环境科学 2001
The Application of Air-lift Loop Column Filling with Porous Carrier in Wastewater Treatment
|
Abstract:
An air lift loop reactor filling with porous carrier particles was utilized as aeration column. Experiments were carried out in wide operating conditions. The experimental results showed that in the range of gas flow rate from 0.117 to 0.156 m3/(min.m3), a higher efficiency of removal of ammonium-N was achieved, and when the gas flow rate was above 0.039 m3/(min.m3), the COD was completely degraded in about 1 h. The filling ratio of the porous carriers in the column was an important factor for the removal of C and N compounds, and a filling ratio of 15% was proved to be most suitable in the operation ranges. The experimental results also indicated that the effect of aeration temperature on the removal efficiency was significant and the highest efficiency was obtained at around 25 degrees C.