Predictors of Indoor Air Concentrations in Smoking and Non-Smoking Residences

DOI: 10.3390/ijerph7083080

Keywords: residential indoor air quality, exposure, sources

Full-Text   Cite this paper   Add to My Lib

Abstract:

Indoor concentrations of air pollutants (benzene, toluene, formaldehyde, acetaldehyde, acrolein, nitrogen dioxide, particulate matter, elemental carbon and ozone) were measured in residences in Regina, Saskatchewan, Canada. Data were collected in 106 homes in winter and 111 homes in summer of 2007, with 71 homes participating in both seasons. In addition, data for relative humidity, temperature, air exchange rates, housing characteristics and occupants’ activities during sampling were collected. Multiple linear regression analysis was used to construct season-specific models for the air pollutants. Where smoking was a major contributor to indoor concentrations, separate models were constructed for all homes and for those homes with no cigarette smoke exposure. The housing characteristics and occupants’ activities investigated in this study explained between 11% and 53% of the variability in indoor air pollutant concentrations, with ventilation, age of home and attached garage being important predictors for many pollutants.

References

[1]  Mitchell, CS; Zhang, J; Sigsgaard, T; Jantunen, M; Lioy, PJ; Samson, R; Karol, MH. Current state of the science: health effects and indoor environmental quality. Environ. Health Perspect?2007, 115, 958–964.
[2]  Viegi, G; Simoni, M; Scognamiglio, A; Baldacci, S; Pistelli, F; Carrozzi, L; Annesi-Maesano, I. Indoor air pollution and airway disease. Int. J. Tuberc. Lung Dis?2004, 8, 1401–1415.
[3]  Dales, R; Liu, L; Wheeler, AJ; Gilbert, NL. Quality of indoor residential air and health. Can. Med. Assoc. J?2008, 179, 147–152.
[4]  Klepeis, NE; Nelson, WC; Ott, WR; Robinson, JP; Tsang, AM; Switzer, P; Behar, JV; Hern, SC; Engelmann, WH. The National Human Activity Pattern Survey (NHAPS): a resource for assessing exposure to environmental pollutants. J. Expo. Anal. Environ. Epidemiol?2001, 11, 231–252.
[5]  Leech, JA; Nelson, WC; Burnett, RT; Aaron, S; Raizenne, ME. It’s about time: a comparison of Canadian and American time-activity patterns. J. Expo. Anal. Environ. Epidemiol?2001, 12, 427–432.
[6]  Stocco, C; MacNeill, M; Wang, D; Xu, X; Guay, M; Brook, J; Wheeler, AJ. Predicting personal exposure of Windsor, Ontario residents to volatile organic compounds using measurements and survey data. Atmos. Environ?2008, 42, 5905–5912.
[7]  Health Canada. Exposure Guidelines for Residential Indoor Air Quality—A Report of the Federal-Provincial Advisory Committee on Environmental and Occupational Health; Minister of Supply and Services Canada: Ottawa, Canada, 1987.
[8]  US, EPA. Human Exposure and Atmospheric Sciences Division. U.S. Environmental Protection Agency: Research Triangle Park, NC, USA, 1998.
[9]  Dietz, RN; Cote, EA. Air infiltration measurements in a home using a convenient perfluorocarbon tracer technique. Environ. Int?1982, 8, 419–433.
[10]  Health Canada. Proposed Residential Indoor Air Quality Guideline for Ozone. Canada Gazette, Part I, 4 April 2009, 143. Available online: http://gazette.gc.ca/rp-pr/p1/2009/2009-04-04/html/notice-avis-eng.html#d107/ (Accessed on 23 June 2010).
