A modified procedure was developed for the measurement of the effective air exchange rate, which represents the relationship between the pollutants emitted from indoor sources and the residents’ level of exposure, by placing the dosers of tracer gas at locations that resemble indoor emission sources. To measure the 24-h-average effective air exchange rates in future surveys based on this procedure, a low-cost, easy-to-use perfluorocarbon tracer (PFT) doser with a stable dosing rate was developed by using double glass vials, a needle, a polyethylene-sintered filter, and a diffusion tube. Carbon molecular sieve cartridges and carbon disulfide (CS 2) were used for passive sampling and extraction of the tracer gas, respectively. Recovery efficiencies, sampling rates, and lower detection limits for 24-h sampling of hexafluorobenzene, octafluorotoluene, and perfluoroallylbenzene were 40% ± 3%, 72% ± 5%, and 84% ± 6%; 10.5 ± 1.1, 14.4 ± 1.4, and 12.2 ± 0.49 mL min ?1; and 0.20, 0.17, and 0.26 μg m –3, respectively.
References
[1]
Shinohara, N; Mizukoshi, A; Yanagisawa, Y. Identification of responsible volatile chemicals that induce hypersensitive reactions to multiple chemical sensitivity patients. J. Expo. Anal. Environ. Epidemiol?2004, 14, 84–91, doi:10.1038/sj.jea.7500303. 14726947
[2]
Yoshino, H. Sick house problem and residential environment: current situation and action. J Architect Build Sci?2002, 117, 8–11. (in Japanese).
[3]
Gilbert, NL; Guay, M; Gauvin, D; Dietz, RN; Chan, CC; Lévesque, B. Air change rate and concentration of formaldehyde in residential indoor air. Atmos. Environ?2008, 42, 2424–2428, doi:10.1016/j.atmosenv.2007.12.017.
[4]
Japanese Industrial Standards Committee. Method for Measuring Amount of Room Ventilation (Carbon Dioxide Method)—JIS A 1406; JISC: Tokyo, Japan, 1974.
[5]
The Standard for Measuring Ventilation Effectiveness by Using Tracer Gas; SHASE-S 116-2003; The Society of Heating, Air-Conditioning and Sanitary Engineering of Japan: Tokyo, Japan, 2004.
[6]
US Environmental Protection Agency. Determination of Air Exchange Rate in Indoor Air Using Tracer Gas; EPA Method IP-4B; EPA: Washington, DC, USA, 1990.
[7]
Dietz, R; Cote, E. Air infiltration measurements in a home using a convenient perfluorocarbon tracer technique. Environ. Int?1982, 8, 419–433, doi:10.1016/0160-4120(82)90060-5.
[8]
US Environmental Protection Agency. Determination of Air Exchange Rate in Indoor Air Using Perfluorocarbon tracer (PTF); EPA Method IP-4A; EPA: Washington, DC, USA, 1989.
[9]
Stymne, H; Boman, CA; Kronvall, J. Measuring ventilation rates in the Swedish housing stock. Build. Environ?1994, 29, 373–379, doi:10.1016/0360-1323(94)90037-X.
[10]
ISO. Indoor air—Part 8: Determination of local mean age of air in buildings for the characterizing ventilation conditions; ISO 16000-8; ISA: Geneva, Switzerland, 2007.
[11]
Batterman, S; Jia, CR; Hatzivasilis, G. Migration of volatile organic compounds from attached garages to residences: A major exposure source. Environ. Res?2007, 104, 224–240, doi:10.1016/j.envres.2007.01.008. 17350611
[12]
Dodson, RE; Levy, JI; Shine, JP; Spengler, JD; Bennett, DH. Multi-zonal air flow rates in residences in Boston, Massachusetts. Atmos. Environ?2007, 41, 3722–3727, doi:10.1016/j.atmosenv.2007.01.035.
[13]
?ie, L; Stymne, H; Boman, CA; Hellstrand, V. The ventilation rate of 344 Oslo residences. Indoor Air?1998, 8, 190–196, doi:10.1111/j.1600-0668.1998.t01-1-00006.x.
[14]
Uchiyama, S; Asai, M; Hasegawa, S. A sensitive diffusion sampler for the determination of volatile organic compounds in ambient air. Atmos. Environ?1999, 33, 1913–1920, doi:10.1016/S1352-2310(98)00208-8.