Oxidation inhibition of sulfite in dual alkali FGD system
Oxidation inhibition of sulfite in dual alkali flue gas desulfurization system

Keywords: dual alkali,sodium sulfite,oxidation inhibition,sodium thiosulfate,system,flue gas desulfurization,alkali,dual,sulfite,inhibition efficiency,Pilot,consumption rate,experimental,results,activation energy,reaction order,sodium thiosulfate,presence,Sodium,effects,operating parameters,pH value,catalyst,concentration
氧化抑制
,亚硫酸盐,脱硫作用,环境保护

Full-Text   Cite this paper   Add to My Lib

Abstract:

A laboratory-scale well-mixed thermostatic reactor with continuously blasting air was used to investigate the oxidation inhibition of sulfite in dual alkali flue gas desulfurization (FGD) system. The effects of operating parameters such as pH value and catalyst concentration on the oxidation were studied. Sodium thiosulfate was used in the system, and was found that it significantly inhabited the sulfite oxidation. In the absence of catalyst, sodium thiosulfate at 12.67 mmol/L had an inhibition efficiency of approximately 98%. While in the presence of catalyst, sodium thiosulfate at 26.72 mmol/L had an inhibition efficiency less than 85.0%. The oxidation reaction order of sulfite in the sodium thiosulfate was determined to be -1.90 and -0.55 in the absence and presence of the catalyst, respectively. Apparent activation energy of oxidation inhibition was calculated to be 53.9 kJ/mol. Pilot tests showed that the consumption rate of thiosulfate agreed well with the laboratory-scale experimental results.