全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
环境科学  2003 

Bio-Contact Oxidation A/O Process Experiment on Guanting Reservior Water
官厅水库入库水生物接触A/O工艺试验

Keywords: Guanting Reservior,bio-contact oxidation A/O process,influent ammonia nitrogen loading
官厅水库
,生物接触A/O工艺,进水氨氮负荷

Full-Text   Cite this paper   Add to My Lib

Abstract:

The results of the experiments showed that biological contact A/O process had evident removal effect of contaminations such as COD, ammonia nitrogen in water entering into Guanting Reservior and could successfully resume the quality. Under the conditions that air supply flux(gas/ammonia nitrogen) was more than 0.1 L/mg and influent ammonia nitrogen loading was lower than 0.08 kg/(m3.d), effluent COD was steadily 30 mg/L around, ammonia nitrogen removal rate was higher than 60%, and TN removal rate was 1.0%-31.3%. The main control parameter was influent ammonia nitrogen loading, which was proposed to be lower than 0.08 kg/(m3.d).