Biosensors  2012 

Effect of Toxic Components on Microbial Fuel Cell-Polarization Curves and Estimation of the Type of Toxic Inhibition

DOI: 10.3390/bios2030255

Keywords: toxicity detection, microbial fuel cell, biosensor, least square estimation, linear regression

Full-Text   Cite this paper   Add to My Lib

Abstract:

Polarization curves are of paramount importance for the detection of toxic components in microbial fuel cell (MFC) based biosensors. In this study, polarization curves were made under non-toxic conditions and under toxic conditions after the addition of various concentrations of nickel, bentazon, sodiumdodecyl sulfate and potassium ferricyanide. The experimental polarization curves show that toxic components have an effect on the electrochemically active bacteria in the cell. (Extended) Butler Volmer Monod (BVM) models were used to describe the polarization curves of the MFC under nontoxic and toxic conditions. It was possible to properly fit the (extended) BVM models using linear regression techniques to the polarization curves and to distinguish between different types of kinetic inhibitions. For each of the toxic components, the value of the kinetic inhibition constant Ki was also estimated from the experimental data. The value of Ki indicates the sensitivity of the sensor for a specific component and thus can be used for the selection of the biosensor for a toxic component.

References

[1]  Franks, A.E.; Nevin, K.P. Microbial fuel cells, a current review. Energies 2010, 3, 899–919, doi:10.3390/en3050899.
[2]  Kim, M.; Hyun, M.S.; Gadd, G.M.; Kim, H.J. A novel biomonitoring system using microbial fuel cells. J. Environ. Monit. 2007, 9, 1323–1328, doi:10.1039/b713114c.
[3]  Logan, B.E.; Regan, J.M. Microbial fuel cells: Chalanges and applications. Environ. Sci. Technol. 2006, 40, 5172–5180, doi:10.1021/es0627592. 16999086
[4]  Chang, I.S.; Moon, H.; Jang, J.K.; Kim, B.H. Improvement of a microbial fuel cell performance as a BOD sensor using respiratory inhibitors. Biosens. Bioelectron. 2005, 20, 1856–1859, doi:10.1016/j.bios.2004.06.003.
[5]  Stein, N.E.; Hamelers, H.V.M.; Buisman, C.N.J. Stabilizing the baseline current of a microbial fuelcell-based biosensor through overpotential control under non-toxic conditions. Bioelectrochemistry 2010, 78, 87–91, doi:10.1016/j.bioelechem.2009.09.009.
[6]  Ter Heijne, A.; Hamelers, H.V.M.; Saakes, M.; Buisman, C.J.N. Performance of non-porous graphite and titanium based anodes in microbial fuel cells. Electrochim. Acta 2008, 53, 5697–5703, doi:10.1016/j.electacta.2008.03.032.
[7]  Kato Marcus, A.; Torres, C.I.; Rittmann, B.E. Conduction-based modeling of the biofilm anode of a microbial fuel cell. Biotechnol. Bioeng. 2007, 98, 1171–1182, doi:10.1002/bit.21533.
[8]  Torres, C.I.; Marcus, A.K.; Parameswaran, P.; Rittmann, B.E. Kinetic experiments for evaluating the nernst-monod model for Anode-Respiring Bacteria (ARB) in a biofilm anode. Environ. Sci. Technol. 2008, 42, 6593–6597, doi:10.1021/es800970w.
[9]  Hamelers, H.V.M.; Heijne, A.T.; Stein, N.E.; Rozendal, R.A.; Buisman, C.J.N. Butler-Volmer-Monod model for describing bio-anode polarization curves. Bioresour. Technol. 2011, 102, 381–387, doi:10.1016/j.biortech.2010.06.156. 20655743
[10]  Stein, N.E.; Keesman, K.J.; Hamelers, H.V.M.; van Straten, G. Kinetic models for detection of toxicity in a microbial fuel cell based biosensor. Biosens. Bioelectron. 2011, 26, 3115–3120, doi:10.1016/j.bios.2010.11.049.
[11]  Logan, B.E.; Regan, J.M. Electricity-producing bacterial communities in microbial fuel cells. Trends Microbiol. 2006, 14, 512–518, doi:10.1016/j.tim.2006.10.003.
[12]  Yoshida, N.; Hoashi, J.; Morita, T.; McNiven, S.J.; Nakamura, H.; Karube, I. Improvement of a mediator-type biochemical oxygen demand sensor for on-site measurement. J. Biotechnol. 2001, 88, 269–275, doi:10.1016/S0168-1656(01)00282-6. 11434972
[13]  Yoshida, N.; Yano, K.; Morita, T.; McNiven, S.J.; Nakamura, H.; Karube, I. A mediator-type biosensor as a new approach to biochemical oxygen demand estimation. Analyst 2000, 125, 2280–2284, doi:10.1039/b005995l. 11219067
[14]  Liu, C.; Sun, T.; Zhai, Y.; Dong, S. Evaluation of ferricyanide effects on microorganisms with multi-methods. Talanta 2009, 78, 613–617, doi:10.1016/j.talanta.2008.12.019.
[15]  Stein, N.E.; Hamelers, H.V.M.; Straten, G.V.; Keesman, K.J. On-line detection of toxic components using a microbial fuel cell-based biosensor. J. Process Control 2012. submitted.
[16]  Keesman, K.J. System Identification: An Introduction, 1st ed.; Springer Verlag: London, UK, 2011.
[17]  Montgomery, D.C.; Peck, E.A.; Vining, G.G. Introduction to Linear Regression Analysis; Wiley-Interscience: Hoboken, NJ, USA, 2006.
[18]  Doeswijk, T.G.; Keesman, K.J. Linear parameter estimation of rational biokinetic functions. Water Res. 2009, 43, 107–116, doi:10.1016/j.watres.2008.10.019.
[19]  Keesman, K.J.; Doeswijk, T.G. Direct least-squares estimation and prediction of rational systems: Application to food storage. J. Process Control 2009, 19, 340–348, doi:10.1016/j.jprocont.2008.03.006.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133