with the nonlinear least-square. The measurement accuracy of the system is analyzed and the measurement error less than 2 \% is derived. The result shows that the non-dispersive infrared technique can measure the sulfur dioxide accurately and it can also be used in the analysis of other gases.