[11]  Allen, G; Sioutas, C; Koutrakis, P; Reiss, R; Lurmann, FW; Roberts, PT. Evaluation of the TEOM method for measurement of ambient particulate mass in urban areas. J. Air Waste Manag. Assoc?1997, 47, 682–689.
[12]  Cyrys, J; Gunnar, D; Kreyling, W; Tuch, T; Heinrich, J. PM2.5 measurements in ambient aerosol: comparison between Harvard impactor (HI) and the tapered element oscillating microbalance (TEOM) system. Sci. Total Environ?2001, 278, 191–197.
[13]  Fellin, P; Otson, R. Assessment of the influence of climatic factors on concentration levels of volatile organic compounds (VOCs) in Canadian homes. Atmos. Environ?1994, 28, 3581–3586.
[14]  Héroux, M-E; Gauvin, D; Gilbert, NL; Guay, M; Dupuis, G; Legris, M; Lévesque, B. Housing characteristics and indoor concentrations of selected volatile organic compounds (VOCs) in Quebec City, Canada. Indoor Built. Environ?2008, 17, 128–137.
[15]  Weisel, CP; Alimokhtari, S; Sanders, PF. Indoor air VOC concentrations in suburban and rural New Jersey. Environ. Sci. Technol?2008, 42, 8231–8238.
[16]  Zhu, J; Newhook, R; Marro, L; Chan, CC. Selected volatile organic compounds in residential air in the city of Ottawa, Canada. Environ. Sci. Technol?2005, 39, 3964–3971.
[17]  Batterman, S; Jia, C; Hatzivasilis, G. Migration of volatile organic compounds from attached garages to residences: a major exposure route. Environ. Res?2007, 104, 224–240.
[18]  Graham, LA; Noseworthy, L; Fugler, D; O’Leary, K; Karman, D; Grande, C. Contribution of vehicle emissions from an attached garage to residential indoor air pollution levels. J. Air Waste Manag. Assoc?2004, 54, 563–584.
[19]  Mann, HS; Crump, D; Brown, V. Personal exposure to benzene and the influence of attached and integrated garages. J. R. Soc. Promot. Health?2001, 121, 38–46.
[20]  Health Canada. Residential Indoor Air Quality Guideline: Formaldehyde; Her Majesty the Queen in Right of Canada, represented by the Minister of Health Canada: Ottawa, Canada, 2006.
[21]  Gilbert, NL; Gauvin, D; Guay, M; Héroux, M-E; Dupuis, G; Legris, M; Chan, CC; Dietz, RN; Lévesque, B. Housing characteristics and indoor concentrations of nitrogen dioxide and formaldehyde in Quebec City, Canada. Environ. Res?2006, 102, 1–8.
[22]  Bell, RW; Chapman, RE; Kruschel, BD; Spencer, MJ. Windsor Air Quality Study: Personal Exposure Survey Results; Queen’s Publisher for Ontario: Toronto, Canada, 1994.
[23]  Dingle, P; Franklin, P. Formaldehyde levels and the factors affecting these levels in homes in Perth, Western Australia. Indoor Built. Environ?2002, 11, 111–116.
[24]  Gilbert, NL; Guay, M; Miller, JD; Judek, S; Chan, CC; Dales, RE. Levels and determinants of formaldehyde, acetaldehyde, and acrolein in residential indoor air n Prince Edward Island, Canada. Environ. Res?2005, 99, 11–17.
[25]  Marchand, C; Bulliot, B; Le Calvé, S; Mirabel, Ph. Aldehyde measurements in indoor environments in Strasbourg (France). Atmos. Environ?2006, 40, 1336–1345.
[26]  Hun, DE; Corsi, RL; Morandi, MT; Siegel, JA. Formaldehyde in residences: long-term indoor concentrations and influencing factors. Indoor Air?2010, 20, 196–203.
[27]  Clarisse, B; Laurent, AM; Seta, N; Le Moullec, Y; El Hasnaoui, A; Momas, I. Indoor aldehydes : measurement of contamination levels and identification of their determinants in Paris dwellings. Environ. Res?2003, 92, 245–253.
[28]  Jurvelin, J; Vartiainen, M; Jantunen, M; Pasanen, P. Personal exposure levels and microenvironmental concentrations of formaldehyde and acetaldehyde in the Helsinki metropolitan area, Finland. Am. Air Waste Manage. Assoc?2001, 51, 17–24.
[29]  Kinney, PL; Chillrud, SN; Ramstrom, S; Ross, J; Spengler, JD. Exposures to multiple air toxics in New York City. Environ. Health Perspect?2002, 110, 539–546.
[30]  Ho, SSH; Yu, JZ; Chu, KW; Yeung, LL. Carbonyl emissions from commercial cooking sources in Hong Kong. J. Air Waste Manag. Assoc?2006, 56, 563–584.
[31]  Abt, E; Suh, HH; Allen, G; Koutrakis, P. Characterization of indoor particle sources: A study conducted in the metropolitan Boston area. Environ. Health Perspect?2000, 108, 35–44.
[32]  Adgate, JL; Ramachandran, G; Pratt, GC; Waller, LA; Sexton, K. Spatial and temporal variability in outdoor, indoor, and personal PM2.5 exposure. Atmos. Environ?2002, 36, 3255–3265.
[33]  Alberta Health and Wellness. The Alberta Oil Sands Community Exposure and Health Effects Assessment Program: Summary Report; Alberta Health and Wellness: Edmonton, Canada, 2000. Available online: http://www.health.alberta.ca/documents/Oil-sands-HEAP-Sum-2000.pdf/ (Accessed on 23 June 2010).
[34]  Keeler, GJ; Dvonch, JT; Yip, FY; Parker, EA; Israel, BA; Marsik, FJ; Morishita, M; Barres, JA; Robins, TG; Brakefield-Caldwell, W; Sam, M. Assessment of personal and community-level exposures to particulate matter among children with asthma in Detroit, Michigan, as part of Community Action Against Asthma (CAAA). Environ Health Perspect?2002, 110, 173–181.
[35]  Larson, T; Gould, T; Simpson, C; Liu, LJ; Claiborn, C; Lewtas, J. Source apportionment of indoor, outdoor, and personal PM2.5 in Seattle, Washington, using positive matrix factorization. J. Air Waste Manag. Assoc?2004, 54, 1175–1187.
[36]  Liu, L-S; Box, M; Kalman, D; Kaufman, J; Koenig, J; Larson, T; Lumley, T; Sheppard, L; Wallace, L. Exposure assessment of particulate matter for susceptible populations in Seattle. Environ. Health Perspect?2003, 111, 909–918.
[37]  Long, CM; Suh, HH; Koutrakis, P. Characterization of indoor particle sources using continuous mass and size monitors. J. Air Waste Manag. Assoc?2000, 50, 1236–1250.
[38]  Miller, JD; Dugandzic, R; Frescura, A-M; Salares, V. Indoor- and outdoor-derived contaminants in urban and rural homes in Ottawa, Ontario, Canada. J. Air Waste Manag. Assoc?2007, 57, 297–302.
[39]  Pang, Y; Gundel, LA; Larson, T; Finn, D; Liu, L-S; Claiborn, CS. Development and evaluation of a personal particulate organic and mass sampler. Environ. Sci. Technol?2002, 36, 5205–5210.
[40]  Pellizzari, ED; Clayton, CA; Rodes, CE; Mason, RE; Piper, LL; Fort, B; Pfeifer, G; Lynam, D. Particulate matter and manganese exposures in Toronto, Canada. Atmos. Environ?1999, 33, 721–734.
[41]  Ramachandran, G; Adgate, JL; Hill, N; Sexton, K; Pratt, GC; Bock, D. Comparison of short-term variations (15-minute averages) in outdoor and indoor PM2.5 concentrations. J. Air Waste Manag. Assoc?2000, 50, 1157–1166.
[42]  Ramachandran, G; Adgate, JL; Pratt, GC; Sexton, K. Characterizing indoor and outdoor 15 minute average PM2.5 concentrations in urban neighborhoods. Aerosol Sci. Technol?2003, 37, 33–45.
[43]  Rojas-Bracho, L; Suh, HH; Koutrakis, P. Relationships among personal, indoor, and outdoor fine and coarse particle concentrations for individuals with COPD. J. Exposure Anal. Environ. Epidemiol?2000, 10, 294–306.
[44]  Rojas-Bracho, L; Suh, HH; Catalano, PJ; Koutrakis, P. Personal Exposures to particles and their relationships with personal activities for chronic obstructive pulmonary disease patients living in boston. J. Air Waste Manag. Assoc?2004, 54, 207–217.
[45]  Sarnat, JA; Long, CM; Koutrakis, P; Coull, BA; Schwartz, J; Suh, HH. Using sulfur as a tracer of outdoor fine particulate matter. Environ. Sci. Technol?2002, 36, 5305–5314.
[46]  Fine, PM; Cass, GR; Simoneit, BRT. Characterization of fine particle emissions from burning church candles. Environ. Sci. Technol?1999, 33, 2352–2362.
[47]  He, C; Morawska, L; Hitchins, J; Gilbert, D. Contribution from indoor sources to particle number and mass concentrations in residential houses. Atmos. Environ?2004, 38, 3405–3415.
[48]  H?nninen, OO; Lebret, E; Ilacqua, V; Katsouyanni, K; Künzli, N; Sram, RJ; Jantunen, M. Infiltration of ambient PM2.5 and levels of indoor generated non-ETS PM2.5 in residences of four European cities. Atmos. Environ?2004, 38, 6411–6423.
[49]  Meng, QY; Turpin, BJ; Korn, L; Weisel, CP; Morandi, M; Colome, S; Zhang, J; Stock, T; Spektor, D; Winer, A; Zhang, L; Lee, JH; Giovanetti, R; Cui, W; Kwon, J; Alimokhtari, S; Shendell, D; Jones, J; Farrar, C; Maberti, S. Influence of ambient (outdoor) sources on residential indoor and personal PM2.5 concentrations: Analyses of RIOPA data. J. Expo. Anal. Environ. Epidemiol?2005, 15, 17–28.
[50]  Quintana, PJE; Valenzia, JR; Delfino, RJ; Liu, L-JS. Monitoring of 1-min personal particulate matter exposures in relation to voice-recorded time-activity data. Environ. Res?2001, 87, 199–213.
[51]  Evans, GJ; Peers, A; Sabaliauskas, K. Particle dose estimation from frying in residential settings. Indoor Air?2001, 18, 499–510.
[52]  Riley, WJ; McKone, TE; Lai, ACK; Nazaroff, WW. Indoor particulate matter of outdoor origin: importance of size-dependent removal mechanisms. Environ. Sci. Technol?2002, 36, 200–207.
[53]  Wallace, LA; Emmerich, SJ; Howard-Reed, C. Effect of central fans and in-duct filters on deposition rates of ultrafine and fine particles in an occupied townhouse. Atmos. Environ?2004, 38, 405–413.
[54]  Wood Buffalo Environmental Association. Human Exposure Monitoring Program, Part II—2005 Monitoring Year Results; Wood Buffalo Environmental Association: Alberta, Canada, 2007. Available online: http://wbea.org/content/view/34/208/ (Accessed on 23 June 2010).
[55]  Wood Buffalo Environmental Association. Human Exposure Monitoring Program—2006 Monitoring Year Results; Wood Buffalo Environmental Association: Alberta, Canada, 2008. Available online: http://wbea.org/content/view/34/208/ (Accessed on 23 June 2010).
[56]  Natural Resources Canada. 2007 Survey of Household Energy Use—Detailed Statistical Report; Her Majesty the Queen in Right of Canada: Ottawa, Canada, 2010; pp. 74–79.
[57]  Raw, GJ; Coward, SKD; Brown, VM; Crump, DR. Exposure to air pollutants in English homes. J Expo. Anal. Environ. Epidemiol?2004, 14, S85–S94.
[58]  Zota, A; Adamkiewicz, G; Levy, JI; Spengler, JD. Ventilation in public housing: implications for indoor nitrogen dioxide concentrations. Indoor Air?2004, 15, 393–401.
[59]  Rijnders, E; Janssen, NAH; van Vliet, PHN; Brunekreef, B. Personal and outdoor nitrogen dioxide concentrations in relation to degree of urbanization and traffic density. Environ. Health Perspect?2001, 109, 411–417.

Full-Text

Contact Us